Agilent Technologies
54600-Series Oscilloscopes

Data Sheet

Multiple configurations to 
meet your needs

If you work with both analog 
and digital components, Agilent
Technologies 54600-Series 
oscilloscopes can help you easily
see more of what's going on in
your designs. The unique 2 +
16-channel mixed signal oscillo-
scope (MSO) models and the tra-
ditional 2- and 4-channel models
are optimized with just the capa-
bilities you need for verifying and
debugging designs that include
A/Ds, D/As, DSPs, and embedded
8- or 16-bit microcontrollers.
These scopes give you the tools
you need to solve your mixed 
analog and digital engineering
challenges more easily.

Ideal for mixed analog and 
digital analysis

Ideal for analyzing designs with
both analog and digital com-
ponents, the 54600-Series scopes
combine three critical features: 

• Up to 8 MB of MegaZoom deep

memory come standard so you
can capture long, non-repeat-
ing signals, maintain high sam-
ple rate, and quickly zoom in
on areas of interest

• A revolutionary ultra-respon-

sive, high-definition display
that lets you see more signal
detail than ever before

• Flexible triggering that lets you 

easily isolate and analyze the
complex signals and fault 
conditions common in mixed
analog and digital designs. 
I

2

C, CAN, LIN, USB, and SPI 

triggering come standard.
N2758A CAN trigger module
option is also available.

This combination of capabilities
is tailored to give you the meas-
urement power you need to get
your mixed analog and digital job
done faster.

At Agilent Technologies, we focus
on developing products that help
you do your job better. That’s 
why 54600-Series scopes are 
optimized for your needs. Choose
the one that’s right for your 
application and your budget.

Easily see what's happening in your
mixed analog and digital designs

• 60 to 500 MHz, up to 2 GSa/s

• Unique 2 + 16-channel MSO 

and 2- or 4-channel models

• 4 MB to 8 MB MegaZoom deep

memory standard

• Patented high-definition 

display system

• Flexible triggering including CAN,

I

2

C, LIN, SPI, and USB 

•  Deep memory transfer over 

the interface bus

Summary of Contents for 54600-Series

Page 1: ... maintain high sam ple rate and quickly zoom in on areas of interest A revolutionary ultra respon sive high definition display that lets you see more signal detail than ever before Flexible triggering that lets you easily isolate and analyze the complex signals and fault conditions common in mixed analog and digital designs I2C CAN LIN USB and SPI triggering come standard N2758A CAN trigger module...

Page 2: ...nels 54621A 60 MHz 200 MSa s 4 MB 2 54621D 60 MHz 200 MSa s 4 MB 2 16 54622A 100 MHz 200 MSa s 4 MB 2 54622D 100 MHz 200 MSa s 4 MB 2 16 54624A 100 MHz 200 MSa s 4 MB 4 54641A 350 MHz 2 GSa s 8 MB 2 54641D 350 MHz 2 GSa s 8 MB 2 16 54642A 500 MHz 2 GSa s 8 MB 2 54642D 500 MHz 2 GSa s 8 MB 2 16 Maximum sample rate and memory are interleaved deep memory is standard no options needed ...

Page 3: ... and monitor the high speed digital control signals and the slower analog signals in your design 4 channel scope model 54624A If your designs include heavy analog content the 100 MHz 54624A will give you the channel count and measurement power you need including MegaZoom deep memory high definition display and flexible triggering Whether you re testing designs with four inputs such as anti lock br...

Page 4: ...with MegaZoom deep memory as you can have both with a single measurement Deep memory means that the sample rate stays high even when captur ing long time periods The 54600 Series scopes are the only deep memory scopes that respond instantly to your control inputs with a fast responsive display Compare them to other scopes in this price range only the 54600 Series provides deep memory at an afforda...

Page 5: ...an download data or insert a snapshot of an oscilloscope screen directly into your Microsoft Excel spreadsheets or Word documents or save the image as a bitmap file Once the data is in an Excel spreadsheet you can leverage Excel s extensive analysis functions to create custom graphs and views For more information on IntuiLink please see the IntuiLink datasheet with Agilent publication number 5980 ...

