Battery Use

 

 

 

 

To avoid over-discharging your vehicle battery, we recommend running your engine for 10-20 

minutes to recharge the vehicle's battery if battery voltage drops <11V. 

 

 

To properly size your battery, use the following formula: Volts * Amps = Watts or Watts/Volts 

= Amps. Example: 1000 watt inverter / 12 volts DC = 83.3 DC amps. In this example, you will 

need 83.3 amps to power a 1000 watt load for 1 hour. If you need to power 1000 watts for 2 

hours you will need 83.3 * 2 = 166.66 DC amps available. A 100 amp hour battery will give 

you 100 amps / 166.66 = .6 hours so you will need two batteries if using 100 amp battery. 

This is if you fully deplete your batteries. We do NOT recommend fully depleting your 

batteries. This is just an example. Your power requirements may be different. 

 

 

If you choose to use a female 12 Volt DC adapter for your inverter or to the inverter make 

sure wire size is correct. 

 

 

IF YOU CONNECT THE WIRES TO THE INCORRECT TERMINALS, YOU WILL REVERSE THE 

POLARITY AND DAMAGE THE INVERTER.                             

 

 

REVERSED POLAR ITY WILL INSTANTLY VOID THE WARRANTY OF YOUR INVERTER, SO BE 

CAREFUL TO CONNECT YOUR INPUT WIRES PROPEPLY.

 

 

If you choose to operate a battery charger to replenish your battery’s voltage, be sure to 

check with charger manufacture before damaging the charger. 

 

 

CONNECTING THE INVERTER’S DC INPUT TO A BATTERY CHARGER WILL VOID THE WARRANTY, 

AND MAY DAMAGE THE INVERTER.

 

 

Make sure that the battery voltage does not exceed 15 volts DC.

 

 

CONNECTING THE INVERTER TO A DC POWER SOURCE GREATER THAN 15 VDC WILL VOID 

THE WARRANTY, AND MAY DAMAGE THE INVERTER.

 

 
Cables 

We recommend that you refrain from using battery cables longer than 12 feet 

between the DC power source and the DC input of the inverter. Longer battery cables 

on the DC input will create a voltage drop which results in a reduction of efficiency 

and output. If you require more than 12 feet, use a bigger cable. We recommend 

using an extension cord between the AC output and AC appliance. You may use up to 

100ft, high quality extension cord. A longer cord may result in reduced output. See 

Specifications chart for recommended battery cable size. 

 

 

Measuring  The  AC  Voltage

 

The output waveform of the inverter is a MODIFIED SINE WAVE. If you choose to 

measure the AC output voltage, you must use a TRUE RMS MULTI METER. Using any 

Summary of Contents for PWRB2500W

Page 1: ...DC TO AC POWER INVERTER PWRB2500W INSTRUCTION MANUAL ...

Page 2: ...tery terminal Connect Black battery cable to Black battery terminal Alligator clamp cables may be used but only to connect to the battery Do not use clamps on inverter terminals Alligator clamps are not a permanent solution You may see a spark during connection Connect the ground cable to an earth ground such as a metal water pipe or to the vehicle ground when used in a vehicle if the inverter inc...

Page 3: ...ze the inverter properly Size the inverter for the surge rating of your equipment The inverter s continuous rating should be MORE than the surge rating of your equipment Example Power tool runs at 1500 watts but surges at 2500 watts You should use an inverter 3000 watts Keep the inverter well ventilated Do not place any objects on top of or next to the inverter or allow anything to cover the cooli...

Page 4: ...RANTY OF YOUR INVERTER SO BE CAREFUL TO CONNECT YOUR INPUT WIRES PROPEPLY If you choose to operate a battery charger to replenish your battery s voltage be sure to check with charger manufacture before damaging the charger CONNECTING THE INVERTER S DC INPUT TO A BATTERY CHARGER WILL VOID THE WARRANTY AND MAY DAMAGE THE INVERTER Make sure that the battery voltage does not exceed 15 volts DC CONNECT...

Page 5: ...of the unit makes it an electrical shock hazard if operated with wet hands Allow at least 12 inches of clearance around the Inverter for air flow Ensure the ventilation openings on the rear and bottom of the unit are not obstructed Do not connect the inverter directly to another AC power source Damage may result and such damage will void the inverter warranty Know the wattage requirements of your ...

Page 6: ...loads for extended period the inverter will shut down to prevent damage from excess heat Simply reduce your load and allow the Inverter to cool down Low battery shutdown Recharge your battery and resume operation MAINTENANCE Very little maintenance is required to keep your inverter operating properly You should disconnect input power first and then clean the exterior of the unit periodically with ...

Page 7: ...Battery Low Alarm DC 10 5 _ 0 5 V Battery Low Shutdown DC 9 5 _ 0 5 V Operating Temperature Automatic Recovery Shutdown 30 130 F Fan Always on Internal DC Input Fuse Must be fitted use 40A 8 max Remote Switch Port No Recommended Cable Size 1 0 AWG Power Switch DC input ON OFF control AC Output Socket Mounting Hole Location 4 7 8 center hole to center hole Dimensions LxWxH 14 65 x 6 6 x 3 14 Net We...

Page 8: ...stomer Except as provided above AIMS makes no warranty of any kind express or implied including without limitation the implied warranties of merchantability and fitness for a particular purpose In no event shall AIMS be liable for indirect special or consequential damages This warranty only applies to AIMS Power branded products All other name brand products are warranted by and according to their...

Reviews: