Aiphone GTW-LC Installation And Operation Manual Download Page 8

- 8 -

  6 

SETTING UP

6-1

Setup tool

*  Completing settings with the setup tool is required.
1. Install the setup tool in the PC (Windows 7/VISTA/XP ®) beforehand, 

and then enter the resident information.

*  For details on the setup tool, refer to the GT Series Installation & Op-

eration Manual.

  Save programmed data and resident information data to your PC is rec-

ommended.

2. Connect the PC terminal of GT-BCX to the PC with USB cable (A-B 

type) (included with GT-NS(-V), GT-MK, GT-DM(V)).

*  PC requires USB output.
3. Start the setup tool (double-click gt_program.exe).
4. Select the system (GT or GH).
5. After inputting resident information and clicking OK, the  Lift Control 

1  tab and  Lift Control 2  tab will appear if  Lift Control  is selected 
in the  View  menu.

 If resident information is not input, the  Lift Control 1  tab and  Lift 

Control 2  tab will not appear.

GT-BCX

USB Cable (A-B type)

1

2

3

4

Summary of Contents for GTW-LC

Page 1: ...SERVICE MANUAL INSTALLATION OPERATION MANUAL 0311 A OI GTW LC GT System Lift control adaptor GTW LC...

Page 2: ...em If non speci ed product is used re or malfunction could result 5 Do not install the unit in any of the following locations Fire electric shock or unit trouble could result Places under direct sunli...

Page 3: ...Capacity Lift control adaptor Maximum 16 adaptors up to 8 adaptors per trunk Capacity of other units conform to the expanded system 1 2 Wiring Distance DP Distribution Point Diameter of wires 0 65 mm...

Page 4: ...4 2 CONTENTS 3 NAMES Contents Lift control adaptor GTW LC mounting bracket is included Names 1 Bus line terminal 2 ID setting switch 3 Relay output terminal 4 Lock release lever GTW LC 1 4 3 2 3...

Page 5: ...5 4 MOUNTING Mounting 1 Din rail 2 Lock release lever Mount GTW LC to the Din rail To remove GTW LC pull the lock release lever down GTW LC cannot be mounted directly to the wall surface GTW LC 1 2 1...

Page 6: ...xpanded System a ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 5 6 7 8 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 9 10 11 12 ON 1 2 3 4 ON 1 2 3 4 ON...

Page 7: ...Bus control unit GT BCX 2 Distribution terminal junction Not included 3 Lift control adaptor GTW LC Maximum 16 adaptors up to 8 adaptors per trunk ID ID setting switch factory setting is 1 Make sure...

Page 8: ...your PC is rec ommended 2 Connect the PC terminal of GT BCX to the PC with USB cable A B type included with GT NS V GT MK GT DM V PC requires USB output 3 Start the setup tool double click gt_program...

Page 9: ...box Input can be set by pressing the Enter key or by clicking inside of another Timer box 5 After GT system settings are completed the connected GTW LC ID numbers will display in black if the Check b...

Page 10: ...ance station that is in communication and the lift will begin to move The lift operates according to the lift controller settings In the cases below the lift will not move If the talk button is presse...

Page 11: ...a quali ed technician for service Speci cations Power supply Supplied by GT BC Relay contacts 20 AC DC 24 V 500mA N O N C dry closure operation time ac curacy 2 Wiring single pair cable Type of cable...

Page 12: ...d by the breakdown or malfunction of its products during use or for any consequent inconvenience or losses that may result This equipment has been tested and found to comply with the limits for a Clas...