background image

26/02/15 

 

 

Page 2 of 12 

 

 

 

AIR300 Hardware Manual for WAPro-G4

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
© Copyright 2015 by Agrident GmbH 
 
TB 
 
All rights reserved. No part of this publication may be reproduced, stored in a retrieval system, 
or transmitted, in any form or by any means, electronic, mechanical, photocopying, recording or 
otherwise, without prior written permission of Agrident GmbH. 
 
Agrident GmbH reserves the right to make changes to any and all parts of this documentation 
without obligation to notify any person or entity of such changes. 
 
February 2015 
 
Agrident GmbH 
Steinklippenstr. 10 
30890 Barsinghausen 
Germany 
Phone +49 (0) 51 05 582573-10 
Fax     +49 (0) 51 05 582573-17 
E-Mail: [email protected] 
www.agrident.com 

Summary of Contents for AIR300

Page 1: ...Agrident GmbH Steinklippenstr 10 D 30890 Barsinghausen Phone 49 5105 582573 10 Fax 49 5105 582573 17 AIR300 Hardware Manual for Motorola Workabout Pro G4 V26 02 15 ...

Page 2: ...lectronic mechanical photocopying recording or otherwise without prior written permission of Agrident GmbH Agrident GmbH reserves the right to make changes to any and all parts of this documentation without obligation to notify any person or entity of such changes February 2015 Agrident GmbH Steinklippenstr 10 30890 Barsinghausen Germany Phone 49 0 51 05 582573 10 Fax 49 0 51 05 582573 17 E Mail m...

Page 3: ...WAPro G4 Content 1 Introduction 4 2 Installation of the AIR300 LF RFID Reader 4 3 Reading transponders 6 4 Using an external antenna 8 5 Safety and care 11 6 Warranty 11 7 CE MARKING 12 8 FCC and IC digital device limitations 12 9 Trouble shooting 12 ...

Page 4: ...tion For all approval and safety information concerning the WORKABOUT Pro Generation 4please visit www motorola com or contact your local Motorola distributor 2 Installation of the AIR300 LF RFID Reader The following installation instructions refer to the WORKABOUT PRO G4 short version The instructions and pictures might vary for the long version and for other generations of the Workabout Pro Plea...

Page 5: ... top of the WORKABOUT PRO G4 Connect the USB connector Attach the AIR300 housing to the WORKABOUT PRO Please fix the AIR300 housing with the two provided M2 5x6 flat head screws If you are using the hand strap for the WORKABOUT PRO please use the provided 10 millimeter screws instead ...

Page 6: ...ry keys are required to allow Windows loading the appropriate USB Driver Please refer to the corresponding documents for details 3 Reading transponders If the AIR300 is activated from your software the LED is blinking red slowly If a transponder is being read the LED color will change to green RF is activated but no tag is in range RF is activated and a tag is in being read The green LED is blinki...

Page 7: ...ag type and tag orientation The following picture shows the field distribution of the AIR300 antenna As a result there is an optimum orientation and an unfavorable orientation Since Boluses also contain glass tags the reading orientation for injectables is the same as shown for the Boluses ...

Page 8: ...e changed The optional external antennas also contain a ferrite rod Hence the reading characteristics are similar to the AIR300 internal antenna 4 Using an external antenna Agrident also provides external antennas for the AIR300 for example the AEA580 External antennas extend the physical read range while the electrical characteristics are similar to the internal antenna This antenna can be connec...

Page 9: ...e notches in the cable connector have to match Insert the antenna connector into the plug in the correct position and press it down until it is snapped in The push pull locking style offers a quick and safe connection The AIR300 automatically detects the presence of an external antenna In this case only the external antenna will be used the internal one is disabled If the external antenna is remov...

Page 10: ...ot pull the cable this does not unplug the antenna connector After removing the external antenna connector from the reader it is very important to attach the protection cap again in order to protect the connector and the AIR300 electronics from moisture and dust Therefore please fold the protection cap back into the direction of the internal antenna and press it down into the initial position ...

Page 11: ...acturer is entitled to choose between up to two attempts at repair or supplying a replacement device on one occasion The warranty period for the repaired item or for a replacement item is 3 months but will always extend to the end of the original warranty period No further claims can be entertained especially claims for compensation for consequential losses This exclusion of liability does not app...

Page 12: ...accept any interference received including interference that may cause undesired operation FCC 15 21 Warning Statement Any changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment Canada CNR Gen Section 7 1 3 This device complies with Industry Canada licence exempt RSS standard s Operation is subject to the fol...