Agilent Technologies 70341A Installation Manual Download Page 13

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

Summary of Contents for 70341A

Page 1: ... underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respective ...

Page 2: ...rd company brand name The brand name has now been changed to Agilent Technologies The two products are functionally identical only our name has changed The document still includes references to Hewlett Packard products some of which have been transitioned to Agilent Technologies Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 3: ...tralia tel 1 800 629 485 fax 61 3 9210 5947 Asia Call Center Numbers Country Phone Number Fax Number Singapore 1 800 375 8100 65 836 0252 Malaysia 1 800 828 848 1 800 801664 Philippines 632 8426802 1 800 16510170 PLDT Subscriber Only 632 8426809 1 800 16510288 PLDT Subscriber Only Thailand 088 226 008 outside Bangkok 662 661 3999 within Bangkok 66 1 661 3714 Hong Kong 800 930 871 852 2506 9233 Tai...

Page 4: ...gies 70341A Frequency Extension Module Manufacturing Part Number 70341 90003 Printed in USA January 1992 Copyright 1992 2001 Agilent Technologies Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 5: ... Do not proceed beyond a warning note until the indicated conditions are fully understood and met CAUTION Caution denotes a hazard It calls attention to a procedure that if not correctly performed or adhered to could result in damage to or destruction of the instrument Do not proceed beyond a caution sign until the indicated conditions are fully understood and met NOTE Note calls out special infor...

Page 6: ...s instrument product is warranted against defects in material and workmanship for a period of three years from date of shipment During the warranty period Agilent Technologies will at its option either repair or replace products which prove to be defective For warranty service or repair this product must be returned to a service facility designated by Agilent Technologies Buyer shall prepay shippi...

Page 7: ...tenance NO OTHER WARRANTY IS EXPRESSED OR IMPLIED AGILENT TECHNOLOGIES SPECIFICALLY DISCLAIMS THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE EXCLUSIVE REMEDIES THE REMEDIES PROVIDED HEREIN ARE BUYER S SOLE AND EXCLUSIVE REMEDIES AGILENT TECHNOLOGIES SHALL NOT BE LIABLE FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES WHETHER BASED ON CONTRACT TORT...

Page 8: ...uld be veri ed through the procedure Verifying the HP 70340A 41A Functionality in the HP 70340A 41A User s Guide and or through the incoming inspection procedure in the HP 70340A 41A Calibration Guide Signal generator applications and reference material are in the HP 70340A 41A User s Guide See the Learning Products Map at the end of this book for a complete list of documentation pertaining to the...

Page 9: ...e HP 70340A refers to the HP 70340A modular signal generator signal generator refers to the HP 70340A modular signal generator MMS refers to the HP 70000 Modular Measurement System module refers to any MMS module mainframe refers to your mainframe or display HP 70001A HP 70004A HP 70205A or HP 70206A 4hard key5 refers to keys dedicated to one function as labeled NNNNNNNNNNNNNNNNNNNNNNN softkey ref...

Page 10: ...r front panel operation a display The HP 70341A frequency extension module is shown being installed into the mainframe This example MMS con guration shows the 1 HP 70001A mainframe 2 HP 70206A display module 3 HP 70340A signal generator and 4 HP 70341A frequency extension module v Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 11: ... HP 70341A are made from the rear panels Refer to the procedure To Make Rear Panel Connections in chapter 1 for the connections between the two modules vi Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 12: ... 2 If You Encounter a Problem shows you what to do in the event that you do have trouble installing the HP 70341A Chapter 3 Reference provides alphabetized entires about module features speci cations accessories options etc which pertain to the installation procedures in this book Chapter 4 Legal and Regulatory Information contains safety RFI type acceptance SCPI conformance and product warranty i...

Page 13: ...Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 14: ...ion fan does not start 2 6 If the HP 70341A ERR LED remains on after the power up test is complete 2 7 If the HP 70340A ERR LED or the display E remains on after the power up test is complete 2 8 If either the display HP MSIB or mainframe I O Check Indicator remains on 2 9 If the mainframe CURRENT indicator remains on 2 10 If the display does not accept the 500 MHz cw frequency data input 2 11 If ...

