![Agilent Technologies N4968A User Manual Download Page 17](http://html.mh-extra.com/html/agilent-technologies/n4968a/n4968a_user-manual_2867405017.webp)
Performance Specifications
16
Clock and Data Demultiplexer 44 Gb/s User Guide
3.2
N4968A Clock and Data Demultiplexer Specifications
Table 2. N4968A clock and data demultiplexer specifications
Parameter
Specification
Data input
Data rate
3.5 to 44 Gb/s
Data amplitude
150 to 1000 mV p-p single-ended
Maximum DC voltage ±0.5 V
Interface
Differential. DC coupled, 50
Ω nominal, 1.85 mm female
connectors. Can be used single-ended if unused input is
terminated with 50 Ω load.
Data output
Data rate
0.875 to 11 Gb/s
Data amplitude
> 210 mV p-p typical
Interface
Single-
ended outputs. AC coupled, 50 Ω nominal, 2.92 mm
female connectors.
Clock input
Type
Half-rate clock for demux-by-4 mode
Full-rate clock for demux-by-2 mode
Frequency
1.75 to 22 GHz for demux-by-4 mode
1
3.5 to 22 GHz for demux-by-2 mode
2
Clock amplitude
+2 to +10 dBm (0.8 to 2 V p-p)
Interface
Single-ended input. AC coupled, 50
Ω nominal, 2.92 mm
female connector.
Divided clock outputs
Division ratios
1, 2, 4, 8, 16, 32, and 64
Clock amplitude
> −5 dBm (355 mV p
-p) typical
Interface
Differential outputs. AC coupled, 50 Ω nominal, SMA mm
female connectors. Can be used single-ended if unused input
is terminated with 50 Ω load.
1
Demux-by-4 mode data rate is 3.5 to 44 Gb/s.
2
Demux-by-2 mode data rate is 3.5 to 22 Gb/s.
This Manual:http://www.manuallib.com/agilent/n4968a-demultiplexer-user-guide.html