AGA ATHOOD Instruction Manual Download Page 4

 

 

 

 

 

EN 

4

 

CHARACTERISTICS

 

Dimensions 

 

Components 

Ref.  Q.ty 

Product Components 

1 

1  Hood  Body,  complete  with:  Controls,  Light,  Blower, 

Filters

2 

1  Telescopic Chimney comprising: 

2.1 

1  Upper Section 

2.2 

1  Lower Section 

8a 

1  Right Air Outlet Grill 

8b 

1  Left Air Outlet Grill 

9 

1  Reducer Flange ø 150-120 mm 

10 

1  Adapting ring ø 120-125 mm  

15 

1  Air Outlet Connection 

Ref.  Q.ty 

Installation Components 

7.1 

2  Hood Body Fixing Brackets 

7.2.1 

2  Upper Chimney Section Fixing Brackets 

11 

8  Wall Plugs 

12a 

8  Screws 4.2 x 44,4 

12c 

6  Screws 2.9 x 9.5 

12d 

2  Screws M4 x 25 

 

Q.ty 

Documentation 

 

1  Instruction Manual 

 

 

17  

   

Styling rail

 

16  

   

Allen headed bolts

 

16

17

Summary of Contents for ATHOOD

Page 1: ...TRADITIONAL HOOD ATHOOD Instructions Manual...

Page 2: ...2 2 INDEX RECOMMENDATIONS AND SUGGESTIONS 3 CHARACTERISTICS 4 INSTALLATION 5 USE 8 MAINTENANCE 9 EN...

Page 3: ...der to prevent any risks USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has been designed Nev...

Page 4: ...Air Outlet Grill 8b 1 Left Air Outlet Grill 9 1 Reducer Flange 150 120 mm 10 1 Adapting ring 120 125 mm 15 1 Air Outlet Connection Ref Q ty Installation Components 7 1 2 Hood Body Fixing Brackets 7 2...

Page 5: ...bracket 7 1 as shown 109 5 mm from the vertical reference line and 190 mm above the horizontal reference line Mark the centres of the holes in the bracket Repeat this operation on the other side REAR...

Page 6: ...chimney using either a flexible or rigid pipe 150 or 125 mm the choice of which is left to the installer To install a 125 mm air exhaust connection insert the re ducer flange 9 on the hood body air ou...

Page 7: ...he 4 screws12c 2 9 x 9 5 supplied Lower chimney section Slightly widen the two sidesof the section and hook them be tween the upper section and the wall making sure that they are properly housed Fix t...

Page 8: ...s the operating speed of the extractor 1 Low speed used for a continuous and silent air change in the presence of light cooking vapour 2 Medium speed suitable for most operating conditions given the o...

Page 9: ...ers are not washable and cannot be regenerated and must be replaced approximately every 4 months of operation or more frequently with heavy usage REPLACING THE ACTIVATED CHARCOAL FILTER Remove the met...

Page 10: ......

Page 11: ......

Page 12: ...436005756_ver1...

Reviews: