![Aigis Mechtronics MLAR Fixed Focal Series Installation And Operating Instructions Manual Download Page 10](http://html1.mh-extra.com/html/aigis-mechtronics/mlar-fixed-focal-series/mlar-fixed-focal-series_installation-and-operating-instructions-manual_2871470010.webp)
Figure 6 Camera Assembly
6.1.2 Dip Switch Location and Settings
See
Detail B
for dip switch information.
Figure 7 Dip Switch Location
10
6. CAMERA AND LENS SETTINGS
6.1 MLAR VariFocal Series
The Camera module has various settings for any additional adjustments that
may be required. See
Figure 6 and 7
for adjustment locations.
6.1.1 Phase Adjust
The phase adjust control is located on the power board next to the power
cable connections (see
Figure 6
).To adjust phase, use a small screwdriver to
rotate control (blue block with yellow screw hole) until picture is
synchronized with other cameras in the system.
See
Detail A
Scale 3.x
Phase Adjust
Detail A
Phase Adjust Pot
See
Detail B