BU-0101704 R3
Figure 26.
Install the Tandem Gearboxes
3. Secure the lower gearbox shaft (5) to the flighting coupler (6) with a 1/4” x 1-1/2” key (not shown) and
spring pin (7) (see
Figure 27.
Attach Flighting to Lower Gearbox
4. Fasten the gearbox mount bracket (1) to the center sump divider wall using three 1/2” x 1-1/2” bolts (2), flat
washers (3), and nylon locknuts (8) (see
Note
For the bottom mount hole, there are two sets of micro-jointed holes, depending on the size of tube
unload. For an 8” unload, punch out the lowest hole. For a 10” unload, punch out the upper offset
hole.