0V (Disable)
C A U T I O N
Before clicking this button, ensure that your device's inputs tolerate ground
potential.
Use this button to clamp the pattern generator's output ports (Data, Clock, Aux
Data and Tigger/Ref Clock) to ground. You can see the status of the outputs in the
display area of the pattern generator.
Note that you can also use the buttons present below the display, to enable or
disable the output ports.
This function can be useful in case you want to connect or disconnect a device to
any of the output ports to prevent any damage.
Output Blanking
When the generator is set up to generate a pattern, use this checkbox to activate
the
Aux In
port of the pattern generator. You can then connect a signal to this port
and operate the pattern generator in output blanking mode.
If a logic low signal is supplied to the
Aux In
port, pattern A is sent to the output
port. If a logic high is supplied, no data is sent to the output port.
This function is the same as the output blanking function in the
Alternate Pattern
Control
dialog box (see
for details). However, this function
also works with standard patterns.
When the generator is set up to generate a sequence, this checkbox is disabled.
You can connect a signal to the
Aux In
port of the pattern generator. The reaction
on this signal (for example, start sequence execution, or break loop) is defined in
the SequenceExpression. For details see
“User-Defined Sequences - Concepts ”
Electrical Idle
Use this checkbox to activate Electrical Idle (Out Of Band Signaling; OOB). Electrical
Idle is controlled via the existing Error Add Input, which will loose its error insertion
functionality when used for Electrical Idle.
N O T E
The "Electrical Idle" checkbox is invisible when the N4876A Multiplexer is
connected to the N4903B Serial BERT.
4
Setting up the Pattern Generator
138
Agilent J-BERT N4903B High-Performance Serial BERT
In Pattern Mode
In Sequence Mode
Summary of Contents for J-BERT N4903B
Page 1: ...S Agilent J BERT N4903B High Performance Serial BERT User Guide s Agilent Technologies ...
Page 10: ...10 Agilent J BERT N4903B High Performance Serial BERT ...
Page 36: ...1 Planning the Test 36 Agilent J BERT N4903B High Performance Serial BERT ...
Page 60: ...2 Setting up External Instrument s 60 Agilent J BERT N4903B High Performance Serial BERT ...
Page 120: ...3 Setting up Patterns 120 Agilent J BERT N4903B High Performance Serial BERT ...
Page 360: ...6 Advanced Analysis 360 Agilent J BERT N4903B High Performance Serial BERT ...
Page 468: ...8 Jitter Tolerance Tests 468 Agilent J BERT N4903B High Performance Serial BERT ...
Page 524: ...9 Solving Problems 524 Agilent J BERT N4903B High Performance Serial BERT ...
Page 566: ...10 Customizing the Instrument 566 Agilent J BERT N4903B High Performance Serial BERT ...