Aiphone IXW-HWCBP Instructions Download Page 2

The 

fi

 rst step is to enable the contact input on the IX Series door station will connect to the 

IXW-HWCBP. Open IX Support Tool and select the system to edit. Door stations can have up to 6 
contact inputs. These instructions will show using contact input 1. In the upper left corner of the screen 
click 

Station View

 to switch from 

Table View

 to 

Station View

Enabling Door Station Option Input

 1.1 - Option Input

Expand 

Option Input / Relay Output 

Settings

 and click 

Option Input

.

 1.2 - Select a Station

Use the drop-down menu or click 

Next

to choose the station number of the door 
station to be con

fi

 gured. Click 

Select

.

 1.3 - Option Input / Name

Select 

Option Input 1 

using the 

drop-down menu and assign a 

Name

.

 1.4 - Choose a Function

Select 

Call

 for this option input.

 1.5 - Contact Settings

Select 

Make

 for the 

Type 

and 

0 (Immediate)

 for the 

Detection Time 

Range

.

Click 

Update 

to 

save your settings.