Make sure to use only shielded cables whether balanced or unbalanced. Shielding when properly grounded protects a signal against
external radio interference, interference generated by dimmers and other electric noise. Avoid placing input cables close to power
cords or power transformers.
As a rule, unbalanced lines of over 3 meters long are not acceptable. Greater distances require a balanced cable.
Unbalanced connection models with XLR input connectors, contact 3 (Cold "-" ) need to be mutually connected with base contact 1
(Ground)

SPECIFICATION

TITLE

SUB PF118

SUB MP112

SUB MP115

Output power

1400W (8 Ohm, 230V)

700W (8 Ohm, 230V)

700W (8 Ohm, 230V)

Sensitivity

98dB 1 W/m

96dB 1 W/m

96dB 1 W/m

Maximal musical

pressure

130d

B

128d

B

128d

B

Built-in amplifier

Class D

Class D

Class D

Total harmonic

distortion

0,05% (45 Hz- 20 kHz, 8 Ohm) 0,05% (45 Hz- 20 kHz, 8 Ohm) 0,05% (45 Hz- 20 kHz, 8 Ohm)

Input connectors

2x female XLR

2x male XLR

2x female XLR

2x male XLR

2x female XLR

2x male XLR

Input sensitivity

0,775V (RMS)

0,775V (RMS)

0,775V (RMS)

Input impedance

10k Ohm (symmetric)

10k Ohm (symmetric)

10k Ohm (symmetric)

Frequency range

45Hz- 80...250 Hz

45Hz- 80...250 Hz

45Hz- 80...250 Hz

Filter

24dB/Oct

24dB/Oct

24dB/Oct

Components

1xFaital 18FH1060 8 Ohm

1xFaital 12FH500 8 Ohm

1xFaital 15FH500 8 Ohm

Corps material

18 mm Baltic birch plywood

18 mm Baltic birch plywood

18 mm Baltic birch plywood

Material

Black structured color

Black structured color

Black structured color

Dimensions (WxHxD)

540x605x670mm

390x460x590 mm 

450x500x615mm

Weight

44kg

24kg

34kg

CONTROLS AND CONNECTORS

1 POWER 

. power switch.

2 MAINS IN 

. power cable socket.

ATTENTION! The power to the amplifier is supplied from single-
phase AC power mains
with protective grounding. To connect the amplifier to awall outlet, 
first insert the power
cord into the power cord socket and then plug it into the wall outlet.

3

 Channel B line output (XLR male): parallel to Channel B input.

4

 Channel A line output (XLR male): parallel to Channel A input.

Channel A input (XLR female)*.

Channel B input (XLR female) *.

7 LOW PASS FILTER 

. low-pass filter cutoff point knob: sets the 

bandwidth upper
frequency (80Hz ... 350Hz).

8 BASS LEVEL 

. input level control knob.

Used to adjust the level of the input signal applied to the power 
amplifier.

9 CLIP / THERM

. overload/ thermal protection LED

Indicating:
. overload condition characterized by sound distortion and 
optoelectronic clip-limiter
active mode; thermal protection active condition. (See: Thermal 
Protection above).

10 POWER

LED.

In case of active DC protection system, the LED goes off.

11 PHASE 

. output signal phase slide switch. Used to set the 

required phase of the output
signal:

. signal phase unchanged;

. signal phase 180° reversed.