2�4�1 Removing the hard disk tray

 Press the release button on the HDD tray lever to open the tray lever.

 Pull lever to dislodge the tray from the system.

2�4�2 Installing the hard disk tray

 Insert the HDD tray completely into the system with the tray lever open.

 Close the tray lever to secure the HDD tray.

 

2�4 Hard Disk Drive

Summary of Contents for FB122-PV

Page 1: ...UM_FB122 PV_v 3 3_061419 FB122 PV Storage Server Barebone User s Manual...

Page 2: ...DIMM Installation 15 2 4 Removing and Installing the Top Cover 16 2 4 1 Removing and installing the rear top cover 16 2 4 2 Removing and installing middle section of the top cover 16 2 5 Removing and...

Page 3: ...cement 40 3 7 2 Internal Connectors Jumpers 41 3 7 3 LED 42 3 7 4 Jumpers 43 Chapter 4 BIOS Configuration Settings 44 4 1 Navigation Keys 44 4 2 BIOS Setup 45 4 2 1 Menu 45 4 2 2 Startup 45 4 3 Main 4...

Page 4: ...etup 63 5 2 Method 2 Use a Dos Tool Syscheck 66 5 3 Login 68 5 4 Web GUI 69 5 4 1 Menu Bar 69 5 4 2 User Information and Quick Button 70 5 4 3 Dashboard 71 5 4 4 Sensor 71 5 4 5 FRU Information 71 5 4...

Page 5: ...Copyright 2018 AIC Inc All Rights Reserved This document contains proprietary information about AIC products and is not to be disclosed or used except in accordance with applicable agreements...

Page 6: ...istory Release Date Version Update Content 2018 1 Manual release to public July 2018 3 Content update Febuary 2019 3 1 1 New cover 2 Motherboard BIOS BMC update June 2019 3 3 1 Safety label 2 Image up...

Page 7: ...onsible for compliance could void your authority to operate the equipment Disclaimer AIC shall not be liable for technical or editorial errors or omissions contained herein The information provided is...

Page 8: ...a stable surface when install A drop or fall could cause injury Please keep this equipment away from humidity Carefully mount the equipment into the rack in such manner that it won t be hazardous due...

Page 9: ...he equipment has obvious signs of breakage 7 Please disconnect this equipment from the AC outlet before cleaning Do not use liquid or detergent for cleaning The use of a moisture sheet or cloth is rec...

Page 10: ...tings This chapter provides descriptions for the hardware including multifarious connectors jumpers and LED descriptions These descriptions assist users to configure different settings and functions o...

Page 11: ...damaged If any damage is found do not remove the components contact the dealer where the subsystem was purchased for further instructions Before continuing first unpack the subsystem and verify that...

Page 12: ...iSCSI TPM PICe Hotplug On board Devices SATA Intel Lewisburg PCH on chip solution 4 x SATA 6 0 Gb s by 1 x mini SAS HD 2 x SATA 6 0 Gb s by 2 x SATA 7 pin 5 x SATA 6 0 Gb s by Max I O BMC Aspeed AST25...

Page 13: ...on to the noteworthy features of the barebone FB122 PV provides immediate and efficient management with Onboard Baseboard Management Controller and greater I O extension Featuring IPMI 2 0 and Aspeed...

Page 14: ...l ICON System Behavior System Power Button Power switch System ID System ID on or off System Reset Reset the system LED indicator LED ICON Color System Behavior Power Green Solid System on Off System...

Page 15: ...LAN port Two10G SFP port 3 LAN port Two GbE RJ45 port 4 VGA port External DB 15 VGA port 5 PCIe 3 0 slot One OCP Mezzaine card V2 0 6 USB port Two USB 3 0 Type A 7 Serial port One Audio jack for COM p...

Page 16: ...6 Chapter 1 Product Features FB122 PV User Manual Major Components 750W 1 1 redundant power supply 80 Platinum AIC Server Board Pavo 6 x 40x56mm easy swap fan modules 10 x 2 5 hot swap drive bays...

Page 17: ...ver board includes two processor sockets LGA3647 that provides one or two processors of the Intel Xeon Processor Scalable Family and supports a Thermal Design Power TDP of up to 165W on selected model...

