2
INSTALLATION & MOUNTING
Installation Instructions:
1.
If the IPW-1A adaptor is not on the same LAN or
network segment as the PC master station, ensure
that the IPW-1A has been pre-programmed with the
proper connection settings prior to physical adaptor
installation. See the CommuniCenter Operations
manual (included on CD with IPW-1A).
2.
Wire the sub station to the proper connector on the
IPW-1A, and connect to the network using the
standard RJ-45 jack. Wiring from the sub station to
the IPW-1A should be a 2-conductor, shielded cable.
Connect the PT-1211C power supply included to the
power input connector.
Mounting Instructions:
1.
Mount the IPW-1A adaptor in a controlled area or in an enclosure suitable to
the installation environment. The IPW-1A chassis is
neither vandal resistant
nor weather resistant
. Secure the provided mounting bracket and then slide
the IPW-1A onto the bracket as shown. If mounting the unit on a shelf, attach
the 4 rubber feet that are included.
Pg. 2
Wiring to sub station should be 2-conductor shielded cable.
Wire distance from IPW-1A to IE series sub station:
22AWG = 387 feet, 18AWG = 980 feet
RESET
RS-232
STATUS
SUB
PT-1211C
SUB
1
2
Audio Only Door
IE Series sub station
LAN
PWR
POWER
PT
Note:
Contact rated at 30V, 1A.
1.
Load the software onto the PC to be used as a master station. Insert the CD (included with IPW-1A) or download the
latest version from the Aiphone website (www.aiphone.com).
2.
Install the CommuniCenter software by following the on-screen prompts,
or by executing “
setup.exe
” to begin the
installation process.
3.
IPW-1A adaptors within the same broadcast domain as the PC will appear in the sub station location list. Consult the
CommuniCenter Operation manual document for further software functionality and configuration information.
NOTE
– If installing system over a WAN please refer to the CommuniCenter Operation manual.
3
CommuniCenter SOFTWARE INSTALLATION
4-11/16"
4"
1-5/8"
*
IN0 IN1 NO C NC