Page 15: ... 13 Option 0BW Add Assembly level Service Documentation 3 13 Option 0BV Add Component level Service Documentation 3 13 Speci cations HP 70340A 41A 3 14 Frequency 3 14 RF Output 3 15 Spectral Purity 3 17 Modulation 3 20 General 3 24 Physical Dimensions 3 24 Rear Panel Connectors 3 26 Options 3 27 4 Legal and Regulatory Information Safety Considerations 4 3 Before Applying Power 4 3 Safety Earth Gro...

Page 16: ...ASSISTANCE Index Contents 3 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 17: ...Contents Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 18: ...1 Installing the HP 70341A Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 19: ...A refer to the HP 70340A 41A Calibration Guide for performance veri cation or incoming inspection procedures If you have di culty running any of these procedures the chapter If You Encounter a Problem lists commonly encountered problems and solutions that allow you to quickly get back to work The tools required for installation include 8 mm hex ball driver HP part number 8710 1307 torque wrench si...

Page 20: ...hich you are reading now 5 Options If you ordered the option s below you will also receive Option 0B2 HP 70341A Installation Guide Option 0BW HP 70341A Service Guide Option 0BV HP 70341A Component Level Information Manual Note that a power cable is not shipped with the HP 70341A It is supplied with your MMS mainframe or stand alone display 2 Keep the packaging materials and shipping container for ...

Page 21: ... 70341A This procedure assumes that you have already installed the HP 70340A modular signal generator into the MMS If you have not installed the HP 70340A refer to the HP 70340A 41A User s Guide procedure Installing the Signal Generator 1 4 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 22: ...h the HP 70205A Display and HP 70001A Mainframe In this con guration the 3 8 display module the 4 8 signal generator module and the 1 8 frequency extension module together ll all slots in the mainframe Other MMS con gurations are possible as long as the HP 70341A is to the right of and immediately adjoining the HP 70340A 1 5 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE...

Page 23: ...e Display On the rear panel of the HP 70205A Display On the rear panel of the HP 70206A Graphics Display 3 Check that the LINE voltage selectors are set to the voltage of your power source The selector should be set as follows 115 V position for 90 to 132 V ac line input voltages at 50 60 or 400 Hz 230 V position for 198 to 264 V ac line input voltages at 50 or 60 Hz 1 6 Artisan Technology Group Q...

Page 24: ...an its master To change the HP MSIB address of a module refer to the procedure To Check and Set the HP 70341A HP MSIB Address Note that the Display Con guration address switches on the back of the Graphics Display are for the display instrument only These switches do not set the address of the system or any module within the system 6 Connect the power cable s to the system and then to the power so...

Page 25: ...locate and determine the module address in case you want to change it If you do change the HP MSIB address a nonconductive stylus such as a toothpick is useful for setting the switches 1 8 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 26: ...ddress error reporting and access to HP IB are allowed Because the HP 70341A is a slave to the HP 70340A its row address cannot be 0 Legal row addresses for the HP 70341A are 1 through 8 Set switches Column 1 Column 2 Column 3 Column 4 and Column 5 to the same settings as the HP 70340A switches so that the column address of the HP 70341A equals the column address of the HP 70340A Both the HP 70340...

Page 27: ... properly install the HP 70341A into your mainframe The procedure is simple the only tool required is an 8 mm hex ball driver which is provided with your mainframe and or display 1 10 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 28: ...ule personal injury or damage to the instrument can occur On some MMS mainframe models the door will not open unless the LINE switch is o 2 Open the front panel mainframe or display door 3 Slide the HP 70341A into a 1 8 single slot adjoining and to the right of the HP 70340A 4 Using an 8 mm hex ball driver tighten the hex nut latch and close the front panel door 1 11 Artisan Technology Group Quali...

Page 29: ...5 lbs in torque wrench for the two semi rigid cable connectors Refer to the entry Accessories included in chapter 3 for cable part numbers Refer to the Connectors entry for details about working with the rear panel SMA and SMB connectors 1 12 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 30: ...nt panel input This procedure requires an MMS display for front panel instrument operation If you are not using a display follow steps 1 through 3 of this procedure and then refer to the Generating Signals chapter in the HP 70340A 41A User s Guide for examples of HP IB code for generating signals 1 13 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 31: ... data lost at power on 1803 3 If the display does not show the HP 70340A Signal Gen screen press FFFFFFFFFFFFFFFFFFFFFFFFFFFFFFFF MORE ERRORS until it does 4 Press 4MENU5 in order to turn o the ERR LED and return to the HP 70340A front panel menus Note that if you have just installed or removed the HP 70341A error message 1803 does not imply a true error in instrument operation Its purpose is to r...

