Programming Command Reference
5
N9360A Multi UE Tester W-CDMA Programming Manual
5-59
TESTs:MANual:CPichRScp:MEASure
This command starts CPICH RSCP measurement in Connection
status.
Command Reference for Manual Test Result
The following query commands return measurement result values
of the Manual Test.
PRACH Power Measurement
TESTs:MANual:RESults:PRACHpower?
This query command returns the PRACH Power measurement
result values,
<int 1>
,
<int 2>
, and
<real 3>
. Each value is
separated by a comma.
•
<int 1>
(1 digit) is
0
if measurement result is within the
measurement range, or
1
if measurement result is out of
range or PRACH Power is not measured.
•
<int 2>
(1 digit) is the test result for the pass (0) or fail (1).
•
<real 3>
(up to 5 letters) is the measured data ranging from
-99.9
to
+99.9
in dBm. If measurement result is out of range
or the PRACH Power is not measured, the value
-99.9
is
returned.
TX Power Measurement
TESTs:MANual:RESults:TXPower?
This query command returns the TX Power measurement result
values,
<int 1>
,
<int 2>
, and
<real 3>
. Each value is separated
by a comma.
•
<int 1>
(1 digit) is
0
if measurement result is within the
measurement range, or
1
if measurement result is out of
range or the TX Power is not measured.
•
<int 2>
(1 digit) is the test result for the pass (0) or fail (1).
•
<real 3>
(5 letters) is the measured data ranging from
-99.9
to
+99.9
dBm. If any measurement is overflow,
underflow or not made, the value
-99.9
is returned.
Summary of Contents for N9360A
Page 1: ...Agilent Technologies Agilent N9360A Multi UE Tester W CDMA Programming Manual...
Page 4: ...1 4 N9360A Multi UE Tester W CDMA Programming Manual 1 THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 8: ...8 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...
Page 12: ...6 N9360A Multi UE Tester W CDMA Programming Manual THIS PAGE IS INTENTIONALLY LEFT BLANK...