AGFEO AS 40P Installation Manual Download Page 8

8

Switchable S0 connection S0 0/2(internal or external S0 connection) ¢¢¢¢¢¢

External S0 connection S0 0/2

You may connect the external SO
Connection to a System Access (PTP) or
Standard Access (PTPM) line. Please refer
to External SO Connection (RJ45 Socket).
Use the enclosed ISDN Cable and connect
the four wires to the SO connection block
of the module.
-  Push the wire all the way into the

connection block without pressing the
release catch.

-  Connector: a1 -green

b1 -brown
a2 -yellow
b2 -white

-  To disconnect a wire, press the release

catch with a small screwdriver while at
the same time pulling out the conductor.

-  Guide the cable through the cable comb.

Termination Resistors for the external SO
Connection
System Access (PTP) 

–Both switches

S1301/cd for the 100 Ohm terminators
must be closed ("as-delivered" setting).

Standard Access (PTMP)

  - Both switches

S1301/cd for the 100 Ohm terminators
must be:

-  

closed or set to on

 if the connection is

made directly onto the NTTP or on the
last socket which has no 100 Ohm
Termination Resistors fitted.

-  

open or set to off

 if the last socket has

the 100 Ohm Termination Resistors
installed or if the telephone system is
not the last ISDN device on a PTMP line.

Plug the ISDN Plug into the ISDN
connection after completion of all
installation work.

Both switches S1301/cd are on the compo-

nent side of the module.

Do not insert the Western plug of the con-
necting cable into your ISDN connection
socket until all installation work has been
completed.

Internal S0 connection S0 0/2

You can connect up to 8 ISDN devices like
on a PTMP connection on the internal SO
Bus of the System.
ISDN Apparatus:
Digital AGFEO System Phones (max 2
digital phones per SO Bus)
-ISDN -Telephones
-ISDN -PC-Cards
-ISDN –Fax machines
Up to four ISDN devices without additional
power may be connected. For example: 4
ISDN Telephones or 2 Digital System
Phones plus 2 ISDN Telephones.
Connections of further ISDN devices will
need their own power source.
ISDN Apparatus must use the DSS1
protocol.
You will need the following material to
install an internal SO Bus.
Telephone wire CW1308 (minimum 2 pair)
or CAT5 Cable
RJ45 Sockets max. 12 per Bus
2 Termination Resistors, 100 Ohm  0.25 W
Maximum SO Bus length will be 130 m.
(Telephone System to last RJ45 Socket)

Termination Resistors for the Internal SO
Connection

The internal SO Bus must be terminated.
Install two 100 Ohm Resistors in the last
RJ45 Socket
(See Diagram). Both witches S1301/cdmust
be closed.

Summary of Contents for AS 40P

Page 1: ...Installation manual Profi Line AS 40 AS 40 P ISDN PABX System...

Page 2: ...ring a thunderstorm Lay subscriber lines in such a way that no one can step on them or stumble over them Prevent the ingress of liquid into the telephone system as otherwise short circuits may occur N...

Page 3: ...here are no explosion hazards It must not be installed in the proximity of air conditioning systems radiators devices that produce inadmissible inter ference radiation in locations that are subject to...

Page 4: ...s and pull down the telephone sys tem on the wall until it moves no further Firmly screw down the telephone system with the third screw in the bottom dowel Figure 1 telephone system with detached cove...

Page 5: ...latching lug of the module latches into the lock Pull the adhesive label showing the module s connections off the information sheet included with the Installing and replacing modules module packaging...

Page 6: ...ystem Fixed slot X 0 outside right The con nection module must not be plugged on to any other slot as otherwise the connector will be damaged Interfaces 1 External S0 interface S0 0 1 ISDN basic acces...

Page 7: ...one ISDN telephone system to an ISDN point to point connec tion You cannot connect any further ISDN terminals Using the ISDN connecting cable connect the ISDN telephone system directly to the NTBA or...

Page 8: ...telephone system is not the last ISDN device on a PTMP line Plug the ISDN Plug into the ISDN connection after completion of all installation work Both switches S1301 cd are on the compo nent side of t...

