Page
26
of
34
Touch control unit and thermocouples:
The TCU is attached to the main chassis by 4 screws, remove the screws to either exchange or gain
access to the rear of the panel, REMEMBER to support the TCU when doing this.
The thermocouples and the communications cable are all connected to the rear of the TCU.
The thermocouples are connected to the TCU in a certain order, it is important when either
replacing the TCU or a thermocouple, that the thermocouples are replaced in their correct position.
The abbreviations of the cooking zones are imprinted on the back of the TCU
BO (Baking oven),HS (Hot Spot / Boiling plate), SS (Simmer spot), SO (Simmer oven), RO (Roast oven).
The thermocouples are routed into their zones via conduits that run through the cooker and they
are held in place in a bracket in their respective zone. When a thermocouple is replaced the rubber
bungs must be put back in position to seal the conduit (see picture below).
Thermocouples entering conduits.
Roast oven thermocouple in bracket
Summary of Contents for RANGEMASTER eR7
Page 29: ...Page 29 of 34 Wiring schematic North America...
Page 30: ...Page 30 of 34 AGA Hotcupboard DESN 517488...
Page 31: ...Page 31 of 34...
Page 32: ...Page 32 of 34...
Page 33: ...Page 33 of 34...