Page 18: ...designed to secure the Processor Heat Sink Module PHM to the server board as shown below CAUTION Previous generations of the Intel Xeon Processors and heat sinks are not compatible with the Intel Ser...

Page 19: ...he sub assembly where the heat sink and processor are clipped together onto the server board prior to installation The PHM consists of the components shown below Processor Heat Sink Module PHM Sub Ass...

Page 20: ...assembly the four heat sink torque screws must be tightened in order as shown below Processor Heat Sink Top View with Screw Tightening Order CAUTION Failure to tighten the heat sink screws in the spec...

Page 21: ...the screws on the heat sink with the screw holes on the motherboard CAUTION Avoid moving the heat sink after it has contacted the top of the CPU Too much movement could disturb the layer of thermal co...

Page 22: ...M Load Reduced DIMM LRDIMM NOTE In Pavo case the 16 lanes from CPU 0 and the 8 lanes from CPU 1 are routed to PCIe slots 1 The lanes from CPU 1 are routed to PCIe slots 3 and 4 CPU0 CPU0 CPU1 CPU1 DIM...

Page 23: ...CPU1 JDIMMD2 JDIMMK2 JDIMML JDIMMM JDIMMK1 JDIMMD1 JDIMME JDIMMF JDIMMC JDIMMB JDIMMA1 JDIMMA2 JDIMMJ JDIMMH JDIMMG1 JDIMMG2 6 DIMMs CPU0 CPU1 JDIMM_C JDIMM_J JDIMM_A1 JDIMM_G1 JDIMM_F JDIMM_M CPU0 C...

Page 24: ...JDIMML JDIMMM JDIMMK1 JDIMMD1 JDIMME JDIMMF JDIMMC JDIMMB JDIMMA1 JDIMMA2 JDIMMJ JDIMMH JDIMMG1 JDIMMG2 JDIMM_C JDIMM_B JDIMM_A1 JDIMM_D1 JDIMM_E JDIMM_F JDIMM_J JDIMM_H JDIMM_G1 JDIMM_K1 JDIMM_L JDIM...

Page 25: ...sional technicians only 2 2 2 DIMM Installation Step 1 Unlock the dimm socket by pressing the retaining clips outward Step 2 Insert the memory module into the slot Make sure that the DIMM notch is acc...

Page 26: ...ar top cover Push the cover toward the rear panel and lift upward to remove 2 3 2 Removing and installing middle section of the top cover Loosen the screws on the middle section of the top cover x 6pc...

Page 27: ...Removing the hard disk tray Press the release button on the HDD tray lever to open the tray lever Pull lever to dislodge the tray from the system 2 4 2 Installing the hard disk tray Insert the HDD tra...

Page 28: ...g the hard disk drive Place one HDD SSD on the tray and then secure it with four screws on the HDD tray The mounting screw holes may vary according to different types of HDDs SATA SAS Drive PCIe Drive...

Page 29: ...ow the direction to remove the fan housing from the base Pull the fan housing upward NOTE 1 Push and the fan housing down onto the base 2 Make sure the fan housing is bucked up on the base as shown ma...

Page 30: ...tup FB122 PV User Manual 2 5 2 Installing the fan Follow the direction and insert the ping into fan bar as shown Prepare to place the fan housing down and onto the base Push down the fan housing and a...

Page 31: ...TE The fan should be blowing toward the rear end of the chassis If one of the fans is facing the wrong direction please remove reinstall the fan so that it is facing the correct direction This informa...

Page 32: ...card Unfasten the two screws that secure the bracket to the chassis Unfasten the two screws that secure the card retainer to the chassis Card Retainer Card Retainer 2 7 Replacing the PCIe Card and Ri...

Page 33: ...Setup FB122 PV User Manual Disconnect the card from the Riser Card Assembly Slide the PCIe Card rightward and then upward to remove the card out of the chassis This information is provided for profess...

Page 34: ...ide that came with your purchased product This information is provided for professional technicians only Pull the inner rail out of the slide rail until it clicks Detach the inner rail completely from...

Page 35: ...secure the screws on sides of the system Continue installing the outer rail bracket to the mounting frame Attach the outer rail assembling to the frame and press the bracket to form a rack on both en...

Page 36: ...ut the middle channel until the ball bearing retainer is locked forward CAUTION Verify if the ball bearing retainer is locked forward 7 Slide the release tab and push barebone into rack Make sure the...

Page 37: ...27 Chapter 3 Hardware Settings FB122 PV User Manual This section describes the jumpers internal connectors and internal LED settings 3 1 Motherboard Block Diagram Chapter 3 Hardware Settings...

Page 38: ...PCH SSGPIO Header J27 9 Front USB 3 0 Port J16 31 BMC Disable J30 10 Front USB 2 0 Port J49 32 Password Clear J31 11 DIMM Slots J56 J58 J61 J65 J69 J76 33 PECI J44 12 CPU Sockets U55 U78 34 VRM SMB H...

Page 39: ...tings FB122 PV User Manual 3 3 Motherboard Layout 37 a 3 b 3 a 27 9 18 13 6 8 7 14 28 25 29 30 16 10 44 43 36 5 1 24 26 2 34 9 15 31 32 21 35 42 41 22 40 39 23 38 b 20 4 17 19 a 38 a 11 16 DIMM Socket...

Page 40: ...D VGA_5V AHSYNCO DACBO GND NC DACRO 1 2 15 16 10 2 9 1 DSR RTS CTS RI NC DCD RXD TXD DTR GND 3 4 Internal Connectors Jumpers 13 6 8 7 GND KEY P5V PCH_IO2 PCH_IO1 GND SMB_PCH_SDA ESPI_CS1 PCH_CLKRUN ES...

Page 41: ...AD SGPIO_SATA0_CLOCK 1 3 GND RXD TXD I2C1SDA GND I2C1SCL NC 5 1 1 23 2 24 GND FAN_PWM5 FAN_PWM4 FAN_PWM3 FAN_TACH11 FAN_TACH10 FAN_TACH9 FAN_TACH8 FAN_TACH7 FAN_TACH6 I2CSCL GND GND FAN_PWM2 FAN_PWM1...

Page 42: ...rt J16 18 Intruder Header J47 37 BMC Fan Header J51 11 20 10 1 VDD_USB_P34 USB3_RX_N2 USB3_RX_P2 GND USB3_TX_N2 USB3_TX_P2 GND USB2_N2 USB2_P2 PCH_USB_OC 2 KEY VDD_USB_P34 USB3_RX_N3 USB3_RX_P3 GND US...

Page 43: ..._BTN GND PWR_BTN HD_LED HD_LED PWR_LED KEY PWR_LED LAN2_ACT LAN2_ACT INTRUDER_N I2CCLK I2CSDA LAN1_ACT LAN1_ACT FAULT_LED FAULT_LED UID_LED UID_LED 3 3V_DUAL 1 2 23 24 CHASSIS_1U2N_N BNC_GPIO_EXI N FA...

Page 44: ...M 41 BMC Reset J23 J23 Setting Short BMC Reset Open Normal Default 21 Speaker Header J48 31 BMC Disable J30 J30 Setting Short BMC Disable Open Normal Default 39 BIOS Recovery Mode J37 J37 Setting Shor...

Page 45: ...linking Disk activity is detected Off No disk activity is detected LAN1_TRAFFIC Green Blinking LAN1 activity is detected Off LAN1 is not active LAN2_TRAFFIC Green Blinking LAN2 activity is detected Of...

Page 46: ...CH LAN LEDs LED5 Green LAN1 activity is detected Off LAN1 is not active LED7 Green LAN1 link is detected Off LAN1 is not linked LED6 Green LAN0 activity is detected Off LAN0 is not linked LED4 Green L...

Page 47: ...37 Chapter 3 Hardware Settings FB122 PV User Manual 3 6 1 Placement PCBA Placement Connector Location J1 J4 J2 J3 GF1 PCIe 1 CN1 CN2 CN5 CN6 CN7 CN8 CN9 CN10 CN11 CN12 J3 GF2 GF3 3 6 HDD Backplane...

Page 48: ...EN_N10 PWREN_N11 GND GND GND PWREN_N0 PWREN_N1 PWREN_N4 PWREN_N5 PWREN_N6 PWREN_N7 PWREN_N8 PWREN_N9 PWREN_N10 PWREN_N11 GND GND GND J4 NC GND TX_DP0 TX_DN0 GND TX_DP1 TX_DN1 GND SMB_CLOCK SMB_DATA GN...

