7.

 

 

MESSAGE

 

DISPLAY

 

 

Alarm

 

messages

 

from

 

the

 

Touchsafe

 

Pro

 

Nursecall

 

system

 

are

 

displayed

 

automatically.

 

Up

 

to

 

four

 

messages

 

are

 

stored

 

in

 

the

 

Pager,

 

as

 

new

 

messages

 

are

 

received

 

the

 

oldest

 

message

 

is

 

deleted

 

automatically.

 

 

On

 

receipt

 

of

 

a

 

message

 

the

 

Pager

 

will

 

beep

 

for

 

5

 

seconds

 

and

 

show

 

the

 

call

 

type

 

and

 

unit

 

ID

 

as

 

a

 

6

 

character

 

code

 

(e.g.

 

EME038)

 

followed

 

by

 

a

 

text

 

message

 

of

 

up

 

to

 

24

 

characters

 

to

 

identify

 

the

 

location.

 

   
 

 

 

 
 
 
 
 
 
 
 
 
 
 

After

 

5

 

seconds

 

the

 

display

 

will

 

revert

 

to

 

the

 

standby

 

screen

 

with

 

the

 

message

 

on

 

the

 

second

 

line;

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

To

 

review

 

the

 

stored

 

messages

 

in

 

rotation

 

repeatedly

 

press

 

the

        

Scroll

 

button…

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

      

 EME038 Daisy Ward  

 

 

 Bedroom 038

 

The

 

example

 

EME038

 

shows

 

an

 

Emergency

 

Call

 

from

 

unit

 

ID

 

038

 

which

 

is

 

in

 

Daisy

 

Ward

 

Bedroom

 

38.

 

Other

 

possible

 

call

 

types

 

are

 

listed

 

below;

 

Code

 

Call

 

Type

 

CAL038

 

Call

 

from

 

unit

 

ID

 

038

 

NUR038

Nurse

 

Present

 

at

 

unit

 

ID

 

038

 

ASS038

 

Assistance

 

Call

 

from

 

unit

 

ID

 

038

 

EME038

Emergency

 

Call

 

from

 

unit

 

ID

 

038

CAR038

 

Cardiac

 

Call

 

from

 

unit

 

ID

 

038

 

BED038

 

Bed

 

to

 

be

 

Cleaned

 

at

 

unit

 

ID

 

038

 

CAN038

 

Call

 

Cancelled

 

at

 

unit

 

ID

 

038

 

 

      

   ID101  M2  L00R    

  

 EME038 Daisy Ward

 

M2

 

indicates

 

the

 

number

 

of

 

stored

 

messages

 

(maximum

 

4).

 

 

      

 CAL003 Poppy Ward 

  

 Bedroom 003      04

 

04

 

indicates

 

the

 

elapsed

 

time

 

since

 

receiving

 

the

 

stored

 

message

 

(in

 

minutes).

 

Summary of Contents for Touchsafe Pro Bluebell

Page 1: ...continual product improvement and reserves the right to modify the specification of its products If any variation to the details in this document are suspected please contact Aidcall s Technical Support Aidcall a business unit of Legrand Electric Ltd Cowley Road Blyth Riverside Business Park Blyth Northumberland NE24 5TF T 44 0 1670 357 431 www aidcall co uk _______________________________________...

Page 2: ...are reported to the Pagers can be set along with the beep pattern to identify different call types Furthermore Pagers can be configured into zones so calls are only notified to the staff responsible for specific areas Pager calls can be alerted by beep only with a variety of sounds vibrate only or beep and vibrate together A text message on the clear backlit LCD display identifies the call type an...

Page 3: ...plete Pager must be returned to the manufacturer for battery replacement Do not expose to direct sunlight Do not fully submerge in water for prolonged periods Do not drop or expose to high vibration or shock Clean with a hard surface disinfectant wipe or a damp cloth and a non abrasive cleaning product Polish with a dry duster Avoid using harsh abrasive or corrosive cleaning agents or detergents e...

Page 4: ...your supplier or drop off at your local municipal waste recycling depot NTE E 4 MAINTENANCE CARE For peace of mind and to ensure your system is maintained to the highest standard Aidcall recommend an annual maintenance contract This will provide vital assistance in times of need from a nationwide team of trained Service Engineers who specialise in wireless Nursecall and Paging systems A preventati...

Page 5: ...ed period they can be turned off To turn OFF press and hold the Power Delete and Tick buttons together then release The Pager will beep and the display will go blank CONTENTS Power Button Message Scroll Button Press hold for manual volume vibrate settings and other options config Nurse Present Button Send IR Alarm Button 2 Line x 16 Character Backlit LCD Display Internal Beeper and Vibrate Alert D...

Page 6: ...on the second line To review the stored messages in rotation repeatedly press the Scroll button EME038 Daisy Ward Bedroom 038 The example EME038 shows an Emergency Call from unit ID 038 which is in Daisy Ward Bedroom 38 Other possible call types are listed below Code Call Type CAL038 Call from unit ID 038 NUR038 Nurse Present at unit ID 038 ASS038 Assistance Call from unit ID 038 EME038 Emergency ...

Page 7: ...ss the Delete button EME038 Daisy Ward DELETE After the first press of the Delete button the display will prompt DELETE If you re sure you want to delete ALL messages press Delete again ID101 L00R DELETED The Pager will momentarily display DELETED then return to the standby screen ...

Page 8: ... on the Nursecall panel NURSECALL PANEL DISPLAY The Nursecall panel will display the call like this The screen banner is green for a Nurse Present notification The Carer Name will be displayed or 2 digit Pager ID if unassigned Touch the banner to display Client Notes or press the Accept button to notify all other panels the call is being dealt with The banner changes to purple when a call is accep...

Page 9: ... button to cancel the call if the incident has been resolved or if the red button was pressed by accident After the first press of the button the display will prompt CANCEL If you re sure you want to cancel this call press the button again EMERGENCY RED BUTT 101 When the red Alarm button is pressed a call will go to all Pagers with the red button group code These Pagers will display EMERGENCY the ...

Page 10: ...ting the volume the display will show the current vibrate setting Press the Scroll button again to toggle between VIBRATE ON and VIBRATE OFF Press the button to select the chosen vibrate setting Note the vibrate setting can be changed but it will revert back to the default setting again when the Pager is placed in the Charging Rack After setting the vibrate the display will show the Software title...

Page 11: ... Pagers being inadvertently taken off site The Pager can only be reset by returning it to the Charging Rack 13 OPTIONAL EXIT ALARM The Bluebell system can be fitted with Exit Beacons in the vicinity of all exit doors These will automatically detect when a Pager is near to an exit door and sound an alert to remind the person not to leave the building with the Pager ID304 L00R PLACE IN RACK If a Pag...

Page 12: ...en the Staff ID will be 04 Note the last 2 digits must be 01 to 99 00 is not used The Pager ID can be changed by holding it alongside the Mini Logon Terminal as shown below Press the Power button and the Pager will display LOG ON Using the keypad on the Logon Terminal enter your new 3 digit ID it will show on the display as below When the correct digits are displayed on the Pager press the button ...

Page 13: ...terface to allow staff using the buildings internal telephone system to call Pagers and leave a telephone number they want the recipient to call back OPERATION dial the extension number for the Bluebell Telephone Interface it will answer with a welcome message and ask you to dial your information now followed by the key The dialled information is in the form of the 3 digit ID of the Pager or Pager...

Page 14: ...harge When placed in the charger the Pager will display CHARGING The heartbeat LED will be FLASHING RED when the Pager is charging When charging is complete the heartbeat LED will be STEADY RED and the display will show CHARGED This means the Pager should last for about 72 hours in normal use Partial top up charging is OK to give the Pager a quick charge if there is insufficient time to wait for t...

Page 15: ...ic ID s 000 FFF Programming Windows Utility Over air Battery Type Lithium Ion 3 7V 650mAh Typical Battery Life 72 hours based on 5 calls hour with beep vibrate Recharge Time 7 hours Typical Battery Replacement 2 5 years Wearing Options Belt Clip and Bungee Cord Enclosure Material Nylon PA12 Colour Blue Ingress Protection Rating IP67 Dimensions 82mm x 65mm x 16mm WxHxD Weight 105 grams including Ba...