en | AHT Cooling Systems GmbH
Maintenance, service, and repairs | 12
405859_1_0819
43 / 505
Switch off cooling
function (start de-
frosting manually)
Press
for at least 3 sec-
onds.
appears on the display.
–
Allow the appliance to defrost.
–
Remove the lid (see Setup and installation).
–
If required, take accessory parts out the inside
of the appliance (see
→ Setup and function).
–
Remove food residues (e.g. due to breakage of
packaging) and packaging residues. Remove
defrosting water.
–
Wet vacuum cleaner / electric appliance with
explosion protection mark
–
Lightly moistened, soft cotton cloth
–
Clean the defrosting drain.
–
Remove and clean the condensation water
sieve.
Fig. 9:
Defrost water sieve (1), defrosting drain (2)
–
Clean the surfaces inside.
–
Dry all cleaned parts and surfaces. Correctly
reinstall accessory parts removed.
–
Properly install the lid (see
→ Setup and instal-
lation) and close it completely.
–
Switch on the cooling function (see
→
page 11,
chapter 5
).
Switch on the cool-
ing function
Press
for at least 3 sec-
onds. The interior temperature
appears on the display.
–
Clean the floor around the appliance.
NOTICE
Property damage due to misuse.
▪
Only add goods to the appliance once the
specified temperature for the product has
been reached.
Check the temperature display and display indicator
page 11, chapter 5
.
12 Maintenance, service, and
repairs
Responsibility
Qualified staff
Only specialist personnel may carry out service and re-
pair work, including the following function tests.
The appliance does not need any regular maintenance.
In the event of questions relating to maintenance, contact
the maintenance service (see
→ Maintenance services).
WARNING
Work on the electrical system and re-
frigerant circuit.
Contact with live parts may result in electric
shock. Flammable refrigerant can escape and
cause an explosive gas/air mixture. Fire haz-
ard due to sparking or overload.
▪
Only qualified staff may carry out
work on the electrical system and re-
frigerant circuit.
▪
Note safety instructions, page 7, chap-
ter 2.5.
▪
Observe the electrical safety rules
prior to commencing work.
1. Disconnect the appliance.
2. Secure the appliance against reconnec-
tion.
▪
During the repair a competent per-
son with knowledge of local condi-
tions must be available as contact for
the qualified staff.
▪
Only qualified staff may restart the
appliance and perform functional
tests.
CAUTION
Sharp edges, rotating parts. Hot sur-
faces.
Risk of injury to hand and body. Risk of burns
in the event of skin contact.
▪
Only specialist personnel may carry
out service and repair work on the
appliance.
▪
Use protective gloves.
▪
Touch hot surfaces, in particular the
compressor, only after they have
cooled down.
12.1 Replacing lights
Responsibility
–
Qualified staff
If a light fails, contact the maintenance service (see
→
Maintenance services).
Lights used
–
LED bars
For technical data, see
→ Technical data
WARNING
Work on the electrical system.
Contact with live parts may result in electric
shock.
▪
Only qualified staff may replace
lights.
▪
Observe the electrical safety rules
prior to commencing work.
1. Disconnect the appliance.
2. Secure the appliance against reconnec-
tion.
Summary of Contents for MACAO 100
Page 24: ...AHT Cooling Systems GmbH 24 130 405859_1_0819 ...
Page 45: ...en AHT Cooling Systems GmbH Disposal 13 405859_1_0819 45 505 ...
Page 67: ...fr AHT Cooling Systems GmbH 405859_1_0819 67 505 ...
Page 89: ...it AHT Cooling Systems GmbH 405859_1_0819 89 505 ...
Page 111: ...pt AHT Cooling Systems GmbH Índice de conteúdos 405859_1_0819 111 505 ...
Page 133: ...es AHT Cooling Systems GmbH 405859_1_0819 133 505 ...
Page 156: ...AHT Cooling Systems GmbH de 156 505 405859_1_0819 ...
Page 177: ...et AHT Cooling Systems GmbH Utiliseerimine 13 405859_1_0819 177 505 ...
Page 199: ...fi AHT Cooling Systems GmbH 405859_1_0819 199 505 ...
Page 224: ...13 Απόρριψη AHT Cooling Systems GmbH el 224 505 405859_1_0819 ...
Page 246: ...AHT Cooling Systems GmbH de 246 505 405859_1_0819 ...
Page 268: ...AHT Cooling Systems GmbH lv 268 505 405859_1_0819 ...
Page 290: ...AHT Cooling Systems GmbH lt 290 505 405859_1_0819 ...
Page 312: ...13 Verwijdering AHT Cooling Systems GmbH nl 312 505 405859_1_0819 ...
Page 335: ...pl AHT Cooling Systems GmbH Utylizacja 13 405859_1_0819 335 505 ...
Page 358: ...13 Eliminare ca deşeu AHT Cooling Systems GmbH ro 358 505 405859_1_0819 ...
Page 378: ...13 Avfallshantering AHT Cooling Systems GmbH sv 378 505 405859_1_0819 ...
Page 399: ...sk AHT Cooling Systems GmbH Likvidácia 13 405859_1_0819 399 505 ...
Page 420: ...13 Odstranjevanje AHT Cooling Systems GmbH sl 420 505 405859_1_0819 ...
Page 441: ...cs AHT Cooling Systems GmbH Likvidace 13 405859_1_0819 441 505 ...
Page 463: ...hu AHT Cooling Systems GmbH Ártalmatlanítás 13 405859_1_0819 463 505 ...
Page 484: ...AHT Cooling Systems GmbH no 484 505 405859_1_0819 ...
Page 505: ...tr AHT Cooling Systems GmbH Tasfiye 13 405859_1_0819 505 505 ...