NAILER’S MAINTENANCE 

 

DISCONNECT 

THE 

NAILER 

FROM 

THE 

PNEUMATIC 

NETWORK. 

 

Removal of stuck nails. 

 

The nail is stuck in the shooting area. 

 
If  needed,  loosen  the  end  plate’s  screws  and  remove  the  protective  plate. 
Remove the stuck nail with pliers. 
 

The nail is stuck inside the chamber. 

 
Place  the  nail  feeder  to  the  backside  position  so  that  it  locks.  Remove  the 
stuck nails from the chamber. 
 

Check and replace any part of  the machine that is worn and damaged. 

 

LUBRICATION 

 
Disconnect the machine from the pneumatic network before lubrication. 
 
The nailer should be lubricated before using for the first time. 
 
Turn  the  nailer  upside  down  and  place  a  drop  of  lubricating  oil  into  the 
nailer through the pneumatic connector. Use the machine immediately after 
lubrication. 
 
Excess  oil  will  damage  the  O-ring  washers  and  cause  operational 
malfunctions. 
A daily lubrication is enough in continuous operations. 
 

CLEANING 

 
Never  use  gasoline  or  other  inflammable  liquids  to  clean  the  tool.  The 
steam inside the machine can cause an explosion. 
 
Remove  any  dirt  accumulated  outside  the  nailer  using  the  pneumatic 
compressor, clean and lubricate the safety mechanism  with compressor tool 
oil  whenever  necessary.  Do  not  use  lubrication  oil  in  excess.  Check  the 
safety protection function before using the device. 
 
The  nailer,  connectors  and  tubes  should  be  protected  against  dirt.  Coarse 
dust,  sand,  etc.  can  cause  malfunctions,  leaks  and  damage  both  nailer  and 
connectors. 

 
 

Summary of Contents for DAC1501

Page 1: ...BRAD NAILER DAC1501 Lue ja perehdy t h n ohjeeseen ennen koneen k ytt nottoa L s och s tt dig in i denna bruksanvisning innan du b rjar anv nda maskinen Read these instructions carefully before using...

Page 2: ...maliitin 1 4 NPT Maksimi sallittu paine 8 3 bar Suositeltava k ytt painealue 4 7 bar Ilman kulutus min 25kpl 53 20 l min Naula 1 25x1 00mm Naulan pituus 15 50 mm Kapasiteetti 100 kpl T rin 2 5 m s2 Me...

Page 3: ...k ytt tarkoitusta l Koskaan k yt naulainta palo tai r j hdysvaarallisessa tilassa l k yt happea tai r j ht vi kaasuja naulaimen k ytt voimana Varmista ettei liipaisin ole painettuna kun kytket naulai...

Page 4: ...inp in ja naulank rjet vastaavat lippaan pohjaan Ty nn lipas kiinni niin ett se lukkiutuu Kytke naulain kompressoriin k ytt en paineilmaletkua Varmista ett letku kest ty paineen ja ett siin on oikean...

Page 5: ...ja laita naulaimeen tippa ljy paineilmaliittimen kautta K yt konetta heti ljy misen j lkeen Liika ljy vahingoittaa O rengas tiivisteit ja aiheuttaa toimintah iri it P ivitt inen ljy minen on tarpeen...

Page 6: ...ista Tuote on palautettava t ydellisen varustettuna selostuksella toimintah iri ist Takuu raukeaa mik li kone on avattu osia vaihdettu sit korjattu tai sen rakennetta muutettu Takuu ei ole voimassa am...

Page 7: ...ryckluftsanslutning 1 4 NPT Arbetstryck max 8 3 bar Rekommenderat arbetstryck 4 7 bar Luftf rbrukning 53 20 l min Spik 1 25x1 00mm Spikets l ngd 15 50 mm Kapacitet 100 st Vibration 2 5 m s2 Bullerv rd...

Page 8: ...v nd aldrig utrustningen i brand eller explosionsfarliga utrymmen Anv nd aldrig syre eller explosiva gaser som drivkraft f r maskinen H ll inte startknappen intryckt n r du kopplar maskinen till tryck...

Page 9: ...plats i magasinet f rs kra dig om att spikarnas uddar r mot magasinets botten St ng magasinet s att det l ses Koppla spikpistolen till kompressorn med hj lp av tryckluftsslangen F rs kra dig om att sl...

Page 10: ...oppe olja i spikpistolen via tryckluftskopplingen Anv nd maskinen omedelbart efter sm rjning verfl dig olja skadar O ringen och orsakar funktionsst rningar Pistolen b r oljas dagligen vid kontinuerlig...

Page 11: ...helhet med en beskrivning av funktionsst rningarna Garantin g ller inte om maskinen har ppnats delar bytts ut om maskinen har lagats eller dess konstruktion ndrats Garantin g ller inte vid yrkesm ssi...

Page 12: ...air connector 1 4 NPT Maximum pressure 8 3 bar Recommended pressure zone for operation 4 7 bar Air Usage 53 20 l min Nail 1 25x1 00mm Nail Length 15 50 mm Capacity 100 pcs Vibration 2 5 m s2 Noise val...

Page 13: ...r if there is risk of explosion Do not use oxygen or explosive gases for the nailer s propulsion Make sure that no trigger is pressed when the nailer is connected to the pneumatic network Do not leave...

Page 14: ...o the right and nail points coincide with the bottom of the chamber Push the chamber back into place until it is locked Connect the nailer to the compressor using the pneumatic tube Make sure that the...

Page 15: ...r upside down and place a drop of lubricating oil into the nailer through the pneumatic connector Use the machine immediately after lubrication Excess oil will damage the O ring washers and cause oper...

Page 16: ...payment receipt purchase invoice warranty certificate or dispatching list The product should be wholly returned with an account of its malfunctions The warranty will be void if the machine has been o...

Page 17: ...DAC1501 17...

Reviews: