5-3
CHAPTER 5. PC-CONTROLLED FUNCTIONS
2.3. Function Setting
(1) Group call setting
Registers the following contents designating the representative master station/telephone.
Contents
Setting Item
Member Station Exchange Number
Member Station line Number
Sets the exchange number (1
–
16) of the master station or telephone.
Sets the Line number (1
–
4) of the master station (telephone).
(2) Call forwarding & time-out settings
Registers the following contents designating the exchange number (1
–
16).
Contents
Setting Item
Call Forwarding
Enable/Disables the Call Forwarding function.
Time-Based Call Forwarding
Enables/Disables the Time-Based Call Forwarding function by its start
and end times.
Time-Based Call Forwarding Start
Time
Sets the hour and minute the call forwarding interval will begin. (00:00
–
23:59)
Time-Based Call Forwarding End
Time
Sets the hour and minute the call forwarding interval will end. (00:00
–
23:59)
Busy Call Forwarding
Enables/Disables the Busy Call Forwarding function.
No-Answer Call forwarding
Enables/Disables the No-Answer Call forwarding function. If enabled,
calls are transferred when no response is detected within the preset
interval.
Sets the station calling interval (1
–
99 seconds).
Call Time-Out
Enables/Disables the call time-out function. If enabled, calls are
terminated when no response is made within the preset interval.
Sets the station calling interval (1
–
99 minutes).
Conversation Time-Out
Enables/Disables the Conversation Time-Out function. If enabled,
conversations are automatically terminated when the time limit is
reached.
Sets the conversation time limit (10
–
990 seconds).
(3) Scan monitor setting
Registers the following contents designating the master station.
Contents
Setting Item
Monitoring Time
Sets the scan-monitor time interval (1
–
99 seconds).
Monitoring Substation Exchange
Number
Sets the number of the exchange to which the substation is connected
(1
–
16).
Monitoring Substation Line Number Sets the substation equipment number (1
–
64).
Monitoring Substation Number
Sets the substation number.
Monitoring Substation Name
Sets the substation name.
(4) Paging setting
Registers the substations assigned to the zone designating the exchange number (1
–
16).
Contents
Setting Item
Zone Number Digit
Selects the length of the digit to be used to label the paging zone
numbers (1
–
2).
Paging Time-Out
Enables/Disables the Paging Time-Out function.
Zone
Resisters substation numbers (1
–
1024) for each zone.
Sets a Paging time limit (10
–
990 seconds).