background image

 

AMC825 Hardware Manual  

 

GmbH

 

HARDWARE INSTALLATION 

 

Danger! 
Electric shock risk. Never carry out work while power supply voltage is switched 
on! 

 

 

Attention ! 
Electrostatic discharges may cause damage to electronic components. To avoid 
this, please perform the following steps before you touch the module, in order to 
discharge the static electricity from your body: 

 

Switch off the power of your computer, but leave it connected to the mains until 
you have discharged yourself.  
 
Please touch the metal case of the computer now to discharge yourself. 
 
Furthermore, you should prevent your clothes from touching the computer, because 
your clothes might be electro statically charged as well. 

 
 

Procedure: 

1.

 

Switch off your computer and all connected peripheral devices (monitor, printer, etc.). 

2.

 

Discharge your body as described above. 

3.

 

Disconnect the computer from the mains.  
If the computer does not have a flexible mains cable, but is directly connected to mains, 
disconnect the power supply via the safety fuse and make sure that the fuse cannot switch 
on again unintentionally (i.e. with caution label). 

4.

 

Open the case. 

5.

 

A conductive O-ring is contained in the product package of the module. Mount the 
conductive O-ring on the front panel of the to obtain EMC shielding.  

6.

 

Remove the carrier board (if already installed) and plug the carefully on the carrier board. 
Pay attention that the PMC module is correctly installed on the carrier board. 

7.

 

Fix the with the screws on the carrier board. Use the four M 2.5 x 6 mm screws which are 
contained in the product package of the module. 

8.

 

Install the carrier board in your system. 

9.

 

Close the computer case again. 

10.

 

Connect the CAN interfaces and the IRIG-B via the DSUB25 connector in the front panel 
of the AMC825-2/4. 

11.

 

Connect the computer to mains again (mains connector or safety fuse). 

12.

 

Switch on the computer and the peripheral devices. 

13.

 

End of hardware installation. 

14.

 

Set the interface properties in your operating system. Refer to the documentation of the 
operating system. 

Summary of Contents for ARINC825

Page 1: ...al AMC825 2 4 ARINC825 Test and Simulation Card Set for PMC AIM GmbH Sasbacher Str 2 79111 Freiburg Germany Tel 49 761 45229 0 Fax 49 761 45229 33 sales aim online com www aim online com November 2012...

Page 2: ......

Page 3: ...i GmbH GmbH AMC825 2 4 Hardware Manual ARINC825 Test and Simulation Card Set for PMC V01 01 Rev A November 2012 AIM No 60 19A1x 16 0101 A...

Page 4: ...19053 267 982 2600 877 520 1553 salesusa aim online com AIM UK Cressex Business Park Lincoln Rd High Wycombe Bucks HP12 3RB England 44 1494 44 68 44 salesuk aim online com Notice The information that...

Page 5: ...iii GmbH GmbH DOCUMENT HISTORY Version Cover Date Created by Description V01 00 A 01 02 2011 M Maier First Release V01 01 A 02 11 2012 M Maier Removed Chapter 2 2 3 ff...

Page 6: ...iv GmbH GmbH THIS PAGE INTENTIONALLY LEFT BLANK...

Page 7: ...ECIFIC AIM DOCUMENTS 2 2 HARDWARE INSTALLATION 3 2 1 CONNECTING TO OTHER DEVICES 4 2 1 1 AMC825 2 4 PCB VIEW 4 2 1 2 LEDS 5 2 2 CONNECTOR ASSIGNMENT 6 2 2 1 I O CONNECTOR X400 DSUB25 MALE PIN ASSIGNME...

Page 8: ...vi GmbH GmbH THIS PAGE INTENTIONALLY LEFT BLANK...

Page 9: ...IG B PMC Front Panel A D Converter 6 LEDs Block Diagram of Standard PMC CAN 400 4 Order No C 2047 01 optional FPGA IO The AMC825 features four electrically isolated CAN High Speed interfaces according...

Page 10: ...ion 2 INSTALLATION describes the steps required to install the AMC825 2 4 device and connect the device to other external interfaces Section 3 TECHNICAL DATA describes the technical specification of t...

Page 11: ...cable but is directly connected to mains disconnect the power supply via the safety fuse and make sure that the fuse cannot switch on again unintentionally i e with caution label 4 Open the case 5 A c...

Page 12: ...4 AMC825 Hardware Manual GmbH 2 1 Connecting to Other Devices 2 1 1 AMC825 2 4 PCB View...

Page 13: ...825 2 4 is equipped with 6 green LEDs in the front panel LED Function Indication LED on R RUN Board FPGA booted I IRIG B IRIG B Link 1 CAN1 Traffic on CAN Line 1 2 CAN2 Traffic on CAN Line 2 3 CAN3 Tr...

Page 14: ...9 CAN3_H CAN3_GND 7 20 8 21 CAN4_L CAN4_H 9 22 CAN4_GND 10 23 11 24 IRIG B_RX IRIG B_RX 12 25 IRIG B_A IRIG B_A 13 Description of Signals at X400 Name Description This pin is not connected at the modu...

Page 15: ...ctors The module uses the PMC connectors Pn1 Pn2 and Pn4 Pn1 and Pn2 provide the PCI interface and power supply connection Pn1 and Pn2 are according to PMC specification Pn4 is not used at this module...

Page 16: ...8 AMC825 Hardware Manual GmbH This page intentionally left blank...

Page 17: ...ed 20 75 C on request Conduction Cooled Ask factory for availability Humidity max 90 non condensing Dimensions 74 0 mm x 149 0 mm single PMC size Weight AMC825 81 g 3 2 PCI Bus Host bus PCI Bus accord...

Page 18: ...0 DSUB25 male 3 4 IRIG B Input Input decoder analogue coding IRIG B120 B123 IEEE1344 1995 isolating transformer 12 bit A D converter connector X400 DSUB25 male Input digital RS 422 compatible coding I...

Page 19: ...eers IRIG Inter Range Instrumentations Group IRIG B Inter Range Instrumentations Group Time code Format Type B LCA Logic Cell Array XILINX Programmable Gate Array LED Light emitting Diode MAC Media Ac...

Reviews: