2. Controls 

 

1. Envelope Out

The brightness of this LED 

indicates the level of the output. 
 

2. Loop / Envelope Toggle

This toggle selects the 

two modes of the Looping Envelope Generator, 
Loop or Envelope.  
 

3. Manual Trigger.

 

In Envelope mode, this button 

will manually activate an AD Trigger when either of 
the following are true: 1) There is no cable in the 
Gate input, or 2) There is a cable in the gate input, 
and a gate signal is present. 
 

4. Trigger Input.

 

In Envelope mode, when the 

trigger input voltage is high (from a clock, keyboard, 
or lfo for example) an AD Trigger will activate when 
either of the following are true: 1) There is no cable 
in the Gate input, or 2) There is a cable in the gate 
input, and a gate signal is present. 
 

5. Gate Input.

 

In Envelope mode, when the gate 

input voltage is high (from a clock, keyboard, or lfo 
for example) an ADSR Envelope will activate. 
 

6. Attack. 

In Envelope and Loop mode, the position 

of this knob sets the Attack time, or the time it takes 
for the Output to go from 0 voltage at the start of an 
ADSR envelope, AD Trigger, or AD loop, to 

maximum voltage. Times range from 20ms to 14 seconds.  
 

7. Decay. 

In Envelope and Loop mode, the position of this knob sets the Decay time, or the time it takes for 

the Output to go from maximum voltage after the Attack Phase to either 0 Voltage of an AD Trigger,  or to the 
Sustain Level of an ADSR Envelope or AD Trigger. Times range from 10ms to 20 seconds.  
 

8. Sustain. 

In Envelope mode, the position of this knob sets the level of the Output voltage while gate is true 

(a key is held). In AD Trigger mode, the position of this knob sets the return voltage, and the knob must be set 
to zero in order to “reset.” 
 

9. Release. 

In Envelope mode, the position of this knob sets the time it takes for the Output voltage to return 

to zero from the sustain level when gate is False. Times range from 100ms to 7 seconds. 
 

10. Out. 

This is the primary voltage output, with levels ranging from 0 to 7.5V.

 