9
Model
Cut-Out Width
M24AR
23
1
⁄
2
" (59.7cm)
M30AR
29
1
⁄
2
" (74.9cm)
M36AR
35
1
⁄
2
" (90.2cm)
24" (61cm)
22" (55.9cm)
78
1
⁄
2
" (199.4cm)
Minimum, typical
20"
(50.8cm)
minimum
Floor under product
MUST
be at or above the same level
of the surrounding finished floor, for ease of installation and
removal of unit
NOTE
Select Location
Locate the refrigerator in the coolest part of the room, out of
direct sunlight and away from heating ducts or registers.
Do not place the refrigerator next to heat-producing appli-
ances such as a range, oven or dishwasher. If this is not
possible, a section of cabinetry or an added layer of insula
-
tion between the two (2) appliances will help the refrigerator
operate more efficiently.
Do NOT install the refrigerator where the temperature will
drop below 60 degrees F (15 degrees C) or rise above 110
degrees F (43 degrees C). The compressor will NOT be
able to maintain proper temperatures.
PRE INSTALLATION CONSIDERATIONS
84
1
⁄
4
" to 84
7
⁄
8
"
(214cm) to (215.6cm)
"Cut out
width"
Figure 4
Table A
When planning your rough in opening a 3" removable filler
panel is recommended above the grille. To remove the
power module from the cabinet the front has to be tilted up
as shown in Figure 5 when removed for service.
Figure 5
-3" (7.6cm) removable filler
recommended
84
5
⁄
8
"
(214.9cm)
Maximum