Page 32: ...2 If You Encounter a Problem Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 33: ...fer to the Troubleshooting section of the Installation and Veri cation Manual for your MMS mainframe or contact the nearest Hewlett Packard o ce for service The procedures in this chapter do not require either internal access to the instrument or any external test equipment The only tool required for these procedures is an 8 mm hex ball driver 2 2 Artisan Technology Group Quality Instrumentation G...

Page 34: ...earest Hewlett Packard o ce and the carrier 2 Keep the shipping materials for the carrier s inspection 3 Refer to the procedure If you need to return the HP 70341A for repair 2 3 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 35: ...nnected Check that the LINE voltage selector is set to the correct voltage 115 V or 230 V for the power source The LINE voltage selector switch is located on the left hand side of the HP 70004A display on the bottom of the HP 70001A mainframe on the rear panel of the HP 70206A and HP 70205A displays Line Voltage Selection Location 2 4 Artisan Technology Group Quality Instrumentation Guaranteed 888...

Page 36: ...use a continuity light or an ohmmeter to check the fuse An ohmmeter should read very close to zero ohms if the fuse is good Visual inspection of the fuse is not a sure check that the fuse is good If the fuse is bad replace it and attempt power up W A R N I N G For continued protection against re hazard replace the fuse with one that is the same type and rating Remove the HP 70341A from the MMS and...

Page 37: ...oving the HP 70341A and recycling power Refer to the display or mainframe installation manual for information regarding proper operation Contact the nearest Hewlett Packard o ce for service If the mainframe power light is on but the ventilation fan does not start Set the mainframe LINE Mains switch to OFF Check for blockage of the fan intakes at the bottom rear of the mainframe Refer to your MMS m...

Page 38: ...ins on after the power up test is complete Refer to the HP 70341A Service Guide or contact your local Hewlett Packard o ce for service 2 7 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 39: ...the display E is not ashing If any error indicator is ashing this indicates that the module cannot talk over the HP MSIB bus If more than one error indicator is ashing the mainframe HP MSIB is faulty a module is faulty or the HP MSIB cables are probably faulty Check that there are no mainframe error messages Mainframe error messages will appear on the display Refer to your mainframe operating and ...

Page 40: ...HP MSIB address In order to change a module HP MSIB address refer to the procedure To Check and Set the HP MSIB Address in chapter 1 Check for a faulty mainframe or stand alone display by removing all of the HP MSIB cables and noting whether or not the indicator light remains on If the indicator light remains on the mainframe or display is probably faulty If the indicator light turns o the problem...

Page 41: ...eps 1 Remove one module from the mainframe 2 Cycle the power If the indicator turns o the removed module is faulty If the indicator remains on continue to remove modules until the module causing the indicator to light is identi ed If the indicator remains on after all modules are removed the mainframe is probably faulty 2 10 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE...

Page 42: ...NNNNNNNNNNNNNNNN address map softkey and the Knob in order to view each module s HP MSIB address using the front panel screen If the HP MSIB address switches are not set correctly 1 Correctly reset the HP MSIB addresses so that the HP 70340A can address the HP 70341A Refer to the procedure To Check and Set the HP 70341A HP MSIB Address for help in determining or setting the HP MSIB addresses 2 Cyc...

Page 43: ...a blue repair card is not available send the following information with the returned instrument 1 Type of service required 2 Description of the problem state if the problem is constant or intermittent 3 Name and phone number of technical contact person 4 Return address 5 Model number of returned instrument 6 Full serial number of returned instrument 7 List of any accessories returned with instrume...

Page 44: ...ng materials can be ordered from any Hewlett Packard o ce 4 If the original shipping materials are not available instruments can be repackaged for shipment using the following instructions 1 Wrap the instrument in antistatic plastic to reduce the possibility of ESD caused damage 2 For instruments that weigh less than 54 kg 120 lb use a double walled corrugated cardboard carton of 159 kg 350 lb tes...

