![AGCO AP Cumberland VariFlame VF-16-ENG Owner'S Manual Download Page 15](http://html1.mh-extra.com/html/agco/ap-cumberland-variflame-vf-16-eng/ap-cumberland-variflame-vf-16-eng_owners-manual_2866440015.webp)
2
Specifications
Topics Covered in this Chapter
VariFlame vapor propane specifications
VariFlame natural gas specifications
VariFlame vapor propane specifications
Maximum input
250,000 (BTUH)
Minimum input
50,000 (BTUH)
Ventilation air required to support combustion
1,050 (CFM)
Inlet gas supply pressure maximum
13.5 in. W.C.
Inlet gas supply pressure minimum
12.0 in. W.C.
Burner manifold pressure maximum
10.0 in. W.C.
Burner manifold pressure minimum
0.4 in. W.C.
Fuel consumption per hour maximum
11.58 lbs.
Fuel consumption per hour minimum
2.32 lbs.
Motor characteristics
1/3 H.P. 1100 RPM
Electrical supply (Volts/Hz/Phase)
115/60/1
Amp draw (Starting)
9.5
Amp draw (Continuous)
4.5
Dimensions (Inches) L x W x H
30.3 x 18.6 x 27.5
Net weight
98 lbs.
Shipping weight
112 lbs.
Minimum combustion distance
Top
1 ft. (0.3 m)
Sides
1 ft. (0.3 m)
Back
1 ft. (0.3 m)
Blower outlet
6 ft. (1.83 m)
Pneg-2092
VariFlame Heater with Edge Connect
15