3

GrowNET™ Hubs

All GrowNET™ devices are connected using standard CAT5 Ethernet cable with RJ-45 connections. 

Devices can be connected directly to the GrowNET™ ports on the bottom of the controller, or through HX8 

GrowNET™ hubs. It is typical to simplify cabling by locating hubs centrally in hall ways and rooms allowing 

single runs from an 8-port device hub back to a central hub or back to the controller. 

HX8 GrowNET ™ hubs expand a single port into eight more ports. 

Hubs can be daisy-chained to form a network of up to 100 devices per 

GrowNET™ bus. Individually buffered port transcievers provide excellent 

signal integrity and extended communication strength and range.

Hubs provide up to 1A of power for operating sensors and most relays 

directly over the CAT5 cable. A DC jack on the hub provides 24Vdc power 

to the ports from the included wall power supply. A terminal block 

power option is also available.

 DIELECTRIC GREASE

Dielectric grease is recommended on RJ-45 GrowNET™ connections when used in humid environments. 

Place a small amount of grease onto the RJ-45 plug contacts before inserting into the GrowNET™ port.

Non-conductive grease is designed to prevent corrosion from moisture in electrical connectors.

• Loctite LB 8423 

 

• Dupont Molykote 4/5 

 

• CRC 05105 Di-Electric Grease

• Super Lube 91016 Silicone Dielectric Grease 

• Other Silicone or Lithium based insulating grease

 NOTICE

GrowNET™ ports use standard RJ-45 connections but are NOT compatible the Ethernet network equipment. 

Do not connect GrowNET™ ports to Ethernet ports or network switch gear.

Installation Notes

Refer to the GCX controller manual for details on adding the device to the system.

Connection to GrowControl™ GCX

Summary of Contents for SXC

Page 1: ...CO2 Range 0 2000ppm 10 000ppm Modbus CO2 Accuracy 50ppm 3 of reading 4 20mA DAC Resolution 12 bit 0 005mA Interface GrowNET MODBUS or WiFi Specifications Climate Sensor Data Logger Contents Installati...

Page 2: ...Reset Wall mounting slots are provided for installing against a vertical wall surface or a hanging bracket is avail able for conveniently suspending the sensor from a wire or cable in the middle of t...

Page 3: ...g sensors and most relays directly over the CAT5 cable A DC jack on the hub provides 24Vdc power to the ports from the included wall power supply A terminal block power option is also available DIELEC...

Page 4: ...able terminal block for wire connections Terminal block includes 24V power terminals and four terminals for the analog channels 4 20mA linear outputs correspond to the ranges in the specifications tab...

Page 5: ...Alternate speeds and formats between 9 600 115 200 baud may be configured with the free AgrowLINK PC utility using a LX1 USB AgrowLINK and the cross over adapter supplied with the LX2 ModLINK MODBUS...

Page 6: ...ity x10 0 1000 0 100 3 Light x1 0 1000 W m2 4 CO2 x1 0 10 000 ppm Sensors with alternate units may toggle the units using the toggle units register To toggle the units send the sensor channel number t...

Page 7: ...008 HW Version Hardware Version ASCII 8 char R 40012 FW Version Firmware Version ASCII 8 char R 40016 Toggle Units Toggle sensor units 1 4 16 bit unsigned W 41002 Sensor Reading Integer Temperature 20...

Page 8: ...and lift off the cover 5 Locate the CO2 headers on the circuit board 6 Position and install the CO2 sensor module 3 ensuring the sensor is oriented with the correct pin head ers One header is 4 pins...

Page 9: ...er 2 1 3 The fan air filter should be periodically removed for cleaning It is NOT necessary to remove the fan 1 Pry the retaining grate 1 out of the base 3 using a small flat blade eye glass screwdriv...

Page 10: ...cretion of the Agrowtek Inc at no charge This warranty is provided in lieu of all other warranty provisions express or implied It is including but not limited to any implied warranty of fitness or mer...

Reviews: