Electrical Interfaces
AGD155 Product Manual Rev.2.2
Page 20
3.4 Electrical Interfaces
This section provides a detailed description of all the power and signal interfaces of the product.
3.4.1 Interface X10: Main Power
Figure 8. Power Connector
Connector X10: PWR
Pin #
Name
Description
1
L1C
AC logic power
2
L2C
AC logic power
3
L1
AC main power
4
L2
AC main power
5
L3 (3-phase)
AC main power for 3-phase power input
6
PE
Protective earth
Connector manufacturer
Phoenix Contact
Mating connector part number
1942523
(Wurth Electronics equivalent: 691359740006)
(Degson equivalent: 2EDGKDM-5.08-6P-14)
Connector pitch
5.08 mm
Wiring
AWG 14, insulation rated for 600 V
Mains connections
Connect L1, L2 and L3 for main bus power.
If the main voltage is from a single-phase source, connect line and neutral to L1 and L2.
If the main voltage is from a three-phase source, connect the phase to L1, L2 and L3.
Connect line and neutral to L1C and L2C for logic power.
Warning - Hot plugging is not supported!
Plug or unplug the power connector only when power is off and after the bus LED has
turned off (red LED visible at the side of the product). Plugging the power connector
when power is on may cause power surges through connected devices and possibly
damage them.