A.

 

On/Off switch: Leave in the OFF position during installation. 

B.

 

Over temperature indicator: Lights when inverter protects itself against overheating. Inverter 
shuts down while indicator is on. Inverter will restart automatically and indicator will turn off 
when the inverter cools. 

C.

 

Over load indicator: Lights when inverter shuts down because of overload. Indicator will turn off 
and inverter will restart when overload is removed. 

D.

 

Bar meters: 

Displays battery voltage and current. Current should be in the green zone for 

continuous operation. The inverter will operate for several minutes when the current is in the 
yellow zone. Operation with battery voltage or current in the red zone of a meter will result in 
protective shutdown of  inverter.

 

E.

 

AC outlets: 

Maximum recommended output per outlet is 1500W.

 

F.

 

Remote port: 

Used with remote switch to turn inverter ON/OFF (sold separately).

 

G.

 

AC terminal block: 

Hard wire block providing inverter's full power. 

 

 

 

 

 

 

 

 

 

E: AC outlets 

D: Bar meters 

B: Over temperature 
indicator 

A: On/Off 
switch  

C: Over load 
indicator 

G: AC terminal Block 

F: Remote port 

Summary of Contents for PWRINV500012W

Page 1: ...V 2 0 DC TO AC POWER INVERTER PWRINV500012W PWRINV500024W PWRINV500036W PWRINV500048W Instruction Manual...

Page 2: ...nician This item does not have any serviceable parts 7 Prevent body contact with grounded surfaces such as pipes radiators ranges and refrigerator enclosures during installation 8 Do not operate the i...

Page 3: ...ructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur It must be understood by the operator that common sense and caution are factors which c...

Page 4: ...oved D Bar meters Displays battery voltage and current Current should be in the green zone for continuous operation The inverter will operate for several minutes when the current is in the yellow zone...

Page 5: ...inverter terminal Connect Red battery cable to Red battery terminal Connect Black battery cable to Black battery terminal Alligator clamp cables may be used but only to connect to the battery Do not...

Page 6: ...er for air flow Ensure the ventilation openings on the rear and bottom of the unit are not obstructed d Safety Do not install the inverter in the same compartment as batteries or in any compartment ca...

Page 7: ...the chassis ground Therefore when the chassis is connected to ground the neutral conductor will also be grounded This conforms to national electrical code requirements that separately derived AC sourc...

Page 8: ...ion is possible with current in the orange area If the current rises to the red area the inverter will reduce its output voltage to protect itself 4 Over temp indicator The over temp indicator indicat...

Page 9: ...elow 10V or 20V or 30V or 40V 5V depending on model This protects your battery from being over discharged The power inverter will also shut down if the input voltage exceeds 17V 33V 46V 61V 5V This pr...

Page 10: ...ndicator in lower red zone Low input voltage Recharge battery Check cable connection No output voltage no voltage indication Inverter switched off No power to the inverter Internal fuse open Reverse p...

Page 11: ...rmal Battery Low Alarm 10 5V 5V 1 5V 21V 5V 1 5V 31 5V 5V 1 5V 42V 5V 1 5V Battery Low Shutdown 10V 5V 1 5V 20V 5V 1 5V 30V 5V 1 5V 40V 5V 1 5V High Voltage Alarm 17V 5V 33V 5V 46V 5V 61V 5V Operating...