Page 45: ... foam is not available the best alternative is S D 240 Air Cap TM from Sealed Air Corporation Commerce California 90001 Air Cap is a plastic sheet lled with 1 1 4 inch air bubbles Use the pink antistatic Air Cap to reduce static electricity Wrap the instrument several times in this material to protect the instrument and prevent it from moving in the carton 5 Seal the carton with strong nylon adhes...

Page 46: ...3 Reference Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 47: ...electrical speci cations for the HP 70340A and HP 70341A combination are listed here as well as other speci cations and options that apply speci cally to the HP 70340A For easy reference all entries in this chapter are alphabetized 3 2 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 48: ...0341A Installation Guide which you are reading now 5 options If you ordered the option s below you will also receive Option 0B2 HP 70341A Installation Guide Option 0BW HP 70341A Service Guide Option 0BV HP 70341A Component Level Information Note that a power cable is not shipped with the HP 70341A It is supplied with your MMS mainframe or stand alone display 3 3 Artisan Technology Group Quality In...

Page 49: ...00C HP MSIB Cable 6 0 meter HP 70800D HP MSIB Cable 30 meter HP 70800E SMB push on Cable 15 cm rear panel connections 08753 60061 SMB push on Cable 30 cm rear panel connections 5061 1022 SMA ex coax Cable inter module connections 5061 9038 SMA ex coax Cable mainframe connections 5061 9039 SMB f to BNC m Cable 85680 60093 SMA f to SMA m Cable 8120 1578 8 mm hex ball Driver module removal installati...

Page 50: ...kits refer to your mainframe or display installation manuals For documentation pertaining to the HP 70340A and the HP 70341A refer to the Learning Products Map at the end of this book 3 5 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 51: ...ductor and the outer conductor is undamaged clean and free of contamination from metal particles 3 If necessary clean the cable ends using a cotton swab lightly moistened with alcohol 4 Inspect the mating connectors and clean them if necessary 5 Allow the alcohol to evaporate completely before assembling the connectors 6 Retract the outer nuts away from the ends of the cable 7 Carefully insert bot...

Page 52: ... 11 Tighten both connector nuts nger tight 12 Using a 5 16 inch torque wrench tighten each connector nut to a value of 8 0 6 1 0 lbs in T o Disconnect Semi rigid Cables 1 Disconnect 3 5 mm SMA connectors from the mating connector by loosening the 5 16 inch nut until it is completely free of the mating connector Loosen the nuts at both ends of the cable before attempting to remove either end 2 When...

Page 53: ... will not separate place the jaws of a pair of long nose pliers under the connector body Use the jaws as a fulcrum to lift the connector away from the rear panel Use a piece of tape or other material under the pliers to avoid scratching the surface to which the connector is mounted C A U T I O N Exert force only on the body of the connector Do not pull on the cable These connectors are easily dama...

Page 54: ... gure shows an example of a static safe workstation using two types of ESD protection 1 conductive table mat and wrist strap combination and 2 conductive oor mat and heel strap combination These methods may be used together or separately A list of static safe accessories and their part numbers is given on the following pages Static Safe Workstation 3 9 Artisan Technology Group Quality Instrumentat...

Page 55: ...connections Do not touch the edge connector contacts or trace surfaces with bare hands Always handle board assemblies by the edges PC board assembly edge connector contacts may be cleaned by using a lint free cloth with a solution of 80 electronics grade isopropyl alcohol and 20 deionized water This procedure should be performed at a static safe workstation T est Equipment Before connecting any co...

Page 56: ...ic control mat 6m x 1 2m 2 ft x 4 ft 4 6m 15 ft ground wire wrist strap and attachment cord HP Part Number 9300 0980 Wrist strap cord 1 5m 5 ft HP Part Number 9300 0985 Wrist strap large HP Part Number 9300 0986 Wrist strap small HP Part Number 9300 1169 ESD heel strap reusable 6 to 12 months HP Part Number 9300 0793 Shoe ground strap one time use only 3 11 Artisan Technology Group Quality Instrum...

