![AGT INDUSTRIAL 13.5HP B&S Product Manual Download Page 42](http://html1.mh-extra.com/html/agt-industrial/13-5hp-bands/13-5hp-bands_product-manual_2870200042.webp)
42
SERVICE TECHNOLOGIES
https://www.agrotkindustrial.com
/
Others
Parts
Quantity
Interval
(
h)
10 50 100 250 500 1000 2000 4000
Check if the bucket teeth
is worn or loosened.
★
Change the bucket
If needed
Replace the bucket and connect
the new one to machine.
If needed, replace the bucket and connect
the new one to machine
Adjust the connecting rod of bucket
1
If needed
Take down the traveling lever
2
If needed
Check and replace the fuse
1
★
Every 3 years
Check the track defection
2
★
★
Maintenance of tensioner
2
◎
Check the fuel injection timing
◎
Measure the compression pressure of engine
Check the starter and the AC generator
Check the bolts and nuts for tightening torque
▢
★
Note:
★
normal maintenance interval
◎
Contact dealers
▢
Maintenance needed at the first inspection
Check the bucket teeth -each day
1. Check if the bucket teeth is worn or loosened.
Worn beyond the service limit, the bucket teeth may be replaced.
Bucket tooth dimensions mm
New
Service
190
130
Caution: care must be taken to avoid the metal scrap from flving out, leading to personal
injury. Wear the goggles or the safe glasses or safe devices suitable for operations!