Aiphone LE-SSR Instructions Download Page 2

Aiphone Communication Systems
1700 130th Ave. N.E.
Bellevue, WA  98005
(425) 455-0510
FAX (425) 455-0071

Toll Free Technical Support:

1-800-692-0200

E-mail [email protected]

LE-SS(R,GP) Instr.

0909BKJS

SPECIFICATIONS:

Power Source:

Supplied by master station

Speaker:

20 ohms, 4W, 2.5" diameter, water proof and puncture resistant, 2.4 oz. magnet

Call Button:

SPST call button. Call tone rings at master as long as button is held down. LED will remain lit for approx. 
20 seconds (LEF, LEM-3, MP-3S, AP-5/10M only). Call tone only on LEM-1DL, LEM-1, and MP-1S.
LE-SS/-GP: Limited stop button. LE-SSR: Limited stop, red mushroom button

Communication:

Hands free at sub.  Master is push-to-talk,release-to-listen.

Faceplate:

12 gauge stainless steel

Mounting:

Flush mount into a 2-gang box. Surface mount into SBX-2G, sold separately.  Tamper proof screws 
included (6x32 for use with flush gang box) with T-10 TORX bit.
Use hardware included with SBX-2G when installing sub into that unit. 

Terminations:

Color-coded prewired pigtails

Operating Temperature:

Speaker rating: -67°F  to 187°F
LE-SS(G) Switch rating: 14 F to 158°F; LE-SSR Switch Rating: -22 F to 185°F

Wiring:

2 conductors in a 1-master LEF, MP-S, or AP-M system. 3 conductors in a multi-master LEF system.
Shielded cable is recommended.  Use Aiphone #822202 for LEM or MP-S. Use #822202 or 
#822203 for LEF. Use #832202 for AP-M systems.

Wiring Distance:

See system that unit is being used with for distance specifications.  

Dimensions (H x W x D):  LE-SS/-SSR/-GP alone:  4-11/16" x 4-11/16" x 2"

With SBX-2G(-GP2):  4-3/4" x 4-7/8" x 3-5/8" (Top) 2-3/8" (Bottom)

WIRING DIAGRAMS:

1

E

2

E

~

10

E

AP-M Master

Modifying LE-SS/-SSR/-GP 
to work with AP-M Master:

1. Cut Brown wire on CP038.   

(Brown wire jumpers J8 to J10.)

2. Tie Brown wire from J8 to 

Orange wire on J9.

3. Tie Brown wire from J10 to 

Yellow wire on J11.

Tie Blk and Grn wires together for all 
installations with the MP-S and AP-M 
systems.

Red

Blk

Grn

Brn

Org

Brn

Yel

Red

Blk

Grn

Brn

Org

Brn

Yel

LE-SS/LE-SSR

1

(2)
(3)

E

+

-

MP-S Master

+

-

PS-1225UL

MP-S SYSTEM:

AP-M SYSTEM:

WIRE DEFINITIONS:

Red:

Hot side of speaker & call switch, connect to # of master

Black: Common communication, connect to E of master
Green: Negative side of call switch
Brown: Call switch, left intact for LEM, LEF. 

Jumpered with Org/Yel for AP-M

Orange: Additional resistor circuit for AP-M
Yellow:  Additional resistor circuit for AP-M

LE-SS(R,-GP) Sub

Red

Blk*

Grn

LE-SS(R,-GP) Sub

Jumper Green & Black 
wires together. 
Leave brown, orange, 
and yellow wires 
disconnected.

Intercom wiring must be run at least 20" away from any AC wiring, fluorescent lighting, 
dimmer switches, or any other electronic device that may cause interference.