SEE FIGS. 2 & 3.
CAUTION: BEFORE LIGHTING: ENSURE THAT THE GAS VALVE CONTROL KNOB (2) IS
SET IN THE OFF POSITION.
1.
Turn on gas supply to cooker and open gas cock
1
at the base of the gas valve.
2.
Turn the gas valve control knob
2
anti-clockwise to the position ( ) (see Fig. 3B). Press
down firmly and hold the knob in this position while depressing the piezo ignitor
3
several
times until the pilot has lit. This can be observed through the burner housing aperture.
3.
When the pilot has lit continue to hold the gas valve control knob down for approx. 30
seconds. If it goes out, wait
three minutes
and repeat the procedure holding for a little
longer.
4.
With the pilot flame established, rotate the gas valve control knob
2
anti-clockwise to its
low fire position (see Fig. 3C). Where upon the main burner will automatically light. Leave
in the low fire position for at least 30 minutes.
5.
After 30 minutes rotate the control knob further anti-clockwise to the mid-position of the
green band for normal running (see Fig. 3D).
NOTE: AFTER SEVERAL HOURS THE HEAT INDICATOR SHOULD BE ON OR ABOUT THE
BLACK LINE IN THE SILVER SECTION. IT MAY BE NECESSARY TO ADJUST THE
CONTROL KNOB SLIGHTLY IN THE GREEN BAND TO ACHIEVE THIS.
When the cooker is lit from cold, moisture may form on the enamel which should be wiped off to
prevent staining.
IF THE FLAME HAS EXTINGUISHED FOR WHATEVER REASON, WAIT THREE MINUTES
(MINIMUM) BEFORE RE-LIGHTING.
NOTE: IF THE PILOT EXTINGUISHES
For safety purposes a flue safety device
(6)
is fitted.
This will only operate in adverse flue conditions, it should be checked and if necessary
depressed. If this problem persists contact your local engineer to determine and rectify the
cause.
NOTE: REMEMBER TO NOTE THE SETTING OF THE GAS VALVE CONTROL KNOB 2
PRIOR TO EXTINGUISHING THE BURNER.
Turn the gas valve control knob clockwise to the off position (See Fig. 3A).
Frost Precautions
In the event of the cooker being switched
OFF
for long periods during very cold weather, the
advice of the local gas region or Aga Specialist should be obtained.
TO LIGHT THE BURNER
TO EXTINGUISH THE BURNER
5
Summary of Contents for GC 3
Page 6: ...BURNER CONTROLS 6 6 2 3 5 4 1 Fig 2 DESN 512341 DESN 512342 Fig 3 FIG A FIG B FIG C FIG D...
Page 9: ...9 REMOVAL OF OVEN SHELVES DESN 512405 DESN 512406 Fig 7 Fig 8...
Page 13: ...13...
Page 14: ...14...
Page 15: ...15...