27
J4024-02 User Manual
Chapter 3. Sub-system Configuration Setup
3.5.2 How to configure T10 zoning
After enabling T10 zoning, five predefined groups are Group1, Group8, Group9,
Group10, and Group11.
Each PHY should be in one of the five groups, and all PHYs in a wide port should be in
the same group. Each PHY in Group1 can access any PHY in other groups, and vice
versa. Each PHY in Group8 cannot access any PHY in Group9, and vice versa.
The command syntax is "phyzone phy_index group". The following example shows
how to setup one drive accessed only by the first port and another drive accessed only
by the second port.
The configuration for the example is
(A) PHY0 - PHY3 for the first wide port
(B) PHY4 - PHY7 for the second wide port
(C) PHY12 - PHY35 for drive
Step 1
: Read the current group for PHY4
cmd> phyzone 4
Phy 4 for Zone Group 1
Step 2
: Assign the second port (PHY4 - PHY7) for Group9
cmd> phyzone 4 9
cmd> phyzone 5 9
cmd> phyzone 6 9
cmd> phyzone 7 9
Step 3
: Assign the first port (PHY0 - PHY3) for Group8
cmd> phyzone 0 8
cmd> phyzone 1 8
cmd> phyzone 2 8
cmd> phyzone 3 8
Step 4
: Assign the drive on PHY12 to be accessed only by the first port instead of the
second port
cmd> phyzone 12 8
Step 5
: Assign the drive on PHY13 to be accessed only by the second port instead of
the first port
cmd> phyzone 13 9
Step 6
: Reset for taking effect with the new settings
cmd> reset
Summary of Contents for J4024-02
Page 1: ...UM_J4024 02_v8 1_121619 J4024 02 12Gb s SAS JBOD Series User s Manual ...
Page 14: ...Chapter 1 Product Features J4024 02 User Manual 5 Rear Panel ...
Page 37: ...28 Chapter 3 Sub system Configuration Setup J4024 02 User Manual ...
Page 43: ...34 Chapter 3 Sub system Configuration Setup J4024 02 User Manual ...
Page 48: ...39 J4024 02 User Manual Chapter 3 Sub system Configuration Setup ...