6
Using RS422 requires the specific connection labeled
above. In order to chain more cameras, please go
out of the first camera with the following wiring and
into the next with the guide above. Once complete,
please select protocol VISCA, and address and
baudrate to set the camera.
Tip:
Don’t forget to set the ID address for each camera.
SECTION: 2
RS422 Connection:
Ra < --------- > TXD IN
-
Rb < --------- > TXD IN+
Ta < --------- > RXD IN
-
Tb < --------- > RXD IN+
Joystick
Camera#1 Camera#2
TXD OUT+ < --------- > RXD IN+
TXD OUT- < --------- > RXD IN-
RXD OUT+ < --------- > TXD IN+
RXD OUT- < --------- > TXD IN-
< --------- >
Summary of Contents for CCU-IP
Page 9: ...9 SECTION 3...