AGA ML15CL Installation, Operation And Maintenance Instructions Download Page 4

6

INSTALLING THE DRAIN PLUMBING

Access

panel

Drain pipe, (not 

provided)

Drain tubing, cut 

to length and in-

stall in the drain

CL

CL

14

7

8

"

(37.8 cm)

11

16

"

(17mm)

1

1

4

"

(3.2 cm)

4

17

32

"

(11.5 cm)

21

1

2

"

(54.6 cm)

Drain Plumbing

Your ice machine requires drain plumbing. There are 2 

variations of ice machines in regards to the installation of 

the drain plumbing, without a drain pump (gravity drain), 

and with a drain pump.

Figure 9

Figure 8

Drain line coiled 

and secured to 

the back of the 

unit

Uncoil the drain line, route 

to an appropriate drain and 

cut to the required length

Electrical Shock Hazard

Reasonable care and safe methods should be prac-

ticed.  Do NOT work with energized electrical equip-

ment in a wet area.  Read and follow the installation 

instructions listed in this manual.

!

WARNING

!

CAUTION

Failure to use an adequate drainage system, will result in 

surrounding water damage and/or poor ice production.

Figure 7

!

CAUTION

Observe and follow all local building codes 

when installing this ice machine and drain 

lines.

Water 

supply 

inlet

Drain access in

bottom of unit

4

3

32

"

(10.4 cm)

Sanitary 

trap

2

1

4

"(5.7 cm)

5

1

8

" (13 cm)

Gravity Drain (no drain pump):

The ice machine is shipped with the drain line installed, 

coiled and secured to the back of the cabinet as shown 

in Figure 7. It can be uncoiled, routed to an appropriate 

drain and cut to length as required. Additionally there is the 

provision of drain routing through the cut-out in the bottom 

of the unit, (see the gray area in Figure 8). A drain can be 

installed in this gray area with the drain line cut to a short 

length and positioned into the drain as shown in Figure 9, 

or if the ice machine is to be built-in, the drain tube could be 

routed through a hole in the floor in this gray area to a drain 

below.

The gravity drain line must be routed no higher than 6" 

(15.2 cm) off the floor to assure proper drainage.

!

CAUTION

Summary of Contents for ML15CL

Page 1: ...glacons transparente Máquina de hielo claro ML15CL ML15CP EN Installation Operation and Maintenance Instructions FR Instructions d installation d utilisation et d entretien ES Instrucciones de instalación operación y mantenimiento ...

Page 2: ...front to back The overall height of your Marvel appliance may be adjusted higher by turning the leveling leg out and lower by turning the leveling leg in Cabinet height adjustment dimensions are shown in Table A To adjust the leveling legs place the appliance on a solid surface and protect the floor beneath the legs to avoid scratching the floor With the assistance of another person lean the appli...

Page 3: ... factory equipped with a power supply cord that has a three pronged grounded plug It must be plugged into a mating grounding type receptacle in accor dance with the National Electrical Code and applicable lo cal codes and ordinances see Figure 6 If the circuit does not have a grounding type receptacle it is the responsibility and obligation of the customer to provide the proper power supply The th...

Page 4: ...em will result in surrounding water damage and or poor ice production Figure 7 CAUTION Observe and follow all local building codes when installing this ice machine and drain lines Water supply inlet Drain access in bottom of unit 43 32 10 4 cm Sanitary trap 21 4 5 7 cm 51 8 13 cm Gravity Drain no drain pump The ice machine is shipped with the drain line installed coiled and secured to the back of ...

Page 5: ...8 inch I D tubing needs to be plumbed and connected to a sanitary sewer Refer to Figure 10 Figure 10 Drain pump vent tube Keep this open to assure air flows freely as water enters the pump reser voir Drain line coiled and secured to the back of the cabinet Uncoil route to an appropriate drain and cut to length Optional Drain Pump An optional drain pump is available if you have purchased an ice mac...

Page 6: ...er tubing to the top side of a cold water pipe to prevent the ice maker from plugging with sediment A shutoff valve is recommended on the water supply line to ease servicing the appliance NOTE A SELF PIERCING TYPE VALVE IS NOT RECOMMENDED as they are prone to clogging with sediment which will create pressure drop reducing the water supply to the unit Connect the copper tubing water supply to the w...

Page 7: ...el Kit This Filler Panel Kit will add 3 inches to the width of the ice machine for installation into an 18 inch wide opening Order one of the following part numbers for the color you require P N 42242831 White Filler Panel Kit P N 42242832 Black Filler Panel Kit P N 42242833 Stainless Steel Filler Panel Kit To order Call AGA Marvel customer service at 800 223 3900 177 8 45 4 cm Figure 12 ...