Make sure to use only shielded cables whether balanced or unbalanced. Shielding when properly grounded protects a signal against
external radio interference, interference generated by dimmers and other electric noise. Avoid placing input cables close to power
cords or power transformers.
As a rule, unbalanced lines of over 3 meters long are not acceptable. Greater distances require a balanced cable.
Unbalanced connection models with XLR input connectors, contact 3 (Cold "-" ) need to be mutually connected with base contact 1
(Ground)
SPECIFICATION
TITLE
SUB PF118
SUB MP112
SUB MP115
Output power
1400W (8 Ohm, 230V)
700W (8 Ohm, 230V)
700W (8 Ohm, 230V)
Sensitivity
98dB 1 W/m
96dB 1 W/m
96dB 1 W/m
Maximal musical
pressure
130d
B
128d
B
128d
B
Built-in amplifier
Class D
Class D
Class D
Total harmonic
distortion
0,05% (45 Hz- 20 kHz, 8 Ohm) 0,05% (45 Hz- 20 kHz, 8 Ohm) 0,05% (45 Hz- 20 kHz, 8 Ohm)
Input connectors
2x female XLR
2x male XLR
2x female XLR
2x male XLR
2x female XLR
2x male XLR
Input sensitivity
0,775V (RMS)
0,775V (RMS)
0,775V (RMS)
Input impedance
10k Ohm (symmetric)
10k Ohm (symmetric)
10k Ohm (symmetric)
Frequency range
45Hz- 80...250 Hz
45Hz- 80...250 Hz
45Hz- 80...250 Hz
Filter
24dB/Oct
24dB/Oct
24dB/Oct
Components
1xFaital 18FH1060 8 Ohm
1xFaital 12FH500 8 Ohm
1xFaital 15FH500 8 Ohm
Corps material
18 mm Baltic birch plywood
18 mm Baltic birch plywood
18 mm Baltic birch plywood
Material
Black structured color
Black structured color
Black structured color
Dimensions (WxHxD)
540x605x670mm
390x460x590 mm
450x500x615mm
Weight
44kg
24kg
34kg
CONTROLS AND CONNECTORS
1 POWER
. power switch.
2 MAINS IN
. power cable socket.
ATTENTION! The power to the amplifier is supplied from single-
phase AC power mains
with protective grounding. To connect the amplifier to awall outlet,
first insert the power
cord into the power cord socket and then plug it into the wall outlet.
3
Channel B line output (XLR male): parallel to Channel B input.
4
Channel A line output (XLR male): parallel to Channel A input.
5
Channel A input (XLR female)*.
6
Channel B input (XLR female) *.
7 LOW PASS FILTER
. low-pass filter cutoff point knob: sets the
bandwidth upper
frequency (80Hz ... 350Hz).
8 BASS LEVEL
. input level control knob.
Used to adjust the level of the input signal applied to the power
amplifier.
9 CLIP / THERM
. overload/ thermal protection LED
Indicating:
. overload condition characterized by sound distortion and
optoelectronic clip-limiter
active mode; thermal protection active condition. (See: Thermal
Protection above).
10 POWER
LED.
In case of active DC protection system, the LED goes off.
11 PHASE
. output signal phase slide switch. Used to set the
required phase of the output
signal:
.
+
. signal phase unchanged;
.
.
. signal phase 180° reversed.