ASPIRATOR

NASAL

AGU NS15

EN

USER MANUAL

agu–baby.com

Summary of Contents for Daisy NS15

Page 1: ...ASPIRATOR NASAL AGU NS15 EN USER MANUAL agu baby com ...

Page 2: ... Product overview 7 5 Battery installation replacement 8 6 Instruction for use 9 7 Care and maintenance 11 8 Troubleshooting 14 9 Technical specification 14 10 Technical data 15 11 Storage transportation and operation rules 19 12 Disposal 19 13 Manufacturer s warranty 19 NASAL ASPIRATOR AGU NS15 EN ...

Page 3: ...ompact easy design This device is compact and easy to hold and operate Washable parts Tips and mucus cup are removable and easy to clean the mucus cup can be disinfected with boiling water Light weight low noise The child calmly responds to the procedure of cleansing the nose Battery This device uses two 1 5 V AA batteries it is convenient to replace the batteries anytime anywhere Please read this...

Page 4: ...ards Please read the instruction manual Device classification type BF Manufacturer Ingress protection rating Leading digit protection against ingress of solid foreign objects 2 protection against ingress of solid objects more than 12 mm in size fingers or other objects with a maximum length of 80 mm or solid objects Second digit protection against ingress of foreign liquids 2 protection against ve...

Page 5: ...riod of time 6 To start the operation of the device press and hold the on off button for some time If you need to stop suction just release the button and the device will turn off 7 The nasal aspirator is for cleaning removing the nasal secretion only Do not use this device other than the intended purposes 8 During the use of the device the babies should not hold their breath close their mouth or ...

Page 6: ... nasal bleeding acute head facial or neck injury coagulopathy or bleeding disorder 14 Before using the device please read this user s manual carefully Incorrect use of the device may cause the following hazards compli cations mechanical trauma nasal bleeding damage of mucous membrane of the nose 15 Please keep the replaceable tips out of the reach of children children and pets cannot access to avo...

Page 7: ...7 EN PRODUCT OVERWIEW L S Silicone Tip L Collar Button Main Body Silicone Ring Mucus cup Battery cover Silicone Tip S ...

Page 8: ...symbols Always use new batteries 4 Replace the battery cover NOTE Please do not expose the batteries to high temperatures and dispose them properly Keep them out of children s reach It is recommended to remove the batteries if the unit is not used for a long period of time Batteries and electronic devices should be disposed of in accordance with local recycling regulations and never dispose of the...

Page 9: ...completely covering the rib before using Check the tip before each use If you notice any signs of wear or damage change it immediately The Tips belong to consumables their service life depends on the frequency of use of the device We recommend replacing Tips every six months of use 3 Press and hold the Power button while the device is clearing the mucus Silicone Tip S S L Silicone Tip L ...

Page 10: ...p by removing the tip from the aspirator 5 Release power button to stop the suction ATTENTION The time of continuous opera tion of the device should not exceed 20 seconds ATTENTION In order to prevent getting liquid inside the main unit of thedeviceanditsfailure please do not exceed the maximum mucus volume in mucus cup In case of filling the mucus cup clean it for continued use after completion o...

Page 11: ... Make sure that both parts of the device main unit and battery cover are tightly seated together 2 With a gentle movement disconnect the mucus cup with the tip from the aspirator body 3 Remove the silicone gaskets 1 3 2 Click 4 5 ...

Page 12: ...e device in clean water as shown and press the button hold for no more than 15 seconds Perform this procedure several times change the water if necessary 2 Take the device out of the water Press and hold the power button until water stops flowing out of the outlet 3 Wait until the device dries completely for 1 3 hours Then collect it Click ...

Page 13: ...sh this device with any kinds of strong soap or cleaner Please just wash the mucus cup head module and tip with water and mild soap only DO NOT expose the main body of device to high temperatures more than 60 C The mucus cup and silicone tips can be disinfected with boiling water 120 sec max UNIT CLEANING It is strongly recommended to wipe the unit with a clean soft dry cloth and keep the device c...

Page 14: ...er is not inserted correctly Make sure that the muscus cupis connected with the body of the aspirator tight without gaps WARNING If the device does not work even after taking the above mentioned actions please contact the store where it was purchased or the nearest dealer Never turn the device on if any part of it is broken or does no longer work properly TECHNICAL SPECIFICATION Product Nasal aspi...

Page 15: ... the right to introduce changes into the device design TECHNICAL DATA Nasal aspirator AGU NS15 conforms to the provisions of the EC directive MDD 93 42 EEC GUIDANCE AND MANUFACTURER S DECLARATION ELECTROMAGNETIC EMISSIONS The Nasal aspirator AGU NS15 is intended for use in the electromagnetic environment specified below The customer or the user of the nasal aspirator AGU NS15 should assure that it...

Page 16: ...ded for use in the electromagnetic environment specified below The customer or the user of the nasal aspirator AGU NS15 should assure that it is used in such an environment Immunity test IEC 60601 test level Compliance level Electromagnetic environment guidance Electrostatic discharge ESD IEC 61000 4 2 6 kV contact 8 kV air 6 kV contact 8 kV air Floors should be wood concrete or ceramic tile If fl...

Page 17: ...rangeb Interference may occur in the vicinity of equipment marked with the following symbol NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations Electromagnetic propagation is affected by absorption and reflection from structures objects and people a Field strengths from fixed transmitters such as base stations for radio cellular c...

Page 18: ...ations equipment Rated maximum output power of transmit ter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 P 80 MHz to 800 MHz d 1 2 P 800 MHz to 2 5 GHz d 2 3 P 0 01 0 12 0 12 0 23 0 1 0 38 0 38 0 73 1 1 2 1 2 2 3 10 3 8 3 8 7 3 100 12 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in metres m ca...

Page 19: ...ed as household waste With the proper disposal of the product you will help to prevent possible negative effects of the device on the environment and human health The device should not be disposed of with domestic household waste for the environment protection The product should be disposed of in accordance with local regulations The device wshould be disposed of in accordance with the Directive E...

Page 20: ...onsumer of the rules of storage cleaning transportation and maintenance of the device stipulated by the operation manual penetration of oil dust insects liquids not intended for the use with devices and other foreign matters inside the device The warranty does not cover the defects faults of the device caused by the following reasons normal wear and tear of component parts with a limited service l...

Page 21: ...lesperson Signature of salesperson The set completeness and operation of the device are tested in the presence of the buyer Name of purchaser Signature of purchaser ATTENTION This warranty is valid only if the documents are filled in properly seal of retailer 24 months warranty ...

Page 22: ...AGU NS15 Applications to service and repair center Date Reason Recommendations Date Reason Recommendations Date Reason Recommendations ...

Page 23: ...cturer Asia Connection Co Ltd 16F 1 No 16 Jian Ba Road Chung Ho District New Taipei City 23511 Taiwan Republic of China Authorized representative in the EU Obelis s a Boulevard General Wahis 53 1030 Brussels Belgium 1639 ...

Page 24: ...AGU is the registered trademark by Montex Swiss AG Tramstrasse 16 CH 9442 Berneck Switzerland ...