100
7713397 R2
5. Specifications
5.1. Standard Model Specifications
Refer to the following table for specifications on standard NECO dryers. They are listed by model number as
shown on the rating plate located on the front of the main control.
If the model number of your particular dryer is not shown below, contact your dealer.
Table 13.
Standard Model Specifications
Model
Number
Number
of Tiers
Holding Capacity
Number of
Burners and
Blowers
TOTAL Blower Output
(Max)
TOTAL Burner Output
(Max)
Bushels
(See Notes)
Metric
Tonnes
cubic ft/min
cubic m/min
MMBTU /hr
kWH
D1660
4
579
15
1
21,500
609
4.9
1436
D1670
5
674
17
1
23,500
665
6.1
1788
D1680
6
770
19
1
27,500
778
5.8
1702
D1690
7
866
22
1
32,000
905
6.3
1846
D16106
8
962
24
2
36,600
1,035
9.8
2872
D16120
10
1,155
29
2
47,000
1,330
11.6
3404
D16140
12
1,347
34
2
55,000
1,556
11.2
3272
D16160
14
1,539
39
3
65,300
1,847
16.5
4840
D16180
16
1,731
44
3
78,500
2,221
17.2
5041
D24108
6
1,155
29
2
41,200
1,165
9.8
2872
D24150
8
1,443
36
2
55,000
1,556
11.6
3404
D24180
10
1,732
44
2
62,000
1,754
16.0
4689
D24210
12
2,020
51
3
82,500
2,334
17.4
5106
D24240
14
2,309
58
3
89,500
2,532
21.8
6391
D24260
16
2,597
66
4
110,000
3,113
23.2
6809
D24330
20
3,174
80
5
137,500
3,891
29.0
8511
D24380
24
3,750
95
6
165,000
4,669
34.8
10213
D32260
12
2,693
68
3
108,000
3,056
18
5,275
D32340
16
3,463
88
4
144,000
4,075
27
7,913
D32440
20
4,232
107
5
182,000
5,150
45
13,188
D32500
24
5,001
127
6
216,000
6,112
54
15,826
Note
1. Drying capacities represent NECO’s best estimate of attainable wet bushel capacities based on a
combination of actual field results and computer analysis.
2. Capacities will vary depending on outside temperature, humidity, initial grain temperature, crop maturity
and variety, cleanliness of the grain, test weight, operating temperature, drying vs. cooling zones, etc.
3. Hot grain discharged from the dryer will dry an additional 1.5% – 2% when properly cooled.
4. Average burner output MMBTU/hr is based on 155° F temperature rise. Ambient of 55° F and dryer
operating temperature of 210° F.
5. Holding capacity values represent corn at 15.5% moisture content (56 lb/bushel).
CONTINUOUS-FLOW GRAIN DRYER – COMMANDER CONTROL