Fig.7
Fig.6
7
Secondary
Air Control
Supplementary
Wood Grate
Fig.8
Primary Air
Control
Fig.9
RECOMMENDED FUELS
This appliance has been tested using seasoned
wood logs and manufactured smokeless fuels
(MSF). These should be stored under cover and
kept as dry as possible prior to use.
Outputs
Parameter
Wood
MSF
Nominal Heat Output
kW
4.7
4.7
Mean Flue Gas Temperature
o
C
317
282
Flue Gas Mass Flow
g/s
5.5
6.2
Typical Refuelling Interval
h
1
1
Net Weight
kg
69
Gross Weight
kg
77
RE-FUELLING
When burning wood the requirement to riddle the
fire is much less. Do not riddle the fire with the spin-
wheel open but fully open the secondary air control
instead.
IT IS NECESSARY TO OPEN THE SPIN
WHEEL FULLY TO RE-ESTABLISH THE FLAME
TO PREVENT SMOKING. REMEMBER TO RESET
THE CONTROLS WHEN THE FLAMES ARE
BRIGHT.