Page 57: ...this option Option W32 Three Y ears Return to HP Calibration Service Consult your HP sales representative for details on this option Option W34 Three Y ear Mil std Calibration Service Consult your HP sales representative for details on this option Longer term warranty and calibration services are available Please consult your HP sales representative for details 3 12 Artisan Technology Group Qualit...

Page 58: ...ation Guide Option 0BW Add Assembly level Service Documentation If option 0BW is ordered the shipment contains a set of service documentation This includes the HP 70341A Service Guide the HP 70340A 41A Calibration Guide and the Calibration Software Note that the calibration and service documentation is not shipped with the Frequency Extension Module if option 0BW is not ordered Option 0BV Add Comp...

Page 59: ...imating instrument capability in your application by describing typical but not warranted performance Frequency Range HP 70340A Modular Signal Generator 1 0 to 20 0 GHz HP 70341A Frequency Extension Module 10 MHz to 1 GHz HP 70341A can only be used in combination with the HP 70340A Resolution 1 kHz 1 Hz with Option 1E8 Stability with external high stability timebase Aging Rate same as external ref...

Page 60: ... with Option 1E1 0 0101 GHz 13 dBm 13 dBm 1018 GHz 11 dBm 10 dBm 18020 GHz 10 dBm 8 dBm Typical maximum available output power from 1 to 20 GHz at 25 C with output step attenuator Option 1E1 installed 3 15 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 61: ...Accuracy over all speci ed temperatures and power levels 10 MHz to 50 MHz 62 3 dB 50 MHz to 20 GHz 62 0 dB The use of Type N RF connectors above 18 0 GHz degrades speci cation typically by 0 2 dB Flatness 60 5 dB The use of Type N RF connectors above 18 0 GHz degrades speci cation typically by 0 2 dB Level Switching Time 15 ms without step attenuator range change Attenuator range changes occur at ...

Page 62: ... dBc Hz O sets Carrier Freq 100 Hz 1 kHz 10 kHz 100 kHz 500 MHz 070 086 0103 0119 2 GHz 066 074 091 0107 10 GHz 069 075 079 0101 18 GHz 063 070 073 099 Phase noise decreases 6 dB octave below 500 MHz and reaches a oor of 0140 dBc Hz 3 17 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 63: ...lity timebase Harmonics 055 dBc at output levels 6 dBm 0 01 to 20 GHz Typical 2nd harmonic levels measured at output power of 6 dBm Non Harmonic Spurious 3 kHz 060 dBc includes power supply and frequency synthesis spurious Non Harmonic Spurious 3 kHz 050 dBc Sub Harmonics None 3 18 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 64: ...CW mode At 1 GHz 15 Hz in 50 Hz 15 kHz bandwidth Residual FM decreases 6 dB per octave below 1 GHz AM Noise Floor at 0 dBm and o sets greater than 5 MHz from carrier 0150 dBm Hz 1 20 GHz 0140 dBm Hz 0 01 1 GHz 3 19 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 65: ... peak at 0 dBm Pulse Width Compression 6150 ns 615 ns 65 ns Pulse Delay Video out to RF out 1 s 200 ns 125 ns 100 ns Pulse Modulation On O Ratio 80 dB Typical pulse modulation on o ratio at 8 dBm Maximum Pulse Repetition Frequency 3 MHz Minimum Pulse Duty Cycle No restrictions on duty cycle Pulse Level Accuracy relative to CW 61 0 dB Pulse Overshoot 10 Input Impedance 50 nominal TTL drive levels 3...

Page 66: ...ce Pulse Repetition Frequency 3 Hz to 3 MHz Pulse Repetition Interval PRI 300 ns to 419 ms Pulse Width Tw 25 ns to 419 ms Variable Pulse Delay free run mode Td 6419 ms from sync pulse to video modulation Variable Pulse Delay triggered with delay doublet modes Td 225 ns to 419 ms with 625 ns jitter Pulse Width Delay PRI Resolution 25 ns Pulse Delay Video to RF Tm Nominally 20 ns 1 to 20 GHz All pul...

