U2000 Series Models

Sensor model

Description

U2000A

10 MHz to 18 GHz, –60 dBm to +20 dBm USB Power Sensor, N-type (m)

U2001A

10 MHz to 6 GHz, –60 dBm to +20 dBm USB Power Sensor, N-type (m)

U2002A

50 MHz to 24 GHz, –60 dBm to +20 dBm USB Power Sensor, 3.5 mm (m)

U2004A

9 kHz to 6 GHz, –60 dBm to +20 dBm USB Power Sensor, N-type (m)

U2000H

10 MHz to 18 GHz, –50 dBm to +30 dBm USB Power Sensor, N-type (m)

U2001H

10 MHz to 6 GHz , –50 dBm to +30 dBm USB Power Sensor, N-type (m)

U2002H

50 MHz to 24 GHz, –50 dBm to +30 dBm USB Power Sensor, 3.5 mm (m)

U2000B

10 MHz to 18 GHz, –30 dBm to +44 dBm USB Power Sensor, N-type (m)

U2001B

10 MHz to 6 GHz, –30 dBm to +44 dBm USB Power Sensor, N-type (m)

Options and Accessories

Special Options

Option Number Description

U2001A-H03

U2001A sensor with extended frequency range, 3 MHz to 6 GHz

U2001A-H16

With 1K ohms input trigger impedance. Higher impedance is typically 
required when several instruments’ input trigger ports are connected 
in parallel for triggering purpose. Standard option has 50 ohms input 
trigger impedance.

U2001A-H25

U2001A sensor with extended power range, -60 dBm to +25 dBm

U2002A-H26

U2002A sensor with extended frequency range,  10 MHz to 26.5 GHz

Calibration Documentation

Option U200xx-A6J

• 

: ANSI Z540 compliance calibration test data including 

measurement uncertainties

Option U200xx-1A7

• 

: ISO17025 compliance calibration test data including 

measurement uncertainties

Documentation

A hard copy and CD version of the English language operating and service guide, 
programming guide, and the N1918A Power Analysis Assembly are shipped 
together with the USB power sensor as standard items.

Introduction

This confi guration guide describes the 
standard confi gurations, options, and 
compatible accessories for the U2000 
Series USB power sensors. Contact 
your local Agilent representative for 
more information.

Summary of Contents for U2000A

Page 1: ...02A 50 MHz to 24 GHz U2004A 9 kHz to 6 GHz U2000H 10 MHz to 18 GHz U2001H 10 MHz to 6 GHz U2002H 50 MHz to 24 GHz U2000B 10 MHz to 18 GHz U2001B 10 MHz to 6 GHz Agilent U2000 Series USB Power Sensors...

Page 2: ...ohms input trigger impedance Higher impedance is typically required when several instruments input trigger ports are connected in parallel for triggering purpose Standard option has 50 ohms input trig...

Page 3: ...ensor is provided as standard The 1 5 m cable can be replaced with 3 0 m Option 302 or 5 0 m Option 303 USB 2 0 Compliance cable length charges applied A 1 5 m trigger cable BNC male to SMB female 50...

Page 4: ...ars coverage R 50C 016 5 17025 Calibration Upfront Support Plan 5 years coverage Standard Shipped Components USB power sensor unit Power sensor cable 1 5 m 3 0 m or 5 0 m length Option 301 302 303 Tri...

Page 5: ...hannel operations Instrument Compatibility Compatible Model Compatible Firmware Revision PNA X N5242A PNA E8361A C E8362B C E8363B C E8364B C PNA L N5230A C A 07 50 13 and above Handheld Spectrum Anal...

Page 6: ...N 4 Fundamental of RF and Microwave Power Measurements Part 4 application notes 1449 4 literature number 5988 9216EN 5 Steps for Making Better Power Measurements application note 64 4D literature numb...

Page 7: ...rtners www agilent com find channelpartners Get the best of both worlds Agilent s measurement expertise and product breadth combined with channel partner convenience For more information on Agilent Te...