Telekommunikation
AS 40 - Modul
Installation of the module
Safty notes ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢
!
Before unlocking the cover, remove the 230 V mains plug
from the telephone system.
Opening the housing ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢
Unlocking the cover
- Pull out the black bolt slightly to the side
using a narrow srewdriver blade (about 2
mm wide) until you can grip the bolt
(Fig.1 and 2).
- Hold the bolt and pull it right out turning
it slightly (Fig. 2 and 3).
You can use the bolt as a module extrac-
tor when exchanging a module.
Removing the cover
- Grip the underside behind the finned
cover that covers the telephone system’s
connection panel.
- Pull the edge of the cover down slightly to
unlatch it. Detach the cover towards you.
Bolt
Unlocking the cover
Fig. 1
Fig. 3
Fig. 2
Removing the module from the packaging - Safety measure ¢¢¢¢¢¢¢¢¢¢¢¢¢¢¢
Before removing the module from the
packaging and before inserting the
module in the AS 40, touch the metal
shield of the PC/printer socket on the
bottom of the AS 40 briefly with your
finger. This discharges any possible
electrostatic charge and protects
electrostatically sensitive components of
the AS 40 and the module.
1