background image

© Agrowtek Inc.   |  www.agrowtek.com  |  Technology to Help You Grow™

3

Do NOT connect the GrowNET port to Ethernet networks.

Replaceable

Pump Head

1/4” Tubing

Chemical Resistant

FDA Compliant, Food Safe

GrowNET™ Port

MODBUS RTU

Mounting Holes

24V DC Power Jack

IN

OUT

Mount the pump on a vertical wall surface using the holes in the mounting flanges. The center flange hole 

may be used to hang and level  the pump, however, the corner screw holes should be used for final mount-

ing. Use caution to avoid over-tighteneing the screws and bending the flanges.

A 120Vac wall receptacle is required within 6ft of the pump for the power adapter.

Installation Instructions

FROM

SAMPLE

PUMP

WATER

TANK

RETURN

PBX-104

Injection Manifold

Pressure Outlet

Suction Inlet

(optional)

Each pump has an inlet (suction) and outlet 

(pressure) tube. Using included barbed tubing 

connectors, install an inlet tube for each pump 

into the respective concentrate container, then 

install an outlet tube to the mixing reservoir or 

injection manifold.

Shown with optional PBX-100 series injection 

manifold designed for easy installation with a 

re-circulating pump for continuous recycling.

Connecting Pump Tubing

Summary of Contents for ADi

Page 1: ...Minimum Dose Size AD350 5mL Contents Dimensions 2 Installation Instructions 3 Connecting Pump Tubing 3 Connection to GrowControl GCX 4 GrowNET Hubs 4 Connection to SXHM Controller 5 Cross Over Cable...

Page 2: ...Agrowtek Inc www agrowtek com Technology to Help You Grow 2 Mounting Holes dia 0 201 n number of pump heads Dimensions 1 n 2 75 4 38 0 38 n 2 75 4 51 3 75...

Page 3: ...o avoid over tighteneing the screws and bending the flanges A 120Vac wall receptacle is required within 6ft of the pump for the power adapter Installation Instructions FROM SAMPLE PUMP WATER TANK RETU...

Page 4: ...g sensors and most relays directly over the CAT5 cable A DC jack on the hub provides 24Vdc power to the ports from the included wall power supply A terminal block power option is also available DIELEC...

Page 5: ...form a powerful autono mous pH and EC set point dosing system Operate a single dual or quad AgrowDose pump and configure each pump as an EC part or pH up or down part Automatically maintains pH and E...

Page 6: ...ects Agrowtek s devices to a computer s USB port for Connection to USB AgrowLINK Technology to Help You Grow AGROWtEK U S A MADE IN www agrowtek com GrowNET Device Hub TM USB AgrowLINKTM LX1 USB to Gr...

Page 7: ...not connected before you opened the program you can search for it by selecting USB AgrowLINK Detect AgrowLINK BatchMaster Software Setup Running a Recipe Each pump may have a setting for the dose vol...

Page 8: ...1 Alternate speeds and formats between 9 600 115 200 baud may be configured with the free AgrowLINK PC utility using a LX1 USB AgrowLINK and the cross over adapter supplied with the LX2 ModLINK MODBU...

Page 9: ...de 0 5A Motor 2 1mm jack center positive Motor Life Motor life and service intervals can be tracked by observing the pump motors accumulated run time which is tracked in seconds in a 32 bit unsigned i...

Page 10: ...rsion ASCII 8 char R 40016 Motor Speed Pump 1 0 100 16 bit unsigned R W 40101 Pump 2 16 bit unsigned 40102 Pump 3 16 bit unsigned 40103 Pump 4 16 bit unsigned 40104 Pump 5 16 bit unsigned 40105 Pump 6...

Page 11: ...s of time lost profits or savings or any other incidental consequential or special damages arising out of the use of or inability to use the product This disclaimer is made to the fullest extent allow...

Reviews: