AGFA Drystar 4500 Plug & Play Installation Manual Download Page 2

2/18

2805F EN 20050128

The device must only be operated according to its specifications and its intended use. Any operation not 
corresponding to the specifications or intended use may result in hazards, which in turn may lead to serious 
injuries or fatal accidents (for example electric shock). AGFA positively will not assume any liability in these 
cases. 

The device must only be installed and put into operation under the specified conditions.
For more information about safety, security and use, refer to the Drystar 4500 Reference and User manual.

For more information on Agfa products and Agfa HealthCare products, please visit www.agfa.com, your Point of Knowledge.

© Agfa-Gevaert N.V. 2005.

No parts of this document may be reproduced, copied, adapted or transmitted in any form or by any means without the written permission of
Agfa-Gevaert N.V.

Agfa-Gevaert N.V. makes no warranties or representation, expressed or implied, with respect to the accuracy, completeness or usefulness of the
information contained in this document and specifically disclaims warranties of suitability for any particular purpose. Agfa-Gevaert N.V. shall
under no circumstances be liable for any damage arising from the use or inability to use any information, apparatus, method or process disclosed
in this document.

Agfa-Gevaert N.V. reserves the right to make changes to this document without prior notice.

Agfa-Gevaert N.V., Septestraat 27, B-2640 Mortsel, Belgium.

Drystar 4500 is a trademark of Agfa-Gevaert N.V., Belgium.

Agfa and the Agfa-Rhombus are trademarks of Agfa-Gevaert AG, Germany.

Summary of Contents for Drystar 4500 Plug & Play

Page 1: ...500 Reference manual Agfa Medical Agfa Medical DECLARATION OF CONFORMITY XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX ...

Page 2: ... N V 2005 No parts of this document may be reproduced copied adapted or transmitted in any form or by any means without the written permission of Agfa Gevaert N V Agfa Gevaert N V makes no warranties or representation expressed or implied with respect to the accuracy completeness or usefulness of the information contained in this document and specifically disclaims warranties of suitability for an...

Page 3: ...XXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX Two film packs Set of manuals Set of documents Phillips screwdriver Set of cables 1 Contents of the packages Drystar 4500 2 Required tools Included Not included Wire cutter Philips screwdriver 6 mm Allen key Standard screwdr...

Page 4: ... 20050128 2 Remove the packing materials 1 Remove the cardboard box 3 Remove the plastic bag Accessories FRONTSIDE 2 Remove the foam blocks 4 Remove the front panel protection 5 Create a descending slope Unpacking A ...

Page 5: ...on a van continue unpacking as described and refer to the illustration when securing the printer to the van floor 2 Remove eight screws and two fixation bars MOBILE SEISMIC INSTALLATION ONLY reuse the fixation bars and screws to secure the printer at its final location 4 Pull the printer down the slope and relock the wheel brakes 1 2 3 1 2 3 4 1 1 2 2 1 2 A Unpacking ...

Page 6: ...or a complete list of accessories Drystar 4500 User manual DECLARATION OF CONFORMITY XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX XXXXXX XXXX XXXXXX Drystar 4500 Reference manual Agfa Medical Agfa Medical Refer to the Packing slip for a...

Page 7: ...en 20 and 75 non condensing 600 mm 24 600 mm 24 600 mm 24 600 mm 24 600 mm 24 100 mm 4 Space required for normal use Space required for servicing and installation 2 Power requirements 3 Network requirements The AC outlet must have either of following specifications 100 120 V 60 Hz 16 15 A or 200 240 V 50 Hz 16 15 A Ethernet connectors RJ45 twisted pair for 10 100Base TX Serial RS232 connection Net...

Page 8: ...protection blocks 1 Open the upper input tray and the top cover 3 Close the upper tray and the top cover 5 Remove the protection foam 1 2 3 1 2 2 Remove the protection foam 4 Open the lower input tray 6 Close the lower input tray 2 1 Installation B ...

Page 9: ...rotection straps 1 Open both input trays and the top cover 3 Cut the two upper red straps 5 Open the film input assembly 1 2 3 4 2 Take wire cutter 4 Cut the two lower red straps 6 Cut the red strap and close the input trays and the top cover B Installation ...

Page 10: ...en the front cover 3 Take standard screwdriver 5 Push two pins upwards and remove the right side cover 1 1 2 2 Remove the two adhesive straps and close the front cover 4 Unlock the quarter turn fastener 6 Remove the left side cover 1 2 2 3 Installation B ...

Page 11: ...the pulley 2 4 Slowly turn the pulley by hand to assist the belt 1 2 2 On the right loosen and refasten the red blocking plate Turn the pulley only slowly to assist the mounting of the belt If the printer will not be used for a prolonged time at least four weeks it is recommended to remove the belt during this period B Installation ...

Page 12: ...right side cover on the bottom positioning pins 4 Reinstall the left side cover 1 2 2 2 1 3 Lift the top pins into their positioning holes 5 Refasten both quarter turn fasteners and close the top cover When reinstalling the side covers take into account the positioning pins at the bottom and the top 2 2 1 Installation B ...

Page 13: ...the cables 2 Locate the mains connector 4 Mount the strain relief 6 Move the printer to its final destination and lock the wheel 1 Select the power cable 3 Connect the power cable 5 Locate the network connector and connect the network cable B Installation ...

Page 14: ... retainers The films delivered with the printer are intended for test purposes only Load 8x10 test films in the upper tray and 10x12 test films in the lower tray 2890B Check the icons on the film bag before loading films 1 Open the upper input tray 3 Place the film pack in the tray 5 Place the correct film sticker This side down Loading films C ...

Page 15: ...ace the film pack in the tray with perforated protective sheet down 5 Place the correct film sticker This side down 6 Open the film pack 4 Close the lower input tray verify that film is under the retainers 6 Note for film size 8x10 lift the partition clips before loading the film 2892B Check the icons on the film bag before loading films C Loading films ...

Page 16: ...18 2805F EN 20050128 14 Startup Drystar 4500 1 Press the POWER button 3 Press the lower left corner to open the keypad cover POWER POWER STOP 2 Wait until the READY status is displayed POWER STOP D Startup ...

Page 17: ...rator key 2 Press the Down key six times 3 Press the Confirm key 4 Press the Down key once to select Printer install wizard 5 Press the Confirm key 6 Follow the instructions 1 x 6 x 1 x 1 x 1 x 2 Select and initiate printer calibration Ask your network manager the following information Printer IP address Netmask Router IP address Called AE_Title 1 Press the Key operator key 2 Press the Down key fi...

Page 18: ...18 18 2805F EN 20050128 ...