Electrical Installation
AGD155 Product Manual Rev.2.2
Page 16
Figure 5. Power supply wiring
3.3.2 Circuit Breakers
Circuit Breaker Specifications
Feature
Specification
Circuit breaker type
Type C. 2-pole for L to N. 3-pole for 3-phase.
Fuse type
Time delay / slow blow
Current rating
AGD155 10A: 25 A
AGD155 6A: 10 A
AGD155 3A: 6 A
Voltage rating AC
600 VAC
Interrupt rating
minimum 10 kA
Example
: circuit breaker: SE iC60N 3P 6A C
3.3.3 AC Line filter
For proper product operation, an external AC line filter is required. Refer to Figure 5. Power supply
wiring. The AC line filter prevents external transients and spikes on the power line from entering the
product enclosure. Such interference may be caused by other AC powered devices being turned on
and off, and by motors running on the same power subsystem