Page 67: ...0 CARRIER FREQUENCY 10 16 MHz 16 64 MHz 64 MHz 256 MHz 256 MHz 1 GHz 1 20 GHz FM Sensitivity 40 kHz V 80 kHz V 320 kHz V 1 25 kHz V 5 MHz V FM Sensitivity Accuracy 625 at 100 kHz Incidental AM 5 FM Input Impedence 600 nominal Harmonic Distortion 1 1 MHz peak deviation 100 kHz rate 1 Maximum deviation decreases by a factor of 2 for each octave below 256 MHz 3 22 Artisan Technology Group Quality Ins...

Page 68: ...vel 1 GHz 1 20 GHz rise time 10 s 5 s fall time 20 s 5 s Input Impedance 5000 nominal Maximum Leveled Output Power in Log AM Mode relative to CW 1 GHz 1 4 GHz 4 GHz 0 dB 4 5 dB 1 0 dB Typical log AM error deviation from desired depth at 25 C for carrier frequencies between 1 0 and 20 GHz 3 23 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 69: ...ease consult your HP sales representative for details Environmental Operating Temperature Range 0 to 55 C EMC Meets or exceeds EN 55011 CISPR 11 1990 Class A and Mil Std 461C Part 2 RE02 CE03 CS02 RS03 Physical Dimensions Net Weight HP 70340A 9 kg 20 lb HP 70341A 2 5 kg 5 lbs Shipping HP 70340A 15 kg 30 lb HP 70341A 6 kg 12 lbs Size HP 70340A 4 8 MMS module width 148 5 mm H 2 192 8 mm W 2 477 5 mm...

Page 70: ...Reference Speci cations HP 70340A 41A HP 70340A Dimensions HP 70341A Dimensions 3 25 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 71: ...MB connector outputs the 10 MHz external reference signal nominally 3 dBm for use as an external reference signal EXTERNAL ALC OUTPUT SMB connector outputs external ALC drive signal from the front panel EXT ALC input connector to the frequency extension module ALC CONTROL OUTPUT SMB connector supplies a 010 to 10 V signal as a reference for leveling the 01 to 1 0 GHz output signal of the HP 70341A...

Page 72: ...PUT connector PULSE INPUT SMB connector accepts pulse modulation drive signal from the HP 70340A rear panel PULSE OUTPUT connector Options There are several electrical mechanical warranty and documentation options available for the HP 70340A Electrical Options There are three electrical options available for the Signal Generator These options are as follows Option 1E1 Add Output Step Attenuator If...

Page 73: ...al inverted external free run internal gated triggered with delay and pulse doublet Pulse rise and fall times are typically 5 ns minimum leveled pulse width is 25 ns and on o ration is 80 dB Option 1E8 1 Hz Frequency Resolution Consult your HP sales representative for details on availability and retro t information Option 1E9 3 5 mm RF Output Connector If option 1E9 is ordered the RF OUTPUT connec...

Page 74: ...4 Legal and Regulatory Information Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 75: ...d Regulatory Information This chapter contains information pertaining to safety SCPI conformance and the warranty 4 2 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 76: ...ve earth terminal Before Applying Power Verify that the product is set to match the available line voltage and the correct fuses are installed Safety Earth Ground An uninterruptible safety earth ground must be provided from the main power source to the product input wiring terminals power cable or supplied power cable set 4 3 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURC...

Page 77: ...re for use by service trained personnel only To avoid dangerous electric shock do not perform any servicing unless quali ed to do so Adjustments described in the manual are performed with power supplied to the system s instruments while protective covers are removed Energy available at many points may if contacted result in personal injury Capacitors inside the system s instruments might still be ...

Page 78: ...nd a WARNING sign until the indicated conditions are fully understood and met C A U T I O N The CAUTION sign denotes a hazard It calls attention to a procedure practice or the like which if not correctly performed or adhered to could result in damage to or destruction of part or all of the product Do not proceed beyond a CAUTION sign until the indicated conditions are fully understood and met 4 5 ...

Page 79: ...pter 7 Programming Commands of the HP 70340A 41A User s Guide The table in Chapter 10 of the HP 70340A 41A User s Guide lists all of the commands and queries that the Signal Generator understands and whether they are SCPI approved SCPI con rmed or non SCPI The commands and queries that are labeled IEEE 488 2 Required and IEEE 488 2 Optional are always non SCPI If you need more information about SC...