Page 49: ...39 Chapter 3 Hardware Settings FB122 PV User Manual 3 6 3 LEDs LED Definition Repeater LED LED7 Yellow On EEPROM load passed Off EEPROM load incomplete LED7 LED7...

Page 50: ...40 Chapter 3 Hardware Settings FB122 PV User Manual 3 7 1 Placement PCBA Placement Connector Location 3 7 Riser Card...

Page 51: ...B122 PV User Manual 3 7 2 Internal Connectors Jumpers J2008 J2008 J2005 J2004 J2007 J2006 J2001 J2003 J2002 J2002 J2004 12V GND GND 5V A J2003 GND E_ACT_IN0 E_ACT_IN1 FAIL0 FAIL1 J2002 12V GND GND 5V...

Page 52: ...VMe SSD present Blue Blinking NVMe SSD Activity detected or Locate NVMe SSD Off NVMe SSD no connect or No Access HDD Fault Status LEDs D11 D13 Off Normal Orange On NVMe SSD 12V Power OFF Repeater EEPR...

Page 53: ...FB122 PV User Manual 3 7 4 Jumpers Jumper Definition Jumper for NVMe I2C_Bus J2005 Open Through CPU_I2C Close Through BMC_I2C Jumper for Active LED J2004 Open P11 DAS active high SAS Close P11 DAS act...

Page 54: ...tem off and on NOTE The following pages provide the details of BIOS menu Please be noticed that the BIOS menu are continually changing due to the BIOS updating The BIOS menu provided are the most upda...

Page 55: ...sic system information and date time Advanced Allows configuration of advanced system settings Security Sets passwords and security functions Power Sets the power management parameters Boot Sets boot...

Page 56: ...ation Settings FB122 PV User Manual There will be a message Entering SETUP displayed on the diagnostics screen Identify the BIOS version NOTE For the official released version the last digit of the BI...

Page 57: ...47 Chapter 4 BIOS Configuration Settings FB122 PV User Manual Load Optimal Default Setting Save the setting and exit the BIOS setup utility...

Page 58: ...48 Chapter 4 BIOS Configuration Settings FB122 PV User Manual Main Option Key 4 3 1 Main Option Key Description System time Configures the current time System date Configures the current date 4 3 Main...

Page 59: ...PCIe ARI Enable Disable ARI Forward Enable Disable Spread Spectrum Enable Disable Redfish On Off Enable Disable 4 4 2 Video Configuration Video Configuration Display Mode Plug In First On Board First...

Page 60: ...ncy Select 9 6Gb s 10 4Gb s Auto Use Per Link Setting Link L0p Enable Auto Enable Disable Link L1 Enable Auto Enable Disable Legacy VGA Socket Min 0 Max 3 Legacy VGA Stack Min 0 Max 6 Memory Configura...

Page 61: ...able PCIe ACPI Hot Plug Enable Disable Per Port MC BaseAddress Range Auto Below 4G MC Index Position 12 20 MC Num Group 1 8 32 64 PCI E Completion Timeout Global Disable No Yes Per Port PCI E Global T...

Page 62: ...are PM State Control Hardware P States Disable Native Mode Out of Band Mode Native Mode with No Legacy Support HardwarePM Interrupt Enable Disable EPP Enable Enable Disable EPP profile Performance Bal...

Page 63: ...t Plug Enable Disable Configure as eSATA Enable Disable Mechanical Presence Switch Enable Disable Spin Up Device Enable Disable SATA Device Type Hard Disk Drive Sata State Drive SATA Topology Unknown...

Page 64: ...eSATA Enable Disable Spin Up Device Enable Disable sSATA Device Type Hard Disk Drive Sata State Drive SATA Topology Unknown ISATA Direct Connect Flex M 2 Port 1 Enable Disable Hot Plug Enable Disable...

Page 65: ...ec 1s 3 5s Disable MPL for Uplink x16 MPL for Uplink x8 MPL 128B MPL 256B MPL 512B PCIE Clock Gating Enable Disable PCH DMI ASPM Platform POR ASPM L Disable DMI Link Extended Synch Control Enable Disa...

