APPLy Subsystem
3
U2300A Series USB DAQ Programming Guide
19
APPLy:SAWTooth
Syntax
APPLy:SAWTooth [<amplitude>, <offset>] (@<ch_list>)
This command is used to configure a sawtooth waveform pattern onto the
FIFO buffer. It outputs a sawtooth wave with the specified amplitude and
DC offset. The waveform is generated after executing the
OUTPut ON
command.
Supported Model
U2351A, U2353A, U2355A, U2356A, U2331A
Parameters
Remarks
•
Amplitude must be larger than zero.
•
Amp Offset
≤
10; Amplitude * (—1) + Offset
≥
—10.
Query Returned Format
<mode>, <amplitude>, <offset>
Name
Type
Range of Values
Default Value
<amplitude>
Float
<amplitude>: amplitude units [V]
10
<offset>
Float
<offset>: offset voltage [V]
0.0
<ch_list>
Numeric
U2331A: 201 through 202
N/A
Summary of Contents for U2300A Series
Page 8: ...VIII U2300A Series USB DAQ Programming Guide Contents ...
Page 18: ...1 Introduction to Programming 10 U2300A Series USB DAQ Programming Guide ...
Page 40: ...5 CONFigure Subsystem 32 U2300A Series USB DAQ Programming Guide ...
Page 60: ...6 IEEE 488 Common Command 52 U2300A Series USB DAQ Programming Guide ...
Page 70: ...7 MEASure Subsystem 62 U2300A Series USB DAQ Programming Guide ...
Page 84: ...8 OUTPut Subsystem 76 U2300A Series USB DAQ Programming Guide ...
Page 92: ...9 Root Commands 84 U2300A Series USB DAQ Programming Guide ...
Page 104: ...10 ROUTe Subsystem 96 U2300A Series USB DAQ Programming Guide See Also ROUTe CHANnel RSouRCe ...
Page 130: ...11 SENSe Subsystem 122 U2300A Series USB DAQ ...
Page 162: ...15 WAVeform Subsystem 154 U2300A Series USB DAQ Programming Guide ...
Page 168: ...16 Error Messages 160 U2300A Series USB DAQ Programming Guide ...