Page 6: ...s peak detect on the 54640 Series and 5 ns peak detect on the 54620 Series means you won t have to worry about missing narrow glitches Autoscale lets you quickly dis play any active signals auto matically setting the vertical horizontal and trigger controls for the best display Printer connectivity is easy for HP Deskjets Laserjets Epson or integrated thermal printer option with the stan dard para...

Page 7: ... CAN frames meeting the user specification The CAN trigger module is ideal for analyzing all traffic on the broadcast network Quickly find frames that meet the specifica tions you select with an isolating capability similar to pattern triggering across multiple channels in the parallel domain Synchronize to the particular frame then examine the system behavior of interest For more comprehensive in...

Page 8: ...y to synchronize CAN LIN and USB frames Don t waste time finding the start of the complex frames let Agilent do it for you CAN triggering synchronizes to the start of a CAN frame on any CAN high or CAN low signal Trigger on LIN local interconnect network sync break at the begin ning of a message frame Figure 5 Easily synchronize to a USB packet Figure 6 Make your automotive and industrial testing ...

Page 9: ...copes to be inade Figure 7 Trigger on data patterns within a SPI frame Figure 8 Trigger on address and or data patterns within an I2C frame The full range of I2C triggering includes start or stop condition missing acknowledge restart EEPROM data read address and or data frame or 10 bit write SPI triggering allows for trigger on user definable framing and user definable number of bits per frame as ...

Page 10: ... have to choose capture all of your data at once Revolutionary high definition display reveals subtle details that most scopes won t show you Standard RS 232 and parallel ports provide PC and printer connectivity Free IntuiLink PC software makes transfer of waveform data to PC fast and easy Intensity knob allows you to adjust the contrast on screen Built in floppy drive makes it easy to save your ...

Page 11: ...omated file names Standard Serial Triggering includes CAN I2C LIN SPI and USB Built in help is available in 11 languages Simply press and hold the front panel key of interest for a few seconds and a help screen pops up to explain its function Maximum sample rate and resolution on every measure ment The scope automatically adjusts memory depth as you use it so you get maximum sample rate and resolu...

Page 12: ...z 150 MHz 250 MHz 50 MHz Probe Risetime Calculated 17 5 ns 700 ps 2 33 ns 1 4 ns 7 ns Attenuation Ratio 1 1 10 1 10 1 100 1 1000 1 Input Resistance 1 MΩ 2 2 MΩ 10 MΩ 66 7 MΩ 100 MΩ when terminated into 1 MΩ Input Capacitance Approx 70 pF Approx 12 pF Approx 15 pF Approx 3 pF Approx 1 pF Maximum Input 400 Vpk CAT I 500 Vpk CAT I 500 Vpk CAT I 4000 Vpk 15 kV dc 10 kVrms dc peak ac mains isolated mai...

Page 13: ...D only Max Sample Rate 54621D 54622D 400 MSa s interleaved 200 MSa s each channel 54641D 54642D 1 GSa s Max Memory Depth 54621D 54622D 8 MB interleaved 4 MB ea channel 54641D 54642D 4 MB Vertical Resolution 1 bit Glitch Detection 5 ns min pulse width Vertical System Analog Channels Analog Channels 54621A D 54622A D 54641A D 54642A D Ch 1 and 2 simultaneous acquisition 54624A Ch 1 2 3 and 4 simulta...

Page 14: ...obe sense Tek compatible ESD Tolerance 2 kV Noise Peak to Peak 54621A D 54622A D 54624A 2 full scale or 1 mV whichever is greater 54641A D 54642A D 3 full scale or 3 mV whichever is greater Common Mode Rejection Ratio 20 dB 50 MHz DC Vertical Gain Accuracy 1 2 2 0 full scale DC Vertical Offset Accuracy 54621A D 54622A D 54624A 200 mV div 0 1 div 1 0 mV 0 5 offset value 200 mV div 0 1 div 1 0 mV 1 ...

Page 15: ...nier 1 2 5 increments when off 25 minor increments between major settings when on Reference Positions Left Center Right Delay Range 54621A D 54622A D 54624A Pre trigger negative delay Greater of 1 screen width or 10 ms Post trigger positive delay 500 seconds 54641A D 54642A D Pre trigger negative delay Greater of 1 screen width or 1 ms Post trigger positive delay 500 seconds Analog Delta t Accurac...

Page 16: ...any source Pattern Trigger on a pattern of high low and don t care levels and or a rising or falling edge established across any of the sources The analog channel s high or low level is defined by that channel s trigger level Pulse Width Trigger when a positive or negative going pulse is less than greater than or within a specified range on any of the source channels Minimum pulse width setting 5n...

Page 17: ...54624A Greater of 0 35 div or 2 5 mV 54641A D 54642A D 10mV div greater of 1 div or 5mV 10mV div 0 6 div Coupling AC 3 5 Hz on 54621A D 54622A D 54624A 10 Hz on 54641A D 54642A D DC noise reject HF reject and LF reject 50 kHz Digital D15 D0 Channel Triggering 54621D 54622D 54641D and 54642D Threshold Range used defined 8 0 V in 10 mV increments Threshold Accuracy 100 mV 3 of threshold setting Pred...

Page 18: ...l time X at Max Time at max volts X at Min Time at min volts Delay and Phase on analog channels only Counter Built in 5 digit frequency counter on any channel Counts up to 125 MHz Threshold Definition Variable by percent and absolute value 10 50 90 default for time measurements Cursors Manually or automatically placed readout of Horizontal X X 1 X and Vertical Y Y Additionally digital or analog ch...

Page 19: ...B Interface Fully programmable with IEEE488 2 compliance Module N2757A Typical GPIB throughput of 20 measurements or twenty 2000 point records per second Optional Printer Kit The N2727A is a thermal printer kit includingprinter power parallel cable power cable and paper General Characteristics Physical Size 32 26 cm wide x 17 27 cm high x 31 75 cm deep without handle Weight 6 35 kgs 14 lbs on 5462...

Page 20: ...ent class B1 and MIL PRF 28800F operating 30 g 1 2 sine 11 ms duration 3 shocks axis along major axis Total of 18 shocks Pollution Degree2 Normally only dry non conductive pollution occurs Occasionally a temporary conductivity caused by condensation must be expected Indoor Use Only This instrument is rated for indoor use only Other Installation Categories CAT I Mains isolated CAT II Line voltage i...

Page 21: ...500 MHz Mixed Signal Oscilloscope Accessories Included 54621A 54621D 54622A 54622D 54624A 54641A 54641D 54642A 54642D User s Guide localized Service Manual Programmer s Manual Power cord 10073C 10 1 divider 0 0 0 0 0 2 2 2 2 probes with readout 10074C 10 1 divider 2 2 2 2 4 0 0 0 0 probes with readout 16 2 x 8 input logic input probe assembly Accessories pouch and front panel cover IntuiLink softw...

Page 22: ...ars of return to Agilent inclusive calibration service R 50C 013 5 5 years of return to Agilent inclusive plus calibration service R 51B 001 3C 1 year return to Agilent warranty extended to 3 years R 51B 001 5C 1 year return to Agilent warranty extended to 5 years Accessories Description 1183A Testmobile scope cart 1185A Carrying case 1186A Rackmount kit same as option 1CM N2726A Accessory pouch f...

Page 23: ...robe ac dc N2775A Power supply for N2774A High Voltage Probes Description 10076A 100 1 4 kV 250 MHz probe with ID N2771A 1000 1 15 kV 50 MHz high voltage probe Logic Probes Description 10085 68701 16 16 logic cable and terminator for use with 54621D 622D 641D 642D 54620 68701 16 2 x 8 logic input probe assembly shipped standard with 54621D 622D 641D 642D Active probes Description 1144A 800 MHz act...

Page 24: ...ssistance for the use of specified capabilities at no extra cost upon request Many self help tools are available Your Advantage Your Advantage means that Agilent offers a wide range of additional expert test and measurement services which you can purchase according to your unique technical and business needs Solve problems efficiently and gain a competitive edge by contracting with us for calibrat...

Reviews: