Bit Rate - Reference
The
Bit Rate Setup
window contains the following elements:
Clock Source
Clock source can be one of the following:
• Internal: The clock generator uses the internal oscillator.
• 10 MHz Ref: The clock generator uses the 10 MHz Reference that must be
connected to the 10 MHz Ref Input.
• External: The pattern generator uses the external clock that must be connected
to the Clock Input. You can choose between
.
• External PLL: The pattern generator uses the external clock that must be
connected to the Clock Input. This clock is routed internally through a PLL. You
“Automatic and Manual Mode” on page 143
Automatic and Manual Mode
The
Manual Adjustment
checkbox is available if you have chosen an external clock
source.
In automatic mode, the external clock frequency is continually measured. When
the external clock frequency changes, the bit rate changes as well.
In manual mode, you can enter the expected frequency or press the
Measure &
Set
button.
Measure & Set
requires that the external clock generator is connected
and active. Its frequency is measured once and determines the bit rate. When the
external clock frequency changes,
PG Clock Loss
is signaled.
External Clock Divider
The internal clock (i.e. the bitrate) is the external clock divided by the value
specified in the clock divider field. The external clock divider field is available if you
have closen an external clock source.
Setting up the Pattern Generator
4
Agilent J-BERT N4903B High-Performance Serial BERT
143
Summary of Contents for J-BERT N4903B
Page 1: ...S Agilent J BERT N4903B High Performance Serial BERT User Guide s Agilent Technologies ...
Page 10: ...10 Agilent J BERT N4903B High Performance Serial BERT ...
Page 36: ...1 Planning the Test 36 Agilent J BERT N4903B High Performance Serial BERT ...
Page 60: ...2 Setting up External Instrument s 60 Agilent J BERT N4903B High Performance Serial BERT ...
Page 120: ...3 Setting up Patterns 120 Agilent J BERT N4903B High Performance Serial BERT ...
Page 360: ...6 Advanced Analysis 360 Agilent J BERT N4903B High Performance Serial BERT ...
Page 468: ...8 Jitter Tolerance Tests 468 Agilent J BERT N4903B High Performance Serial BERT ...
Page 524: ...9 Solving Problems 524 Agilent J BERT N4903B High Performance Serial BERT ...
Page 566: ...10 Customizing the Instrument 566 Agilent J BERT N4903B High Performance Serial BERT ...