SPECIFICATIONS:

Power Source:

Supplied by master station

Speaker:

Baffle protected, Water proof and puncture resistant, 2.4 oz. magnet

Microphone:

Baffle protected

Call Button:

SPST call button. Call tone is activated at master when call button is pressed
IE-SS/A: Limited stop button. IE-SSR: Limited stop, red mushroom button

Communication:

Hands free at sub.  Master uses handset.

Faceplate:

12 gauge stainless steel

Mounting:

Flush mount into a 2-gang box. Surface mount into SBX-2G, sold separately.  
Tamper proof screws included (6x32 for use with flush gang box) with T-10 TORX bit.
Use hardware included with SBX-2G when installing sub into that unit. 

Terminations:

Color-coded prewired pigtails

Operating Temperature:

Flush Switch rating: 14°F to 158°F; Mushroom Switch rating: -22°F to 185°F
Speaker rating: -67°F  to 187°F

Wiring:

2 conductors. Use Aiphone #822202

Wiring Distance:

See system that unit is being used with for distance specifications

Dimensions (H x W x D):  IE-SS/A / IE-SSR alone:  4-11/16" x 4-11/16" x 2"

With SBX-2G:  4-3/4" x 4-7/8" x 3-5/8" (Top) 2-3/8" (Bottom)

+

-

WIRING DIAGRAM (TD-H Series):

1*

~

24

C
D

+

-

TD-H Master

PS-1225UL

Red

Blk

IE-SS/A / IE-SSR

C

1
2

D

+

-

DE-UR

TD-H Masters:

TD-3H/B
TD-6H/B
TD-12H/B
TD-24H/B

NOTES:

1. The TD-1H/B does not have a “D” terminal for use with a door station. 
2. Max. two door stations can be used on the TD-H/B system, each requiring a DE-UR. Set A-B switch on 

each one to differentiate intermittent tremolo tone when doors call in.

2. Refer to the standard TD-H/B instructions for complete installation and wiring information.

~
~

1/D1

2/E1

+

-

IE-series

IE-SS/A / IE-SSR

PT-1210N

Red

Blk

IE Series 
2-door systems:

IE-2AD
IE-8MD

~
~

D1

E1

D2

E2

+

-

IE-series

IE-SS/A / IE-SSR

PT-1210N

Red

Blk

IE-SS/A / IE-SSR

Red

Blk

WIRING DIAGRAM (IE Series):

IE Series 
1-door systems:

IE-1AD (1 / 2)
IE-1GD (D1/E1)

* Connect to desired station number, 1 ~ 12.

TOLL FREE TECHNICAL SUPPORT:

(800) 692-0200

E-MAIL: [email protected]