background image

 

 

VII. Safe Operation and Maintenance 

Do not connect relay, extension cord or adaptor with this machine. 

Otherwise, fire, electric shock and heating can be caused. 

Do not place it near to equipments give heat such as furnace and heater. 

Otherwise, the resin may be melted and causes fire. 

Do not use this dehumidifier in places with direct sunlight or exposed to wind and 

rain. 

This machine is for indoor use only. 

When there is any abnormity (smell of burnt), please shut off the machine and 

unload the power  cord. 

Otherwise, fire, electric shock and new failures may be caused. 

Do not use this dehumidificr in places exposed to chemicals. 

The chemicals and solvent in the air may bring adverse effect to the machine and 

result in leakage in water tank. 

If the machine is spared for a long time, please unload the power cord. 

When clearing the machine, stop it first and unload the power cord. 

Otherwise, human injury may be caused. 

During continuous drainage, please place the drain pipe appropriately for smooth 

drainage. 

If  there  is  any  possibility  that  temperature  around  pipe  may  result  in  icing, 

continuous water drain is not allowed. 

Do not repair, disassemble or alternate  the machine  without authorization so as 

to avoid fire or electric shock accidents; 

Please place the machine in firm places; 

If the machine falls down, the water in water tank may leak out and damages stuff 

around and results in creepage and cause fire or electric shock accidents; 

Knacks to extend the service life of air purification filter mesh:  . 

If to be spared for a long time, keep the air purification  filter mesh in plastic bag 

and save hermetically. 

Do not use dehumidifier in places that may be exposed to water. 

There may be creepage if there is water and result in fire or electric shock. 

Please  use  proper  switch.  Otherwise,  fire  or  electric  shock  accidents  may  be 

caused. Do not damage or alternate the power cord. 

Do not place heavy things on power cord or heat up or pull forcefully the power 

cord,  otherwise  power  cord  may  be  damaged  and  causes  fire  or  electric  shock 
accidents. 

Please connect the power cord firmly with the switch. 

 If the power cord is loose, there may be risk of electric  shock. 

Do not stop operation of dehumidifier by pulling out the power cord. 

Summary of Contents for AD-1500B

Page 1: ......

Page 2: ......

Page 3: ...sed and narrow room Please keep this manual safely Note We advice that any repair should be carried out by professionals II Introduction to Product Dehumidifier is able to reduce air humidity of the space leaving people to live work and store goods in comfortable environment Dehumidifier of our company possesses such advantages of nice appearance compact structure and easy operation It is widely a...

Page 4: ...y to decrease the set humidity Buzzer buzzes once for each pressing and the set humidity decreases by 1 RH Pressthis button todecrease the presettingtime each pressing and the time d by 1 hour 1 Display range for humidity is 5 98 2 Auto detection of temperature humidity failure a When the system detects that temperature sensor exceeds the limited range the system enters mode of temperature sensor ...

Page 5: ...ration it will operate the mode of preset stop time The setting hours range is 0 24hours e Press Time button for 10s it display F1 it s humidity correction Press Time button for successively twice it displays F2 it s defrost interval time default 30 minutes Press Time button for successively three times Is displays F3 it s defrost time default 8 minutes Press Time button for successively four time...

Page 6: ...is any possibility that temperature around pipe may result in icing continuous water drain is not allowed Do not repair disassemble or alternate the machine without authorization so as to avoid fire or electric shock accidents Please place the machine in firm places If the machine falls down the water in water tank may leak out and damages stuff around and results in creepage and cause fire or ele...

Page 7: ...5 Otherwise fire or electric shock accident may be caused VIII Electrical wiring diagram IX Unit Dimension ...

Page 8: ...ication filter mesh may impair its effect or even cause failure Please clear regularly for at least once a month If there is much dust in the environment it must be cleared once a week or once a day Pull does the front panel clear the filter mesh Tap the filter mesh slightly or eliminate the dust by vacuum cleaner or place the mesh in warm water 40oC and addappropriate neutral scour and brush and ...

Page 9: ...ve the blocking object 3 Close the door and window 4 Contact with distributor or manufacturer for repair Water leak 1 The machine in inclined 2 Water pipe is blocked 1 Level the machine 2 Remove the blocking object Abnormal noise 1 The machine is not placed solidly 2 The filter mesh is blocked 1 Place the machine firmly 2 Clear the filter mesh a Where the above troubles cannot be fixed and repair ...

Page 10: ...capacity 30oC 80 138 L Day Rated input power 1450 W Air Circulation 1300 m3 h Compressor Aikyo Refrigerant Charge R410A 930g Suction pressure 2 5 MPa Discharge pressure 4 0 MPa Weight 52 kg Unit size 480 415 1065 mm The above parameters are subject to change without serving notice ...

Page 11: ...amage caused by transportation or handling Customer replaces disassembles and changes machine number without authorization 3 Damage caused by such natural disaster as lightning strike water disaster and Fire 4 Damage caused by use of power with abnormal voltage or power supplied by non power supplying department 5 Where the warranty card is lost reproduced or there is no invoice or no voucher of p...

Page 12: ......

Reviews: