AG-TRONIK
34
6.2.
Automatic regime
In automatic regime HD is regulated by AG-TRONIK, which needs following conditions to be met:
•
Proper hectare consumption (5.1).
•
correct selection of WSS constant (only in the case of using WSS) (5.3) and FC (5.4),
•
correct width of boom section width or number of nozzles (5.5.1 in 5.5.2),
•
correct nozzle selection (Instructions for Use of the Sprayer: General instructions for
Spraying),
•
correct minimum speed setting (5.8.2),
Handling of Operator:
•
Turn on AG-TRONIK, MAIN valve
and individual sections by pressing
key.
•
Turn on automatic regime by pressing
key.
•
WARNING! In the automatic mode, the
key must be on.
6.3.
SPRAYING GUIDELINES
6.3.1.
Preparation for Spraying
•
Check if the entered parameters in the program are correct,
•
partially fill the sprayer with water and test the flowmeter (when opening all the nozzle valves) on
the regulator - check the current flow in the AG-TRONIK display,
•
the sum of the flow of all operating nozzles must be equal to the flow shown on AG-TRONIK,
•
fill the tank with water and go to the spraying site,
•
fill the tank with a chemical preparation and mix it. All hand valves for mixing and the MAIN valve
are open during preparation of the chemical preparation. If the MAIN valve is closed, mixing
through the mixing nozzle does not take place (unless at some machines the mixing is carried
out via the mixing pump),
•
ensure the correct pressure for spraying,
•
if necessary, delete daily counters (ha, km, l).
•
check the validity of speed measurement of AG-TRONIK while driving.