Page 9: ...nternal S0 connection 100 Wire pair 1 a1 b1 Wire pair 2 a2 b2 b1 b2 a1 a2 S0 internal 100 Max distance 130 m S0 bus 1 UAE 2 3 4 5 6 7 8 1 UAE 2 3 4 5 6 7 8 1 UAE 2 3 4 5 6 7 8 1 UAE 2 3 4 5 6 7 8 b1 b...

Page 10: ...ario ports You must not connect the Da and Db wires System telephone Connect system telephones by means of four wires to the Vario ports by connecting them to the La and Lb wires speech wires and the...

Page 11: ...cting subscriber lines Mark the cables with the included mark ing system Strip 11 mm off the wires Push the individual wires into the termi nal until they move no further without pressing the terminal...

Page 12: ...e S0 Module 420 The S0 module features the following in terfaces 1 External S0 interface S0 X 1 ISDN basic access as a point to multipoint or point to point connection 1 Switchable internal external S...

Page 13: ...SDN sockets IAE UAE may belong to this S0 bus Be sides the ISDN telephone system you can connect up to 7 further ISDN terminals to the S0 bus Terminators for the external S0 access S0 0 1 For the poin...

Page 14: ...ephone system is not the last ISDN device on a PTMP line Plug the ISDN Plug into the ISDN connection after completion of all installation work Both switches S4102 ab are on the compo nent side of the...

Page 15: ...nternal S0 connection 100 Wire pair 1 a1 b1 Wire pair 2 a2 b2 b1 b2 a1 a2 S0 internal 100 Max distance 130 m S0 bus 1 UAE 2 3 4 5 6 7 8 1 UAE 2 3 4 5 6 7 8 1 UAE 2 3 4 5 6 7 8 1 UAE 2 3 4 5 6 7 8 b1 b...

Page 16: ...nternal external S0 interfaces external ISDN basic access as a point to multipoint or point to point connection internal point to multipoint connection Slots X 1 to 4 freely optional Switching to an i...

Page 17: ...stermann 230 V TO NF NF TS KT KT door opener bell transformer for door opener The TFE Module 402 door hands free unit The TFE module 402 features two interfaces conforming to the 4 wire TFE specificat...

Page 18: ...ener The TFE Module 403 door hands free unit The TFE module 403 features an interface TFE 1 that conforms to the Telekom 2 wire TFE CE interface specification for connecting DoorLine T01 to T04 door h...

Page 19: ...ushbuttons Connections Figure 12 Connect the DoorLine T01 to T04 door hands free units to the contacts NF and NF Controlling the door opener Maximum contact load 30 V DC 1 A You can only actuate the d...

Page 20: ...u must plug the TFE modules in the following arrangement Slot from left to right TFE module 402 relay 1 to 4 TFE module 402 relay 5 to 8 TFE module 402 or 403 TFE TFE Module 403 Instead of the door ha...

Page 21: ...r cassette recorder or stereo system with a 3 5 mm jack plug to the jack socket X external MoH on the underside of the telephone system Figure 1 Set the volume of external music on hold on the audio d...

Page 22: ...onnection you need a cable that corresponds to the pin as signments given below maximum length 3 m Your printer must be set as follows 9600 baud 8 bits 1 stop bit no parity To print out connection rec...

Page 23: ...as far as the stop Fig 16 Locking the cover Figure 15 Figure 16 Pull out the black bolt slightly to the side using a narrow srewdriver blade about 2 mm wide until you can grip the bolt Fig 17 and 18 h...

Page 24: ...on a PC you can set the telephone system s functions to suit your needs Remote setting by your specialist dealer is possible Commissioning You have installed the telephone system Now only a few operat...

Page 25: ...access 1 switchable internal external S0 access S0 module 440 4 switchable internal external S0 access TFE module 402 2 interfaces for the connection of 2 door hands free 4 wire units to FTZ 123 D 12...

Page 26: ...32C Range level 3 m 5 V Connection 9 pole D sub socket External music on hold e g via a variable headphone output of a cassette recorder or CD player Input impedance 100 kOhm asymmetrical Input voltag...

Page 27: ...This applies to electronic mechanical optical chemical and other media Trademarks and company names used in this documentation are subject to the rights of the respectively affected compa nies Technic...

Page 28: ...GmbH Co KG Gaswerkstr 8 D 33647 Bielefeld Internet http www agfeo de Ident No 1529435 Subject to change without notice No liability can be accepted for errors contained in this document Printed in Ger...

Reviews: