![AGRI TRONIX DIGI-STAR GT400 Operator'S Manual Download Page 5](http://html1.mh-extra.com/html/agri-tronix/digi-star-gt400/digi-star-gt400_operators-manual_2869498005.webp)
Technical
Specifications
D3831 Rev B
GT400 User’s Manual
1
TECHNICAL SPECIFICATIONS
SIZE
7.33” long x 5.25” high x 3.38” wide (186mm x
133mm x 85mm)
WEIGHT
2 lbs (.91 Kg)
HELP MESSAGES
Context sensitive help messages in 10
languages
Long messages are scrolled
TRANSDUCER EXCITATION
8 volts D.C. Nominal
Capable of driving eight 350 Ohms transducers
Short circuit proof
ATC
Auto Temperature Compensation of the internal
circuitry for high accuracy weighing
measurements
TRANSDUCER SIGNAL
Compatible with transducers having full scale
indicator transfer characteristics greater than
0.25 mv/v
“AUTO RANGE”
(Selectable) To increase display counts
at weight values of 300 and 600 display counts.
CONNECTOR
AMP plastic weather resistant circular
connector. Gold contacts.
POWER REQUIREMENTS
10.5 to 16.0 V.D.C.
160 mA nominal with four 350
Ω
L.C.
SET UP AND CALIBRATION
Via front panel
GROSS RANGE
999,999 max.display
LOW BATTERY WARNING
Enabled at 10.5V nominal
POUND/KILOGRAM
Selectable
DISPLAY
STD EZ 6 Digit LCD 1.0. high
DISPLAY RESOLUTION
.01, .02, .05, .1, .2, .5, 1, 2, 5, 10, 20, 50, 100
DISPLAY UPDATE RATE
Selectable: 1, 2, 3, 4 times/sec.
MAX. DISPLAY RESOLUTION
Adjustable to 40,000 counts max.
ZERO TRACKING
Selectable, On/Off
SPAN ACCURACY
±(.1% + .005%/ °F) or (.1% + 0.009% °C) full scale ± 1
output count
MOTION DETECTION
Selectable, On/Off
ZERO ACCURACY
(.005%/ °F.) or (0.009% °C) full scale ±1 output count
for 0.5 mv/v transducer
ENVIRONMENTAL ENCLOSURE
IP65, IEC 529
WEIGH ALGORITHM
4 internally selectable digital filters to optimize
performance
(General, Slow, Fast and Lock-on)
NON-VOLATILE MEMORY
EEPROM for balance
OPERATING TEMP
-29°C to 60°C
-20°F to 140°F