Page 80: ...erti es that its calibration measurements are traceable to the United States National Institute of Standards and Technology NIST to the extent allowed by the Institute s calibration facility and to the calibration facilities of other International Standards Organization members 4 7 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 81: ...oftware and rmware designated by HP for use with an instrument will execute its programming instructions when properly installed on that instrument HP does not warrant that the operation of the instrument or software or rmware will be uninterrupted or error free LIMITATION OF W ARRANTY The foregoing warranty shall not apply to defects resulting from improper or inadequate maintenance by Buyer Buye...

Page 82: ...EIN ARE BUYER S SOLE AND EXCLUSIVE REMEDIES HP SHALL NOT BE LIABLE FOR ANY DIRECT INDIRECT SPECIAL INCIDENTAL OR CONSEQUENTIAL DAMAGES WHETHER BASED ON CONTRACT TORT OR ANY OTHER LEGAL THEORY 4 9 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 83: ...r customer assistance agreements are available for Hewlett Packard products For any assistance contact your nearest Hewlett Packard Sales and Service O ce 4 10 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 84: ...ue Du Canada Hewlett Packard Strasse Eskdale Road Winnersh Triangle 1217 Meyrin 2 Geneva Zone D Activite De Courtaboeuf 61352 Bad Homburg v d H Wokingham Berkshire RG41 5DZ Switzerland F 91947 Les Ulis Cedex Germany England 41 22 780 8111 France 49 6172 16 0 44 734 696622 33 1 69 82 60 60 INTERCON FIELD OPERATIONS Headquarters Australia Canada China Hewlett Packard Company Hewlett Packard Australi...

Page 85: ...Legal and Regulatory Information ASSISTANCE Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 86: ...Index Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 87: ...V 3 13 add service documentation option 0BW 3 13 ALC CTRL 3 27 assembly level service documentation for 1 3 3 13 At a Glance v C cable HP MSIB 3 4 SMA 3 4 SMB 3 4 cables not included 3 4 calibration documentation for 3 13 CLIM 1 3 3 3 column address 1 8 Component Level Information Package 3 13 component level service documentation for 1 3 Connectors rear panel 3 5 3 26 CURRENT indicator 2 9 Index ...

Page 88: ... checking the 1 13 to check the 2 8 ESD 3 9 extra user documentation option 0B2 3 13 F Flexible Cables 3 3 Flexible Coaxial Cables 3 7 functional veri cation 1 2 fuse mainframe 2 4 3 4 part number of 3 4 H hex ball driver 3 4 HP 70004A Display iv HP IB access to 1 8 HP MSIB legal addresses 1 7 HP MSIB address determining decimal 1 8 HP 70340A factory preset 1 7 HP 70341A factory preset 1 8 locatio...

Page 89: ...l Damage 2 2 MMS preparation of 1 4 O Option 0B2 3 3 0B2 1 3 0BV 1 3 3 3 0BW 3 3 0BW 1 3 option 0B2 extra user documentation 3 13 option 0BV add component level service documentation 3 13 option 0BW add assembly level service documentation 3 13 option 1E1 add output step attenuator 3 27 option 1E2 internal pulse modulation generator 3 28 option 1E8 1 Hz frequency resolution 3 28 option 1E9 3 5 mm ...

Page 90: ...FFFFFFFFFFFFFFFFFFFFFFFFFFFFF REPORT ERRORS 2 8 row address 1 8 S Semi rigid Cables 3 3 3 6 serial number pre x iii su x iii service documentation option 0BV 3 13 service documentation option 0BW 3 13 service documentation set 3 13 shipment contents of 1 3 3 3 SMA Connectors 3 6 SMB Connectors 3 7 speci cations rear panel connectors 3 26 Speci cations HP 70340A 41A 3 13 static safe accessories 3 1...

Page 91: ...Panel Connections 1 11 tools installation 1 2 part numbers of 3 4 To Prepare the MMS for HP 70341A Installation 1 4 torque wrench rear panel connections 1 11 To Unpack the HP 70341A 1 2 U user documentation set 3 13 W warranty options 3 12 Index 6 Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com ...

Page 92: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...

Reviews: