V 2.0 

 

 

SPECIFICATIONS 

 

MODEL 

PWRINV5K24012W 

DC Input Voltage 

12V 

Output Wave Form 

Modified Sine Wave 

Operating Voltage 

10V-16V 

Output Power 

5000 watts 220/230/240 VAC only single 
phase 60Hz (USA only) 

Surge Power Capacity 

10,000 for 40 mil secs 

Efficiency 

>90% 

No Load Current 

Switch on <1 A DC. Switch off <.2mA DC 

Fan 

Thermal 

Battery Low Alarm 

10.5V +/- .5V-1.5V 

Battery Low Shutdown 

10V +/- .5V-1.5V 

High Voltage Alarm 

17V +/- .5V 

Operating Temperature (Automatic 
Recovery/Shutdown) 

30-130°F 

Internal DC Input Fuse 

ATC Class 16 40 amp 

Mounting Hole Measurements 

3 holes - 2 3/8" center hole to center hole 

Remote Switch Port 

Yes 

Recommended Cable Size 

4/0 AWG 

Power Switch 

DC input ON/OFF 

AC Output Socket - 2 

240 Volt Single Phase ONLY (NO 110/120 
Volt) 

Dimensions (LxWxH) 

16.92 X 7.95 X 6.1 inches  

Net Weight 

16.72 lb 

 

Summary of Contents for PWRINV5K24012W

Page 1: ...V 2 0 DC TO AC POWER INVERTER PWRINV5K24012W Instruction Manual...

Page 2: ...r for remote homes off grid systems RVs boats commercial vehicles and mobile businesses The 5000 Watt 240 Volt AC 12 Volt DC inverter will operate most pumps motors and tools requiring 240V This inver...

Page 3: ...ttery voltage and current Current should be in the green zone for continuous operation The inverter will operate for several minutes when the current is in the yellow zone Operation with battery volta...

Page 4: ...t Red battery cable to Red battery terminal Connect Black battery cable to Black battery terminal Alligator clamp cables may be used but only to connect to the battery Do not use clamps on inverter te...

Page 5: ...air flow Ensure the ventilation openings on the rear and bottom of the unit are not obstructed d Safety Do not install the inverter in the same compartment as batteries or in any compartment capable...

Page 6: ...the chassis ground Therefore when the chassis is connected to ground the neutral conductor will also be grounded This conforms to national electrical code requirements that separately derived AC sourc...

Page 7: ...ion is possible with current in the orange area If the current rises to the red area the inverter will reduce its output voltage to protect itself 4 Over temp indicator The over temp indicator indicat...

Page 8: ...if the input voltage exceeds 17V 5V This protects the inverter against excessive input voltage The voltage indicator will be in the upper red zone Although the power inverter incorporates protection...

Page 9: ...ter switched off No power to the inverter Internal fuse open Reverse polarity Turn power switch to on position Check wiring to the inverter Check polarity No output voltage Voltage in upper red zone H...

Page 10: ...h off 2mA DC Fan Thermal Battery Low Alarm 10 5V 5V 1 5V Battery Low Shutdown 10V 5V 1 5V High Voltage Alarm 17V 5V Operating Temperature Automatic Recovery Shutdown 30 130 F Internal DC Input Fuse AT...