background image

9 Norfolk Court, Coburg North Victoria 3058

Tel: (03) 9355 7100
Fax: (03) 9355 7166
Email: [email protected]
Web: www.agradefinish.com.au

AGF Professional 1500

INSTALLATION INSTRUCTIONS

 

450mm 

850mm 

1500mm 

 

595mm – 1000mm 

300mm 

600mm 

Summary of Contents for Professional 1500

Page 1: ...t Coburg North Victoria 3058 Tel 03 9355 7100 Fax 03 9355 7166 Email sales agradefinish com au Web www agradefinish com au AGF Professional 1500 INSTALLATION INSTRUCTIONS 450mm 850mm 1500mm 595mm 1000...

Page 2: ...t as it contains important information Please make sure you follow these installation instruction as they contain vital safety information Be sure to keep your proof of purchase as this will be needed...

Page 3: ...rning the method and frequency of cleaning The appliance is supplied with an approved power cable If the supply cord of this equipment is damaged it must only be replaced by the manufacturer its servi...

Page 4: ...ehood Refer figure 1 Step 3 Mark out the height that you rangehood is to be installed at Refer figure 2 Step 4 Hold rangehood up to the marks step 2 and 3 and mark the mounting points Refer figure 3 S...

Page 5: ...the ducting is to pass through the roof Make sure that when marking out the location of the ducting it is next to a beam for support With the location of the ducting confirmed cut the hole out in the...

Page 6: ...h some PVC duct tape Refer figure 9 Pass the flexible duct through the hole in the ceiling and connect to the 3 way joiner Secure with PVC duct tape Connect the flexible to the solid ducting and the 3...

Page 7: ...ngehood to male plug of double adaptor Refer figure 14 Step 17 Connect both of the fans to the double adaptor Step 18 Installing the flue cover With both flue pieces connected to each other smaller pi...

Page 8: ...the handles and slide the filter to the back of the unit Once you have the filter at the back of the unit this will enable the filter to release from the rangehood To Re install the filters slide the...

Page 9: ...ectrical switches We recommend the use of stainless steel cleaning wipes When cleaning your roof cover roof mount fan with plastic if you are going to use chemicals Globe Removal Ensure unit is turned...

Page 10: ...and holder to lamp lead 6 Insert back into housing and turn in clockwise direction to lock into place 7 Technical Support For all technical support please contact A Grade Finish Canopies on 03 9355 7...

Page 11: ...e defect claimed is due to faulty or defective parts or workmanship This warranty does not cover a light globes batteries filters or similar perishable parts b parts and Appliances not supplied by A G...

Page 12: ......