Page 66: ...Error Reporting Enable Disable PCIe Speed Auto Gen 1 Gen 2 Gen 3 MSI Enable Disable PCIE Lane Topology Unknown x1 x4 Sata Express M 2 Max Payload Size MPL MPL 128B MPL 256B Compl Timeout 40 50ms spec...

Page 67: ...Max 240 ACPI SPMI Table Enable Disable Boot Option Support Enable Disable Set BIOS version to BMC Enable Disable BMC Configuration Watchdog Timer Support Enable Disable Not disable in OS Enable Disabl...

Page 68: ...Rate 1200 2400 4800 9600 19200 38400 57600 115200 Data Bits 7 Bits 8 Bits Parity None Even Odd Stop Bits 1 Bits 2 Bits Flow Control None RTS CTS XON XOFF Information Wait Time 0 Second 2 Seconds 5 Se...

Page 69: ...User Manual Security Option Key 4 5 1 Security Security Current TPM Device Not Detected TPM 1 2 TPM 2 0 TrEE Protocol Version 1 0 1 1 TPM Availability Available Hidden TPM Operation No operation Disab...

Page 70: ...60 Chapter 4 BIOS Configuration Settings FB122 PV User Manual Power Option Key 4 6 1 Power Power Wake on PME Enable Disable 4 6 Power...

Page 71: ...Quiet Boot Enable Disable Network Stack Enable Disable PXE Boot to LAN Enable Disable PXE Boot capability Disable UEFI IPv4 UEFI IPv6 UEFI IPv4 UEFI IPv6 Legacy Add Boot Options First Last Auto ACPI S...

Page 72: ...your changes without exiting the system Exit Discarding Changes Discard your changes when existing the system Load Optimal Defaults Load optimal default items Load Custom Defaults Resets the BIOS sett...

Page 73: ...onfiguration Settings Insert Ethernet LAN cable into the BMC LAN port There are two methods to setup BMC IP 5 1 Method 1 Use the BIOS Setup BIOS SETUP Advanced H2O IPMI configuration BMC Configuration...

Page 74: ...64 Chapter 5 BMC Configuration Settings FB122 PV User Manual Type in the IP address Configure the static IP adress...

Page 75: ...65 Chapter 5 BMC Configuration Settings FB122 PV User Manual Type in the subnet mask address Type in the gateway address...

Page 76: ...onfiguration Settings FB122 PV User Manual 5 2 Method 2 Use a Dos Tool Syscheck Type in sc lanset Modify the IP setting NOTE Type 1 for selecting Static IP Mode or type 2 for selecting DHCP Mode Type...

Page 77: ...Manual Type in the submask address The IP address below is an example using a default IP setting The IP address is configurable Configure the gateway address to complete the BMC IP setting NOTE Type S...

Page 78: ...r Static by the BIOS utility or the system check Open the browser then type the BMC IP address Use the default user name and password for first time BMC WEB GUI login Field Default UserName admin Pass...

Page 79: ...and Reports page monitors and reports on the status of IPMI event and video Settings The Settings page allows you to configure various basic settings such as date time KMV Mouse Services and ect Remo...

Page 80: ...mands are allowed except for the configuration commands that can change the behavior of the out of hand interfaces Administrator All BMC commands are allowed No access Login access denied Notification...

Page 81: ...status of adevice 5 4 4 Sensor The Sensor Readings page displays all the sensor related information 5 4 5 FRU Information The FRU Information page displays Basic Information Chassis Information Board...

Page 82: ...ngs FB122 PV User Manual 5 4 6 Logs and Report The System Inventory page displays IPMI Event Log and Video Log Click Logs and Reports from the menu bar 5 4 7 Settings The Settings page allows you to a...

Page 83: ...ows you to configure the mouse mode to relative absolute and other For Windows OS environment set mode to absolute For Linux OS environment set mode to relative For SLES 11 OS environment set mode to...

Page 84: ...74 Chapter 5 BMC Configuration Settings FB122 PV User Manual Launch KVM...

Page 85: ...rt ru aicipc com tw North California United States Address 48531 Warm Springs Boulvard Suite 404 Fremont CA 94539 United States Tel 1 510 573 6730 Fax 1 510 573 6729 Sales Email sales aicipc com Suppo...

Reviews: